IS 230FM/4NO.5-10E

Inductive switch
Cod. Articolo: 50128164
Cod. Fornitore: 50128164
LEUZE


Diminuisci la quantità
Aumenta la quantità
Specifiche
Specifiche
Basic dataSeries: 230
Typ. operating range limit Sn: 10 mm
Operating range Sa: 0 ... 8.1 mm
Special versionSpecial version: Reduction factor 1
Electrical dataProtective circuit: Inductive protection
Polarity reversal protection
Short circuit protected
Performance data
Supply voltage UB: 10 ... 30 V, DC
Residual ripple: 0 ... 20 %, From UB
Open-circuit current: 0 ... 10 mA
Temperature drift, max. (in % of Sr): 10 %, Over the entire operating temperature range
Repeatability, max. (in % of Sr): 5 %, For UB = 20 … 30 V DC, ambient temperature Ta = 23 °C ± 5 °C
Switching hysteresis: 15 %
Outputs
Number of digital switching outputs: 1 Piece(s)
Switching outputs: Array
Switching output 1: Array
Time behaviorSwitching frequency: 50 Hz
Readiness delay: 50 ms
ConnectionNumber of connections: 1 Piece(s)
Connection 1
Function: Signal OUT
Voltage supply
Type of connection: Cable
Cable length: 2,000 mm
Sheathing material: PUR
Cable color: Black
Number of conductors: 3 -wire
Wire cross section: 0.34 mm²
Mechanical dataDesign: Cylindrical
Thread size: M30 x 1.5 mm
Dimension (∅ x L): 30 mm x 50 mm
Type of installation: Embedded
Housing material: Stainless steel
Stainless steel housing: V2A
Sensing face material: Stainless steel, AISI 303
Net weight: 190 g
Housing color: Silver
Type of fastening: Mounting thread
Via optional mounting device
Standard measuring plate: 30 x 30 mm², Fe360
Operation and displayType of display: LED
Number of LEDs: 1 Piece(s)
Environmental dataAmbient temperature, operation: -25 ... 70 °C
CertificationsDegree of protection: IP 68
IP 69K
Certifications: c UL US
Test procedure for EMC in accordance with standard: IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
Standards applied: IEC 60947-5-2
Correction factorsAluminum: 1
Stainless steel: 0.6
Copper: 0.8
Brass: 1.3
Fe360 steel: 1