PHOENIX CONTACT 1079557
PHOENIX CONTACT 1079557
PHOENIX CONTACTNon disponibile

HC-COM-Q4/2-I-AT/PT-F - Contact insert

Contact insert, number of positions: 4+2+PE, size: COM, power contacts: 4, control contacts: 2, number of connections per position: 1, Socket, Axial screw connection, 400 V, 40 A, 2.5 mm2...6 mm2, application: Power/signal
Cod. Articolo: 1079557
Cod. Fornitore: 1079557
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
NotesGeneral: Connectors may be operated only when there is no load/voltage.
MountingAssembly instructions: To ensure correct use, installation in housing with IP54 protection or better is required
Note regarding axial connection technology:
Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.
Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.
The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.
Assembly instructions
Before assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Hexagonal socket: WAF 2
Product propertiesType: COM
Product type: Contact insert with a fixed no. of positions
Number of positions: 6
Connection profile: 4+2+PE
Contact numbering: 1 - 4 (power contacts)
11 - 12 (control contacts)
Application: Power/signal
Number of connections per position: 1
No. of power contacts: 4
No. of control contacts: 2
Contact material type: turned
Series: HC-COM
Insulation characteristics
Overvoltage category: III
Degree of pollution: 3
DimensionsDimensional drawing: https://caas.production.phoenixcontact.coremedia.cloud/caas/v1/stable/media/22514/full/b250?format=jpg
Width: 22.5 mm
Height: 48 mm
Length: 42 mm
Mechanical characteristics
Contact diameter: 4 mm
Connection dataConnection technology
Connection technology: Axial screw connection (power contacts)
Push-in connection (control contacts)
Number of connections per position: 1
Connection in acc. with standard: IEC / EN
Conductor connection
Conductor cross section: 2.5 mm² ... 6 mm² (power contacts)
0.34 mm² ... 1.5 mm² (Control contacts, applies to flexible conductors with ferrules)
Connection cross section AWG: 14 ... 10 (power contacts)
22 ... 16 (Control contacts, applies to flexible conductors with ferrules)
Tightening torque: 1.5 Nm ... 1.8 Nm (2,5mm² ... 6,0mm²)
Stripping length of the individual wire: 9 mm +1mm (Power)
8 mm (Signal)
Electrical propertiesRated voltage (III/3): 400 V (Phase-ground power contacts)
250 V (control contacts)
690 V (Phase-phase power contacts)
Rated voltage for power contacts: 400/690 V
250
Rated surge voltage: 6 kV (Phase-phase power contacts)
4 kV (control contacts)
Rated current: 40 A (power contacts)
10 A (control contacts)
Mechanical propertiesMechanical data
Insertion/withdrawal cycles: ≥ 500
Material specificationsFlammability rating according to UL 94: V0
Contact material: Copper alloy
Contact surface material: Ag (alternatively Au)
Contact carrier material: PC
Material of contact surface, power contact: Ag
Material of contact surface, control contact: Ag (alternatively Au)
Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3)
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -40°C ... 125°C (including heating up of contacts)
Standards and regulationsTesting
Standards/regulations: PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DINEN45545-2 (Risk level HL1 - HL3)
Specifiche
ECLASSECLASS-11.0: 27440205
ECLASS-12.0: 27440205
ECLASS-13.0: 27440205
ETIMETIM 9.0: EC000438
UNSPSCUNSPSC 21.0: 39121500