LEUZE 50112139
LEUZE 50112139
LEUZE 50112139
LEUZENon disponibile

PRK 2/42D

Polarized retro-reflective photoelectric sensor
Cod. Articolo: 50112139
Cod. Fornitore: 50112139
LEUZE


Diminuisci la quantità
Aumenta la quantità
Specifiche
Specifiche
Basic dataSeries: 2
Operating principle: Reflection principle
Application: Detection of small parts
Optical dataOperating range: Guaranteed operating range
Operating range limit: 0.07 ... 4 m, With reflector TK(S) 100x100
Beam path: Divergent
Light source: LED, Red
Wavelength: 640 nm
LED group: 1
Light spot size [at sensor distance]: 5 mm [200 mm]
Type of light spot geometry: Round
Electrical dataProtective circuit: Overvoltage protection
Polarity reversal protection
Short circuit protected
Transient protection
Performance data
Supply voltage UB: 10 ... 30 V, DC
Residual ripple: 0 ... 10 %, From UB
Open-circuit current: 0 ... 20 mA
Outputs
Number of digital switching outputs: 2 Piece(s)
Switching output 1: Array
Switching output 2: Array
Time behaviorSwitching frequency: 700 Hz
Response time: 0.72 ms
Readiness delay: 120 ms
ConnectionConnection 1
Function: Signal OUT
Voltage supply
Type of connection: Cable
Cable length: 2,000 mm
Sheathing material: PVC
Cable color: Black
Number of conductors: 4 -wire
Wire cross section: 0.14 mm²
Mechanical dataDimension (W x H x L): 8 mm x 23.1 mm x 12 mm
Housing material: Plastic
Plastic housing: TPE
Lens cover material: Plastic/PC
Net weight: 50 g
Housing color: Red, RAL 3000
Type of fastening: Through-hole mounting
Operation and displayType of display: LED
Environmental dataAmbient temperature, operation: -30 ... 55 °C
Ambient temperature, storage: -30 ... 75 °C
CertificationsDegree of protection: IP 67
Protection class: III
Certifications: cUR us
Standards applied: IEC 60947-5-2