AXL F AI2 AO2 XC 1H - Analog module

AxiolineF, Analog I/O module, Analog inputs: 2, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection technology: 2-conductor, Analog outputs: 2, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, Extremeconditions version, degree of protection: IP20, including bus base module and AxiolineF connectors
Cod. Articolo: 1035429
Cod. Fornitore: 1035429
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/172c7c5767999646b422d3edebda44f8/-S204x204-FJPG
Width: 35 mm
Height: 126.1 mm
Depth: 54 mm
Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
InterfacesAxiolineFlocal bus
Number of interfaces: 2
Connection method: Bus base module
Transmission speed: 100 Mbps
System propertiesModule
Input address area: 4 Byte
Output address area: 4 Byte
Required parameter data: 11 Byte
Required configuration data: 7 Byte
Input dataAnalog
Input name: Analog inputs
Description of the input: Differential inputs, voltage or current can be chosen separately
Number of inputs: 2
A/D conversion time: 2 µs
A/D converter resolution: 16 bit
Connection method: Push-in connection
Connection technology: 2-conductor
Note regarding the connection technology: shielded, twisted pair
Current input signal: 0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA
Input resistance current input: 104 Ω (typical)
Voltage input signal: 0 V ... 5 V
-5 V ... 5 V
0 V ... 10 V
-10 V ... 10 V
Input resistance of voltage input: 268 kΩ (typical)
Data formats: IB IL, S7-compatible, standardized representation
Input filter: 30 Hz, 12 kHz and mean-value generation (can be parameterized)
Limit frequency (3 dB): 30 Hz
12 kHz
Common mode voltage range signal - ground: -50 VDC ... 50 VDC
Measured value representation: 16 bits (15 bits + sign bit)
Protective circuit: Transient protection of inputs; Suppressor diode
Overload protection of the current inputs; No; ±5.2VDC, maximum, Imax = 50mA
Overload protection of the voltage inputs; ±30 V DC, maximum
Output dataAnalog
Output name: Analog outputs
Connection method: Push-in connection
Connection technology: 2-conductor
Note regarding the connection technology: shielded, twisted pair
Number of outputs: 2
D/A converter resolution: 16 bit
Protective circuit: Short-circuit and overload protection; electronic
Transient protection; Suppressor diode
Data formats: IB IL, S7-compatible, standardized representation
Representation of output values: 16 bits (15 bits + sign)
Process data update: 150 µs
Current output signal: 0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA
Load/output load current output: ≤ 500 Ω
Voltage output signal: 0 V ... 5 V
-5 V ... 5 V
0 V ... 10 V
-10 V ... 10 V
Load/output load voltage output: ≥ 2 kΩ
Product propertiesType: block modular
Product type: I/O component
Product family: AxiolineF
Mounting position: any (no temperature derating)
Scope of delivery: including bus base module and AxiolineF connectors
Insulation characteristics
Overvoltage category: II (IEC 60664-1, EN60664-1)
Pollution degree: 2 (IEC 60664-1, EN60664-1)
Electrical propertiesPotentials
Power consumption: typ. 1.56 W (at UBus and UA)
max. 2.67 W (at UBus and UA)
Potentials: AxiolineF local bus supply (U
Supply voltage: 5 VDC (via bus base module)
Current draw: max. 150 mA
typ. 120 mA
Power consumption: max. 0.75 W
typ. 0.6 W
Potentials: Supply for analog modules (U
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 80 mA (2 current channels, 24mA output, 500Ω load)
typ. 40 mA
max. 60 mA (2 voltage channels, 10V output, 2kΩ load)
Power consumption: max. 1.92 W
Protective circuit: Surge protection; electronic (35 V, 0.5 s)
Reverse polarity protection; Polarity protection diode
Transient protection; Suppressor diode
Electrical isolation/isolation of the voltage ranges
Test voltage: 5V supply of the local bus (UBus) / 24V supply (I/Os): 500 VAC, 50 Hz, 1 min.
Test voltage: 5 V supply of the local bus (UBus) / analog inputs and outputs: 500 VAC, 50 Hz, 1 min.
Test voltage: 5V supply of the local bus (UBus) / functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O) / analog inputs and outputs: 500 VAC, 50 Hz, 1 min.
Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: Analog inputs and outputs/functional ground: 500 VAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: AxiolineF connector
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Applications with UL approval: only use copper conductors.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
AxiolineF connector
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Applications with UL approval: only use copper conductors.
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C (Standard applications and applications with UL approval)
-40°C ... 70°C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: DIN rail mounting
Mounting position: any (no temperature derating)
Specifiche
ECLASSECLASS-11.0: 27242601
ECLASS-12.0: 27242601
ECLASS-13.0: 27242601
ETIMETIM 9.0: EC001596
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01195.pdf

Approvals_01758.pdf

Approvals_01935.pdf

Data_sheet_00248.pdf

Manual_00006.pdf

Manual_00007.pdf

Manufacturer_declaration_00789.pdf

Manufacturer_declaration_02156.pdf

Manufacturer_declaration_05480.pdf

Manufacturer_declaration_05562.pdf

Manufacturer_declaration_05563.pdf

Package_slip_00672.pdf

Product_information_00028.pdf

Product_information_00033.pdf

Technical_drawing_06195.pdf

Various_00004.pdf