SICK


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Tecnichal data
Features
Sensor principleRFID
Locking principlePower to lock
CodingUniversally coded
Locking force Fmax
Flexible actuator4,100 N (EN ISO 14119)
Rigid actuator (frontal)3,630 N (EN ISO 14119)
Rigid actuator (lateral)3,510 N (EN ISO 14119)
Locking force FZh
Flexible actuator3,150 N (EN ISO 14119)
Rigid actuator (frontal)2,790 N (EN ISO 14119)
Rigid actuator (lateral)2,700 N (EN ISO 14119)
Actuation force20 N
Retaining force30 N
Force against which unlocking is possible≤ 25 N
Actuation frequency≤ 1 Hz
Approach speed≤ 20 m/min
Safety-related parameters
Safety integrity levelSIL 3 (IEC 61508)
CategoryCategory 4 (EN ISO 13849) 
Performance levelPL e (EN ISO 13849) 
PFHD (mean probability of a dangerous failure per hour)9.55 x 10-9 
TM (mission time)20 years (EN ISO 13849)
TypeType 4 (EN ISO 14119)
Actuator coding levelLow coding level (EN ISO 14119)
Safe state in the event of a faultAt least one safety-related semiconductor output (OSSD) is in the OFF state.
Functions
Switching behavior of the OSSDsLocking monitoring
Safe series connection

In control cabinet (with diagnostics)

With Flexi Loop (with diagnostics)

With T-connector (without diagnostics)

Interfaces
Connection typePlug connector, M12, 8-pin
Coupling nut materialStainless steel
Display elementsLEDs
Diagnostics indicator
Status display
Electrical data
Protection classIII (IEC 61140)
Contamination rating3 (IEC 60947-1)
Classification according to cULusClass 2
Usage categoryDC-13 (IEC 60947-5-3)
Rated insulation voltage Ui32 V
Rated impulse withstand voltage Uimp1,500 V
Supply voltage VS24 V DC (19.2 V DC ... 28.8 V DC)
Power consumption
Locking device unlocked65 mA
Locking device locked125 mA
Peak current800 mA, 200 ms
Type of outputSelf-monitoring semiconductor outputs (OSSDs)
Safety outputs2 PNP semiconductors, short-circuit protected, cross-circuit monitored
Output current
Safety outputs≤ 100 mA
Application diagnostic outputs≤ 50 mA
Output voltageUV - 2 V DC ... UV
Response time≤ 150 ms 
Release time≤ 350 ms 
Risk time150 ms 
Switch-on time3 s
Locking principlePower to lock
Mechanical data
Weight535 g
Material
HousingVISTAL®
Ball bracketStainless steel
Latch plate of the actuatorStainless steel
Plug connectorsStainless steel
Mechanical life1 x 106 switching cycles
Ambient data
Enclosure ratingIP65, IP67, IP69K (IEC 60529, IEC 60529, IEC 20653)
Ambient operating temperature–20 °C ... +55 °C
Storage temperature–25 °C ... +70 °C
Relative humidity10 % ... 95 %, at 40 °C (IEC 60068)
Vibration resistance10 Hz ... 55 Hz, 1 mm (IEC 60068-2-6)
Shock resistance30 g, 11 ms (EN 60068-2-27)
EMC

EN IEC 61326-3-1

EN IEC 60947-5-2

EN IEC 60947-5-3

EN 300330

Classifications
ECLASS 5.027272603
ECLASS 5.1.427272603
ECLASS 6.027272603
ECLASS 6.227272603
ECLASS 7.027272603
ECLASS 8.027272603
ECLASS 8.127272603
ECLASS 9.027272603
ECLASS 10.027272603
ECLASS 11.027272603
ECLASS 12.027272603
ETIM 5.0EC002593
ETIM 6.0EC002593
ETIM 7.0EC002593
ETIM 8.0EC002593
UNSPSC 16.090139122205