Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

LEUZE 549954
LEUZE 549954
LEUZE 549954
LEUZE 549954
LEUZE 549954
LEUZENon disponibile

MSI-MD-FBX

Muting interface
Cod. Articolo: 549954
Cod. Fornitore: 549954
LEUZE


Diminuisci la quantità
Aumenta la quantità
Specifiche
Specifiche
Basic dataSeries: MSI-MD-FB
Application: Muting interface for muting applications in combination with standard variants of the MLC and ELC safety light curtains, as well as MLD multiple light beam safety devices
FunctionsFunctions: Muting-timeout extension
Muting enable function
Timing controlled 2-sensor muting
Restart: Automatic
Manual
Characteristic parametersSIL: 3, IEC 61508
SILCL: 3, IEC/EN 62061
Performance Level (PL): e, EN ISO 13849-1
PFHD: 2.5E-09 per hour
Mission time: 20 years, EN ISO 13849-1
Category: 4, EN ISO 13849-1
Electrical dataProtective circuit: Overvoltage protection
Polarity reversal protection
Short circuit protected
Performance data
Supply voltage UB: 24 V, DC, -20 ... 20 %, Compensation necessary at 20 ms voltage dip, min. 250 mA (+ external loads)
Current consumption, max.: 150 mA, Without external load
Power consumption, max.: 3.6 W, For 24 V, plus output load
Residual ripple: -5 ... 5 %, From UB
Inputs
Number of safety-related switching inputs: 2 Piece(s)
Number of digital switching inputs: 8 Piece(s)
Switching inputs: Array
Digital switching input 1: Array
Digital switching input 2: Array
Digital switching input 3: Array
Digital switching input 4: Array
Digital switching input 5: Array
Safety-related switching inputs: Array
Outputs
Number of safety-related switching outputs (OSSDs): 2 Piece(s)
Number of digital switching outputs: 3 Piece(s)
Safety-related switching outputs: Array
Safety-related switching output 1: Array
Safety-related switching output 2: Array
Switching outputs: Array
Switching output 1: Array
Switching output 2: Array
Switching output 3: Array
Time behaviorRestart delay time: 100 ms
Regression delay: 5 ms
ConnectionNumber of connections: 8 Piece(s)
Connection 1
Function: Machine interface
Type of connection: Connector
Thread size: M12
Type: Male
Material: Metal
No. of pins: 8 -pin
Connection 2
Function: Connection - safety sensor
Type of connection: Connector
Thread size: M12
Type: Female
Material: Metal
No. of pins: 5 -pin
Connection 3
Function: Connection - muting indicator
Type of connection: Connector
Thread size: M12
Type: Female
Material: Metal
No. of pins: 5 -pin
Connection 4
Function: Connection - acknowledgment unit
Type of connection: Connector
Thread size: M12
Type: Female
Material: Metal
No. of pins: 5 -pin
Connection 5
Function: Connections for four muting sensors
Type of connection: Connector
Thread size: M12
Type: Female
Material: Metal
No. of pins: 5 -pin
Connection 6
Function: Service interface
Type of connection: USB
Connector type: USB 2.0 Micro-B
Cable properties
Permissible conductor cross section, typ.: 0.25 mm²
Length of connection cable, max.: 50 m
Mechanical dataDimension (W x H x L): 60 mm x 38.3 mm x 225 mm
Net weight: 560 g
Housing color: Yellow
Type of fastening: Mounting plate
Mounting plate with L-angle
Through-hole mounting
Operation and displayType of display: LED
Number of LEDs: 14 Piece(s)
Operational controls: DIP switch
Function of the operational control: Selection of operating mode
Environmental dataAmbient temperature, operation: -30 ... 60 °C
Ambient temperature, storage: -40 ... 70 °C
Relative humidity (non-condensing): 0 ... 95 %
CertificationsDegree of protection: IP 67
Protection class: III
Certifications: TÜV Süd
c UL US
Test procedure for oscillation in accordance with standard: IEC/EN 60068-2-6
Shock resistance: 100 m/s²
Test procedure for shock in accordance with standard: IEC/EN 60068-2-6
US patents: US 6,418,546 B