LEUZE 50133744
LEUZE 50133744
LEUZE 50133744
LEUZENon disponibile

PRK3CL1.A3/LP

Polarized retro-reflective photoelectric sensor
Cod. Articolo: 50133744
Cod. Fornitore: 50133744
LEUZE


Diminuisci la quantità
Aumenta la quantità
Specifiche
Specifiche
Basic dataSeries: 3C
Operating principle: Reflection principle
Special versionSpecial version: Autocollimation
Optical dataOperating range: Guaranteed operating range
Operating range limit: 0 ... 3 m, With reflector MTKS 50x50.1
Beam path: Collimated
Light source: Laser, Red
Wavelength: 655 nm
Laser class: 1, in accordance with IEC 60825-1:2014 (EN 60825-1:2014)
Light spot size [at sensor distance]: 3 mm [1,000 mm]
Type of light spot geometry: Round
Shift angle: Typ. ± 2°
Electrical dataProtective circuit: Polarity reversal protection
Short circuit protected
Performance data
Supply voltage UB: 10 ... 30 V, DC, Incl. residual ripple
Residual ripple: 0 ... 15 %, From UB
Open-circuit current: 0 ... 15 mA
Outputs
Number of digital switching outputs: 2 Piece(s)
Switching output 1: Array
Switching output 2: Array
Time behaviorSwitching frequency: 3,000 Hz
Response time: 0.17 ms
Readiness delay: 300 ms
InterfaceType: IO-Link
IO-Link
COM mode: COM2
Min. cycle time: COM2 = 2.3 ms
Specification: V1.1
SIO-mode support: Yes
ConnectionConnection 1
Function: Signal IN
Signal OUT
Voltage supply
Type of connection: Cable
Cable length: 2,000 mm
Sheathing material: PUR
Cable color: Black
Number of conductors: 4 -wire
Wire cross section: 0.2 mm²
Mechanical dataDimension (W x H x L): 11.4 mm x 34.2 mm x 18.3 mm
Housing material: Plastic
Plastic housing: PC-ABS
Lens cover material: Plastic / PMMA
Net weight: 50 g
Housing color: Red
Type of fastening: Through-hole mounting
Via optional mounting device
Compatibility of materials: ECOLAB
Operation and displayType of display: LED
Operational controls: Teach button
Function of the operational control: Sensitivity adjustment
Environmental dataAmbient temperature, operation: -10 ... 55 °C
Ambient temperature, storage: -40 ... 70 °C
CertificationsDegree of protection: IP 67
IP 69K
Protection class: III
Certifications: c UL US
Standards applied: IEC 60947-5-2