Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

LEUZE 547952
LEUZE 547952
LEUZE 547952
LEUZE 547952
LEUZENon disponibile

MSI-SR5B-01

Safety relay
Cod. Articolo: 547952
Cod. Fornitore: 547952
LEUZE


Diminuisci la quantità
Aumenta la quantità
Specifiche
Specifiche
Basic dataSeries: MSI-SR5B
Application: E-Stop circuits
Optoelectronic protective devices
Position switches (mechanical contacts)
Solenoid switches (reed contacts, equivalent)
Transponder switches (OSSD outputs)
FunctionsFunctions: Contactor monitoring (EDM)
Cross circuit monitoring
Double sensor monitoring
Start/restart interlock (RES)
Restart: Automatic
Manual
Characteristic parametersSIL: 3, IEC 61508
SILCL: 3, IEC/EN 62061
Performance Level (PL): e, EN ISO 13849-1
MTTFd: 73 years, EN ISO 13849-1
PFHD: 1E-08 per hour
PFHD, nop = 4800: 0.00000001 per hour
PFHD, nop = 28800: 0.00000002 per hour
PFHD, nop = 86400: 0.00000005 per hour
Mission time: 20 years, EN ISO 13849-1
Category: 4, EN ISO 13849-1
STOP category: 0, IEC/EN 60204-1
B10d at AC1 (ohmic load): 400,000 number of cycles
B10d at DC13 (inductive load): 4,000,000 number of cycles
Electrical dataProtective circuit: Fuse on switching output, upstream
Switching frequency, max.: 3600 switching cycles/h
Continuous current per current path, max.: 2 A
Input current, max.: 150 mA
External safeguarding for supply circuit: 200 mA delay-action
External contact fuse protection per current path: 5 A quick-action, or 3.15 A delay-action
Permissible input line resistance, max.: 30 Ω
Performance data
Supply voltage UB: 24 V, DC, -20 ... 20 %
Current consumption, max.: Without external load
Power consumption, max.: 4.8 W, For 24 V, plus output load
Outputs
Number of safety-related switching outputs (OSSDs): 2 Piece(s)
Safety-related switching outputs: Array
Safety-related switching output 1: Array
Safety-related switching output 2: Array
Output circuit
Number of outputs, safety-oriented, undelayed, contact-based: 2 Piece(s)
Number of outputs, safety-oriented, delayed, contact-based: 0 Piece(s)
Number of outputs, signaling function, undelayed, contact-based: 0 Piece(s)
Max. thermal continuous current Ith, release current paths: 6 A
Time behaviorPickup delay, automatic start: 350 ms
Pickup delay, manual start: 50 ms
Regression delay: 10 ms
Test pulse acceptance, max.: 1 ms
Time window between 2 channels of a sensor, max.: 60 ms
ConnectionNumber of connections: 1 Piece(s)
Connectible safety sensors (AOPDs): Up to 2 AOPDs type 4, type 3 or type 2 self-testing
Connectible electro-mechanical safety devices: E-Stop command devices, 1 and 2-channel
Safety switches
Connection 1
Function: Connection to device
Type of connection: Terminal
Type of terminal: Screw terminal
No. of pins: 16 -pin
Cable properties
Connection cross sections: 0.2 to 2.5 mm²
Mechanical dataDimension (W x H x L): 22.5 mm x 99 mm x 114.1 mm
Housing material: Plastic
Plastic housing: PA 66
Net weight: 170 g
Housing color: Gray
Type of fastening: Snap-on mounting
Mechanical life time: 10,000,000 actuation cycles
Operation and displayType of display: LED
Number of LEDs: 4 Piece(s)
Environmental dataAmbient temperature, operation: 0 ... 55 °C
Ambient temperature, storage: -25 ... 70 °C
Relative humidity (non-condensing): 0 ... 95 %
CertificationsDegree of protection: IP 20 (terminals)
IP 40 (housing)
Protection class: II
Certifications: TÜV Süd
c UL US
US patents: US 6,418,546 B