SICK 1083738
SICKNot available

PAC50-FND

Pressure sensors: PAC50
Product Code: 1083738
Partner cod.: 1083738
SICK


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Tecnichal data
Features
MediumDry compressed air
Pressure typeGauge pressure
Pressure unitbar
Measuring range–1 bar ... 10 bar
Overpressure safety15 bar
Process temperature0 °C ... +60 °C
Analog signal output and ohmic load RA

Optional, 4 mA ... 20 mA / 0 V… 10 V. Automatic detection depending on connected load or programmable. Output signals can be inverted: 20 mA ... 4 mA / 10 V ... 0 V

Load resistance for current output < 600 Ohm

Load resistance with current output > 3 kOhm

Zero point adjustmentMax. + 5 % of span
Output signalIO-Link/PNP + PNP/NPN/Push-Pull
Diagnostics outputSwitching output 2 can be set as diagnostics output
Display

LCD with LED backlight (green/red), can be rotated electronically by 180°

Pressure display: 4 digits, 16 segments

Pressure unit in display can be switched: bar, MPa, kPa, psi and inHg

Update: 1,000, 500, 200, 100 ms (adjustable)

Initialization time300 ms
Mechanics/electronics
Process connection¼" NPT female 
Housing materialHousing: polycarbonate, Buttons: TPE, DIN rail mounting: POM, seals: NBR
Connection typeM12 round connector x 1, 4-pin
Supply voltage17 V DC ... 30 V DC
Power consumptionMax. 40 mA at L+ = 24 VDC
Electrical safety

Protection class: III

Overvoltage protection: 32 V DC

Short-circuit protection: QA, Q1, Q2 towards M and L+

Reverse polarity protection: L+ to M

CE-conformityEMC directive: 2004/108/EC, EN 61326-2-3
Weight sensorApprox. 40 g
Enclosure rating

IP65 

IP67 

Protection class III
RoHS certificate
cRUus certificate
MTTF243.01 years
Performance
Non-linearity≤ ± 0.5 %, of span (Best Fit Straight Line, BFSL) according to IEC 61298-2
Accuracy≤ ± 1.5 % of the span
Setting accuracy of switching outputs≤ ± 0.2 % of span
Non-repeatability≤ ± 0.2 % of the span
Rated temperature range+10 °C ... +60 °C
Ambient data
Ambient temperature0 °C ... +60 °C
Storage temperature–20 °C ... +80 °C
Relative humidity≤ 90 %
Shock loadMax. 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock)
Vibration loadMax. 5 g (10 ... 150 Hz), xyz, to DIN EN 60068-2-6
Classifications
eCl@ss 5.027200620
eCl@ss 5.1.427200620
eCl@ss 6.027200620
eCl@ss 6.227200620
eCl@ss 7.027200620
eCl@ss 8.027200620
eCl@ss 8.127200620
eCl@ss 9.027200620
eCl@ss 10.027200620
eCl@ss 11.027200620
eCl@ss 12.027200620
ETIM 5.0EC000243
ETIM 6.0EC000243
ETIM 7.0EC000243
ETIM 8.0EC000243
UNSPSC 16.090141112409