Basic data | Series: RSL 400 Application: Mobile danger zone guarding Mobile side guarding Stationary access guarding Stationary danger zone guarding
|
Functions | Functions: Data output, configurable Four-field mode PROFIsafe Restart: Start/restart interlock (RES), selectable
|
Characteristic parameters | Type: 3, IEC/EN 61496 SIL: 2, IEC 61508 SILCL: 2, IEC/EN 62061 Performance Level (PL): d, EN ISO 13849-1 PFHD: 9E-08 per hour Mission time: 20 years, EN ISO 13849-1 Category: 3, EN ISO 13849
|
Protective field data | Resolution (adjustable): 30/40/50/60/70/150 mm Minimum adjustable range: 50 mm Number of field pairs, switchable: Up to 100 Number of quads, switchable: 50 Number of protective functions: 4 Piece(s) Number of independent sensor configurations: Up to 10 Diffuse reflection, min.: 1.8 % Operating range: 0 ... 8.25 m
|
Warning field data | Number of field pairs: Up to 100 Operating range: 0 ... 20 m Object size: 150 mm x 150 mm Diffuse reflection, min.: 10 %
|
Optical data | Light source: Laser, Infrared Wavelength: 905 nm Laser class: 1, IEC/EN 60825-1:2014 Transmitted-signal shape: Pulsed Repetition frequency: 90 kHz Angular resolution: 0.1 ° Scanning angle: 270 °
|
Electrical data | Protective circuit: Overvoltage protection Performance data Supply voltage UB: 24 V, DC, -30 ... 20 % Current consumption (without load), max.: 900 mA, (use power supply unit with 3 A) Power consumption, max.: 22 W, For 24 V, plus output load
|
Time behavior | Response time: 80 ms, ≥
|
Interface | Type: PROFINET PROFINET Function: Process PROFINET device: Device acc. to Spec V2.3.4 GSDML: GSDML acc. to Spec V2.3.2 Profile: PROFINET/PROFIsafe Conformance class: C Network load class: III Security level: 1 Switch functionality: IRT-ready 2-port switch acc. to IEEE 802, integrated in connection unit Port properties: Auto-Crossover Auto-Negotiation Auto-Polarity I&M: 0 - 4 Supported topologies: MRP client SNMP Safety-related switching signals: 4 Piece(s)
|
Service interface | Type: Bluetooth, Ethernet, USB Ethernet Function: Configuration/parametization TCP/IP Connection: M12 connector, 4-pin, D-coded Bluetooth Function: Configuration/parametization Frequency band: 2,400 ... 2,483.5 MHz Radiated transmitting power: Max. 4.5 dBm (2.82 mW), class 2 USB Function: Configuration/parametization Connection: USB 2.0 mini-B, socket Transmission speed, max.: 12 Mbit/s Cable length: ≤ 5m Longer cable lengths are possible using active cables.
|
Connection | Number of connections: 3 Piece(s) Connection 1 Function: Voltage supply Type of connection: Connector Thread size: M12 Type: Male Material: Metal No. of pins: 4 -pin Encoding: A-coded Connection 2 Function: PROFINET/PROFIsafe communication, input Type of connection: Connector Thread size: M12 Type: Female Material: Metal No. of pins: 4 -pin Encoding: D-coded Connection 3 Function: PROFINET/PROFIsafe communication, output Type of connection: Connector Thread size: M12 Type: Female Material: Metal No. of pins: 4 -pin Encoding: D-coded
|
Mechanical data | Dimension (W x H x L): 140.2 mm x 170 mm x 142 mm Housing material: Metal Plastic Metal housing: Diecast zinc Lens cover material: Plastic/PC Net weight: 4,300 g Housing color: Yellow, RAL 1021 Type of fastening: Mounting plate Through-hole mounting Via optional mounting device
|
Operation and display | Type of display: Alphanumerical display LED indicator Number of LEDs: 11 Piece(s) Type of configuration: Software Sensor Studio Operational controls: Software Sensor Studio
|
Environmental data | Ambient temperature, operation: 0 ... 50 °C Ambient temperature, storage: -20 ... 60 °C Relative humidity (non-condensing): 15 ... 95 %
|
Certifications | Degree of protection: IP 65 Protection class: III, EN 61140 Certifications: TÜV Süd Test procedure for EMC in accordance with standard: DIN 40839-1/3 EN 61496-1 Test procedure for oscillation in accordance with standard: EN 60068-2-6 Test procedure for continuous shock in accordance with standard: IEC 60068-2-29 US patents: US 7,656,917 B US 7,696,468 B US 8,520,221 B US 10,304,307B
|