Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

LEUZE 50106085
LEUZE 50106085
LEUZE 50106085
LEUZENon disponibile

HRTR 318K/66-120-S12

Diffuse sensor with background suppression
Cod. Articolo: 50106085
Cod. Fornitore: 50106085
LEUZE


Diminuisci la quantità
Aumenta la quantità
Specifiche
Specifiche
Basic dataSeries: 318
Operating principle: Diffuse reflection principle with background suppression
Optical dataOperating range: Guaranteed operating range
Operating range, white 90%: 0.001 ... 0.12 m
Operating range, gray 18%: 0.005 ... 0.11 m
Operating range, black 6%: 0.008 ... 0.1 m
Operating range limit: Typical operating range
Operating range limit, white 90%: 0.001 ... 0.14 m
Operating range limit, gray 18%: 0.005 ... 0.13 m
Operating range limit, black 6%: 0.008 ... 0.12 m
Beam path: Focused
Light source: LED, Red
Wavelength: 625 nm
LED group: 1
Type of light spot geometry: Rectangular
Focus: Fixed
Electrical dataProtective circuit: Polarity reversal protection
Short circuit protected
Transient protection
Performance data
Supply voltage UB: 10 ... 30 V, DC, Incl. residual ripple
Residual ripple: 0 ... 10 %, From UB
Open-circuit current: 0 ... 25 mA
Outputs
Number of digital switching outputs: 2 Piece(s)
Switching output 1: Array
Switching output 2: Array
Time behaviorSwitching frequency: 1,000 Hz
Response time: 0.5 ms
Readiness delay: 100 ms
ConnectionConnection 1
Function: Signal OUT
Voltage supply
Type of connection: Connector
Thread size: M12
Type: Male
Material: Plastic
No. of pins: 4 -pin
Encoding: A-coded
Mechanical dataThread size: M18 x 1 mm
Dimension (∅ x L): 18 mm x 50 mm
Housing material: Plastic
Plastic housing: PA 12
Lens cover material: Plastic
Net weight: 20 g
Housing color: Black
Red
Operation and displayType of display: LED
Operational controls: 270° potentiometer
Environmental dataAmbient temperature, operation: -25 ... 65 °C
Ambient temperature, storage: -40 ... 70 °C
CertificationsDegree of protection: IP 67
Protection class: II
Certifications: c UL US
Standards applied: IEC 60947-5-2