Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 1079655
PHOENIX CONTACTNon disponibile

BP 4-3CT - Short-circuit connector

Plug for three current transformers, each with leading transformer short circuit
Cod. Articolo: 1079655
Cod. Fornitore: 1079655
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
Product propertiesProduct type: Plug
Number of positions: 6
Number of connections: 6
Number of rows: 1
Potentials: 6
Insulation characteristics
Overvoltage category: III
Degree of pollution: 3
Electrical propertiesRated surge voltage: 4 kV
Maximum power dissipation for nominal condition: 1.02 W
Connection dataNominal cross section: 4 mm²
Rated cross section AWG: 10
Screw thread: M4
Tightening torque: 1.2 ... 1.5 Nm
Stripping length: 8 mm ... 9 mm
Connection in acc. with standard: IEC 61984
Conductor cross section rigid: 0.5 mm² ... 2.5 mm²
Cross section AWG: 20 ... 14 (converted acc. to IEC)
Conductor cross section flexible: 0.5 mm² ... 2.5 mm²
Conductor cross section, flexible [AWG]: 20 ... 14 (converted acc. to IEC)
Flexible conductor cross section (ferrule with plastic sleeve): 0.5 mm² ... 2.5 mm²
Nominal current: 15 A
Maximum load current: 30 A
Nominal voltage: 320 V
DimensionsWidth: 60.1 mm
Height: 40 mm
Depth: 57.3 mm
Material specificationsColor: gray
Flammability rating according to UL 94: V0
Insulating material group: I
Insulating material: PA
Static insulating material application in cold: -60°C
Relative insulation material temperature index (Elec., UL 746 B): 130°C
Fire protection for rail vehicles (DIN EN 45545-2) R22: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24: HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26: HL 1 - HL 3
Surface flammability NFPA 130 (ASTM E 162): passed
Specific optical density of smoke NFPA 130 (ASTM E 662): passed
Smoke gas toxicity NFPA 130 (SMP 800C): passed
Mechanical propertiesMechanical data
Open side panel: No
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -60°C ... 105°C (max. short-term operating temperature RTI Elec.)
Ambient temperature (storage/transport): -25°C ... 60°C (for a short time, not exceeding 24h, -60°C to +70°C)
Ambient temperature (assembly): -5°C ... 70°C
Ambient temperature (actuation): -5°C ... 70°C
Permissible humidity (storage/transport): 30 % ... 70 %
Standards and regulationsConnection in acc. with standard: IEC 61984
MountingMounting type: Insertion in base strip
Specifiche
ECLASSECLASS-11.0: 27141120
ECLASS-13.0: 27250304
ETIMETIM 9.0: EC000897
UNSPSCUNSPSC 21.0: 39121400
Descrizione
Plug for three current transformers, each with leading transformer short circuit
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Safety_notes_00001.pdf

Technical_drawing_07770.pdf