Basic data | Series: BPS 300i |
Functions | Functions: Heating |
Characteristic parameters | MTTF: 83 years |
Optical data | Depth of field: 50 ... 170 mm Light source: Laser, Red Laser class: 1, in accordance with IEC 60825-1:2014 (EN 60825-1:2014) Transmitted-signal shape: Continuous Light beam exit: Lateral |
Measurement data | Measurement range: 0 ... 10,000,000 mm Reproducibility (1 sigma): 0.05 mm Measurement value output: 1 ms Max. traverse rate: 10 m/s |
Electrical data | Performance data Supply voltage UB: 18 ... 30 V, DC Power consumption, max.: 17.7 W Inputs/outputs selectable Number of inputs/outputs selectable: 2 Piece(s) Switching element: Transistor, PNP |
Interface | Type: PROFIBUS DP PROFIBUS DP Function: Process |
Service interface | Type: USB USB Function: Configuration via GSD modules Service |
Mechanical data | Design: Cubic Dimension (W x H x L): 100 mm x 108.7 mm x 48.3 mm Housing material: Metal Lens cover material: Glass Net weight: 580 g Type of fastening: Dovetail grooves Fastening on back Via optional mounting device |
Operation and display | Type of display: LED Monochromatic graphic display, 128 x 32 pixels |
Environmental data | Ambient temperature, operation: -35 ... 50 °C Ambient temperature, storage: -35 ... 70 °C Relative humidity (non-condensing): 90 % |
Certifications | Degree of protection: IP 65, EN 60529 with various connectors or screwed-on caps Protection class: III Certifications: c UL US Test procedure for EMC in accordance with standard: EN 61000-6-2 EN 61000-6-3 Test procedure for shock in accordance with standard: IEC 60068-2-27, test Ea Test procedure for continuous shock in accordance with standard: IEC 60068-2-29, test Eb Test procedure for vibration in accordance with standard: IEC 60068-2-6, test Fc |