Features | Usage | Can only be used in the EFI system network, e.g., with a Flexi Soft safety controller | Application | Indoor | Protective field range | 7 m | Collision protection field range | 15 m (on reference target) | Distance measuring range | 49 m | Number of simultaneously monitored protective fields | 2 | Type of field set | Triple field sets, dual field sets | Number of field sets | 16 | Number of fields | 32 | Number of monitoring cases | 32 | Scanning angle | 190° | Resolution (can be configured) | 30 mm, 40 mm, 50 mm, 70 mm, 150 mm | Angular resolution | 0.25° | Response time | 120 ms | Protective field supplement | 100 mm | Number of multiple samplings | 2 ... 16, configurable | Delay of automatic reset | 2 s ... 60 s, configurable |
|
Safety-related parameters | Type | Type 3 (IEC 61496) | Safety integrity level | SIL 2 (IEC 61508) | Category | Category 3 (EN ISO 13849) | Performance level | PL d (EN ISO 13849) | PFHD (mean probability of a dangerous failure per hour) | 8.0 x 10-8 | TM (mission time) | 20 years (EN ISO 13849) | Safe state in the event of a fault | At least one OSSD is in the OFF state. |
|
Functions | Restart interlock | ✔ | External device monitoring (EDM) | ✔ | Multiple sampling | ✔ | Monitoring case switching | ✔ | Simultaneous monitoring | ✔ | Static protective field switching | ✔ | Dynamic protective field switching | ✔ | Collision protection field | ✔ | Integrated configuration memory | ✔ | Measured data output | Expanded (CMS), via RS-422 | Safe SICK device communication via EFI | ✔ |
|
Interfaces | Connection type | System plug with or without connecting cable |
| Inputs | | External device monitoring (EDM) | 1 | Reset/restart | 1 | Static control inputs with EFI | 5 |
| Outputs | | OSSD pairs | 1 | Application diagnostic outputs | 3 |
| Configuration method | PC with CDS (Configuration and Diagnostic Software) | Configuration and diagnostics interface | RS-232 | Transmission rate | 9.6 kBaud, 19.2 kBaud, 38.4 kBaud |
| Data interface | RS-422 | Transmission rate | ≤ 500 kBaud |
| Safe SICK device communication via EFI | | Transmission rate | ≤ 500 kBaud | Length of cable | ≤ 50 m | Conductor cross section | 0.34 mm² |
|
|
Electrical data | Protection class | II (EN 50178) | Supply voltage Vs | 24 V DC (16.8 V DC ... 28.8 V DC) | Power consumption | ≤ 0.8 A ≤ 2.3 A | Outputs | | Output signal switching devices (OSSDs) | 2 x 500 mA | Application diagnostic outputs | 3 x 100 mA |
|
|
Mechanical data | Dimensions (W x H x D) | 155 mm x 185 mm x 160 mm | Weight | 3.3 kg | Housing material | Aluminum die cast | Housing color | RAL 1021 (yellow) | Front screen material | Polycarbonate | Front screen surface finish | Outside with scratch-resistant coating |
|
Ambient data | Enclosure rating | IP65 (EN 60529) | Ambient operating temperature | –10 °C ... +50 °C | Storage temperature | –25 °C ... +50 °C | Vibration resistance | IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 | Class | 5M1 (IEC 60721-3-5) |
| Shock resistance | IEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3 | Class | 5M1 (IEC 60721-3-5) | Continuous shock | 50 m/s², 11 ms | | 100 m/s², 16 ms |
|
|
Other information | Type of light | Pulsed laser diode | Wave length | 905 nm | Detectable remission factor | 1.8 % ... > 1,000 %, reflectors | Laser class | 1 (21 CFR 1040.10 and 1040.11, IEC 60825-1) |
|
Classifications | ECLASS 5.0 | 27272705 | ECLASS 5.1.4 | 27272705 | ECLASS 6.0 | 27272705 | ECLASS 6.2 | 27272705 | ECLASS 7.0 | 27272705 | ECLASS 8.0 | 27272705 | ECLASS 8.1 | 27272705 | ECLASS 9.0 | 27272705 | ECLASS 10.0 | 27272705 | ECLASS 11.0 | 27272705 | ECLASS 12.0 | 27272705 | ETIM 5.0 | EC002550 | ETIM 6.0 | EC002550 | ETIM 7.0 | EC002550 | ETIM 8.0 | EC002550 | UNSPSC 16.0901 | 39121528 |
|