Industrial Automation

Mechatronics

Industrial Safety

Panel Components

Sensors and Systems of Vision

Pneumatics

Network Comunications

Automation Cables

Design Software

Access services

Enter your reserved area

Access services

Enter your reserved area

SICK 5322547
SICKNot available

LL3-TV06 LIGHT GUIDE HIGH TEMP

Fiber-optic sensors and fibers: LL3
Product Code: 5322547
Partner cod.: 5322547
SICK


Diminuisci la quantità
Aumenta la quantità
Tecnichal data
Technical Specs
Tecnichal data
Features
Device typeFibers
Functional principleThrough-beam system
Functional principle detailConsisting of a sender and a receiver
For fiber-optic sensorGLL170(T), WLL180, WLL24 Ex, WLL80
Fiber length2,000 mm
Fiber materialPolymethylmethacrylat (PMMA)
Jacket materialPolyethylen (PE)
Fiber head materialPolyamid (PA)
Outer diameter, fiber-optic cable connection2.2 mm
Fiber-optic cable cuttable
Thread diameter (housing)M4
Fiber-optic head designThreaded sleeve, 90° deflection
Angle of dispersion < 60°Yes
Compatibility with infrared light (1,450 nm)No
ApplicationHeat-resistant (≥100°C)
Highly flexible/elastic fibers (bend radius 1–4 mm)No
Adapter end sleeves requiredNo
Angle of dispersion18.18°
Integrated lensYes
Minimal object diameter0.4 mm 
Included with deliveryMounting, 2 x M4 hexagon nut, FC fiber cutter (5304141)
Compatibility tip adaptersNo
Special features90° deflection integrated, maximum sensing range
Mechanics/electronics
Bend radius, fibre-optic cable25 mm
Ambient operating temperature–40 °C ... +105 °C
Classifications
ECLASS 5.027270905
ECLASS 5.1.427270905
ECLASS 6.027270905
ECLASS 6.227270905
ECLASS 7.027270905
ECLASS 8.027270905
ECLASS 8.127270905
ECLASS 9.027270905
ECLASS 10.027270905
ECLASS 11.027270905
ECLASS 12.027270905
ETIM 5.0EC002651
ETIM 6.0EC002651
ETIM 7.0EC002651
ETIM 8.0EC002651
UNSPSC 16.090139121528
Sensing ranges with WLL80
Operating mode 16 µs245 mm
Operating mode 70 µs750 mm
Operating mode 250 µs1,150 mm
Operating mode 500 µs1,385 mm
Operating mode 1 ms1,560 mm
Operating mode 2 ms2,200 mm
Operating mode 8 ms3,180 mm
Sensing ranges with WLL180T
Operating mode 16 µs180 mm
Operating mode 70 µs550 mm
Operating mode 250 µs900 mm
Operating mode 2 ms2,100 mm
Operating mode 8 ms3,500 mm
NoteSensing ranges related to fiber-optic sensors with type of light: visible red light
Sensing ranges with GLL170
Operating mode 250 µs560 mm
Sensing ranges with GLL170T
Operating mode 50 µs460 mm
Operating mode 250 µs680 mm
Technical Specs
Unit weight30.000 Grams
Net unit weight30 Grams
Unit volume420 Cubic Centimetres (cm³)
Measurements15.000*2.000*14.000
Country of originJapan