Features | Measurement principle | HDDM+ | Application | Outdoor | Light source | Infrared (850 nm) | Laser class | 1 (IEC 60825-1:2014, EN 60825-1:2014) | Aperture angle | | Horizontal | 270° |
| Scanning frequency | 15 Hz | Angular resolution | 0.33° | Working range | 0.05 m ... 25 m | Scanning range | | At 10% remission factor | 8 m |
|
|
Mechanics/electronics | Connection type | 1 x “Ethernet” connection, 4-pin M12 female connector 1 x connection “Power”, 12-pin, M12 male connector 1 x Micro USB female connector, type B | Supply voltage | 9 V DC ... 28 V DC | Power consumption | Typ. 4 W, 16 W with 4 max. loaded digital outputs | Output current | ≤ 100 mA | Housing color | Gray (RAL 7032) | Enclosure rating | IP67, applies only when the plastic cover of the “Aux interface” is closed (IEC 60529:1989+AMD1:1999+AMD2:2013) | Protection class | III (IEC 61140:2016-1) | Weight | 250 g, without connecting cables | Dimensions (L x W x H) | 60 mm x 60 mm x 86 mm | MTBF | > 100 years |
|
Safety-related parameters | |
Performance | Response time | 1 scan, typ. 67 ms 2 scans, ≤ 134 ms | Detectable object shape | Almost any | Systematic error | ± 60 mm | Statistical error | < 20 mm | Integrated application | Field evaluation with flexible fields Output of measurement data | Number of field sets | 16 field triples (48 fields, contour as reference; 1 triple (3 flexible fields) can be configured directly at the scanner) | Simultaneous evaluation cases | 3 simultaneous fields (per field set) |
|
Interfaces | | USB | ✔ | Remark | Micro USB | Function | Parameterization |
| Digital inputs | 4 (PNP, for field set switching) | Digital outputs | 3 (PNP, additional 1 x “Device Ready”) | Delay time | 67 ms ... 30,000 ms (configurable) | Dwell time | 67 ms ... 600,052 ms (configurable) | Optical indicators | 2 LEDs (ON, "device ready") |
|
Ambient data | Object remission | 4 % ... 1,000 % (reflectors) | Electromagnetic compatibility (EMC) | | Emitted radiation | Residential area (IEC 61000-6-3:2006+AMD1:2010) | Electromagnetic immunity | Industrial environment (IEC 61000-6-2:2005) |
| Vibration resistance | | Sine resonance scan | 10 Hz ... 1,000 Hz | Sine test | 10 Hz ... 500 Hz, 5 g, 10 frequency cycles | Noise test | 10 Hz ... 250 Hz, 4.24 g RMS, 5 h |
| Shock resistance | 50 g, 11 ms, ± 3 single shocks/axis 25 g, 6 ms, ± 1,000 continuous shocks/axis 50 g, 3 ms, ± 5,000 continuous shocks/axis | Ambient operating temperature | –25 °C ... +50 °C | Storage temperature | –40 °C ... +75 °C | Temperature change | –25 °C ... +50 °C, 10 cycles | Damp heat | +25 °C ... +55 °C, 95 % RH, 6 cycles | Permissible relative humidity | | Operation | < 80 %, Non-condensing (EN 60068-2-30:2005) | Storage | ≤ 90 %, Non-condensing (EN 60068-2-30:2005) |
| Ambient light immunity | 80,000 lx |
|
General notes | Note on use | The sensor does not constitute a safety component as defined by relevant legislation on machine safety. |
|
Classifications | ECLASS 5.0 | 27270990 | ECLASS 5.1.4 | 27270990 | ECLASS 6.0 | 27270913 | ECLASS 6.2 | 27270913 | ECLASS 7.0 | 27270913 | ECLASS 8.0 | 27270913 | ECLASS 8.1 | 27270913 | ECLASS 9.0 | 27270913 | ECLASS 10.0 | 27270913 | ECLASS 11.0 | 27270913 | ECLASS 12.0 | 27270913 | ETIM 5.0 | EC002550 | ETIM 6.0 | EC002550 | ETIM 7.0 | EC002550 | ETIM 8.0 | EC002550 | UNSPSC 16.0901 | 41111615 |
|