PHOENIX CONTACT 1051328
PHOENIX CONTACTNon disponibile

RFC 4072S - Safety controller

PLCnext Control with 4 x 10/100/1000 Ethernet, PROFINET controller with integrated PROFIsafe safety controller, PROFINET device, IP20 degree of protection, pluggable parameterization memory
Cod. Articolo: 1051328
Cod. Fornitore: 1051328
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
Product propertiesType: Stand-Alone
Product type: Controller
Product family: PLCnext Control
Insulation characteristics
Protection class: III (IEC 61140, EN61140, VDE0140-1)
Pollution degree: 2 (when installed in a control cabinet or housing with IP54 degree of protection or higher)
Display
Diagnostics display: yes
System propertiesProcessor: Intel® Core™ i5-6300U 2x 2.4 GHz (Standard)
Arm® Cortex®-A9, 800 MHz (CPU1)
Arm® Cortex®-A8, 600 MHz (CPU2)
Retentive data storage: 2 Mbyte
IEC 61131 runtime system
Program memory: 16 Mbyte
Data storage system: 32 Mbyte
PROFINET
Device function: PROFINET controller, PROFINET device
Update rate: min. 1 ms
Conformance Class: B
Number of supported devices: max. 256
Vendor ID: 00B0hex / 176dez
Function
Diagnostics display: yes
Controller redundancy: No
Safety function: yes
Functionality
Programming languages supported: Symbolic flowchart (SFC)
Ladder diagram (LD)
Function block diagram (FBD)
Structured text (ST)
C++
C#
Java
Python
Simulink
System requirements
Engineering tool: PLCnext Engineer
Eclipse
Visual Studio
MATLAB® Simulink®
Application interface: OPCUA
Electrical propertiesPower consumption: typ. 25 W (Without fan module)
max. 35 W (With fan module)
Maximum power dissipation for nominal condition: max. 24 W
Supply
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (including ripple (3.6VPP))
Power supply connection: Screw terminal blocks, plug-in
Typical current consumption: 1 A
Real-time clock
Realtime clock: integrated (capacitive buffering)
Description realtime clock: 1.73 s/day = 20ppm at 25°C
Connection dataCOMBICON connector
Conductor cross section, rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12
InterfacesWeb server: yes
USB
Number of interfaces: 1
Connection method: USB type A, male connector
Ethernet
Bus system: RJ45
Number of interfaces: 4
Connection method: RJ45 jack
Note on the connection method: Auto negotiation and auto crossing, auto polarity exchange
Transmission speed: 10/100/1000 Mbps (LAN 1/LAN 2, half duplex or full duplex)
10/100 Mbps (LAN3.1/LAN3.2 (internally switched), half duplex or full duplex)
DimensionsExternal dimensions
Width / Height / Depth: 122 mm / 182 mm / 173 mm (without fan module)
122 mm / 220 mm / 173 mm (With fan module)
CharacteristicsSafety data: ENISO13849
Category: max. 4
Performance level (PL): max. e
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL): max. 3
Safety data: ENIEC 62061
Safety Integrity Level Claim Limit (SIL CL): max. 3
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20 (Manufacturers declaration, not evaluated by UL)
Ambient temperature (operation): 0°C ... 60°C up to 2000m above mean sea level (from 40°C only with fan module)
0°C ... 55°C 2000m...3000m above mean sea level (With fan module only)
0°C ... 50°C 3000m...4000m above mean sea level (With fan module only)
Ambient temperature (storage/transport): -25°C ... 70°C
Permissible humidity (operation): 10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Shock (operation): 20g (in accordance with EN60068-2-27/IEC 60068-2-27)
Shock (storage/transport): 20g (in accordance with EN60068-2-27/IEC 60068-2-27)
Vibration (operation): 1g (in accordance with EN60068-2-6/IEC 60068-2-6)
Vibration (storage/transport): 1g (in accordance with EN60068-2-6/IEC 60068-2-6)
Air pressure (operation): 60 kPa ... 108 kPa (up to 4000m above mean sea level)
Air pressure (storage/transport): 58 kPa ... 108 kPa (up to 4500m above mean sea level)
Resistance to gases that may endanger the functions, in acc. with DIN 40046-36, DIN 40046-37: Use of the device in these ambient conditions is prohibited.
EMC dataConformance with EMC directives: Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Electrostatic discharge (ESD)EN61000-4-2/IEC 61000-4-2 Criterion B, 6 kV contact discharge, 8 kV air discharge
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Electromagnetic fieldsEN61000-4-3/IEC 61000-4-3 Criterion A, Field intensity: 10 V/m
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Fast transients (burst)EN61000-4-4/IEC 61000-4-4 Criterion B; Supply lines: 2 kV; Signal/data lines: 2 kV
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Transient overvoltage (surge)EN61000-4-5/IEC 61000-4-5 Criterion B, supply lines: 0.5kV, signal/data cables: 1kV
Immunity test in accordance with EN61000-6-2/IEC 61000-6-2 Conducted interferenceEN61000-4-6/IEC 61000-4-6 Criterion A, Test voltage 10 V
Noise emission test in accordance with EN61000-6-4/IEC 61000-6-4
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
MountingMounting type: DIN rail mounting
Specifiche
ECLASSECLASS-11.0: 27242207
ECLASS-12.0: 27242207
ECLASS-13.0: 27242207
ETIMETIM 9.0: EC000236
UNSPSCUNSPSC 21.0: 32151700
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00176.pdf

Application_note_00183.pdf

Application_note_00110.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Certification_00098.pdf

Certification_00099.pdf

Certification_00365.pdf

Certification_00366.pdf

Manual_00031.pdf

Manufacturer_declaration_01120.pdf

Manufacturer_declaration_06043.pdf

Package_slip_02185.pdf

Technical_drawing_06713.pdf

Technical_drawing_06714.pdf