Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 1086945
PHOENIX CONTACT 1086945
PHOENIX CONTACTNon disponibile

PSR-PC21-2NO-2NC-24DC-SC - Coupling relay

Coupling relay for SIL3 high and low-demand applications, coupled digital output signals to the I/O, 2independently controllable enabling current paths, 2confirmation current paths, safe state off applications, test pulse filter, pluggable screw terminal block
Cod. Articolo: 1086945
Cod. Fornitore: 1086945
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
NotesUtilization restriction
CCCex note: Use in potentially explosive areas is not permitted in China.
Product propertiesProduct type: Coupling relay
Product family: PSRmini
Application: Safe switch off
High demand
Low demand
Ex
Mechanical service life: 10x 106 cycles
Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN61810-3
Times
Typ. starting time with Us: < 70 ms (when controlled via A1 or A3 at US)
Typical release time: < 30 ms (when controlled via A1 or A3 at US)
Recovery time: 500 ms
Electrical propertiesMaximum power dissipation for nominal condition: 7.05 W (S1, S2, S3, S4 = ON, 2-channel load, UB=30V, US=24V, IS=2*46mA, IL²=36A, Rcontact=0.05Ω)
Nominal operating mode: 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 VAC
Rated surge voltage/insulation: Safe isolation, reinforced insulation 6.4kV from (A1/A2, A3/A4, 21/22, 41/42) to (13/14, 33/34) and between (13/14) and (33/34)
Basic insulation 4kV between all current paths and housing
500 V isolation between (A1/A2, A3/A4) and (21/22, 41/42)
Supply
Designation: A1/A2, A3/A4
Rated control circuit supply voltage US: 19.2 VDC ... 30 VDC
24 VDC -20%/+25%
Rated control supply current IS: typ. 15 mA (per channel (configurable))
typ. 25 mA (per channel (configurable))
typ. 40 mA (per channel (configurable))
typ. 46 mA (per channel (configurable))
Power consumption at US: typ. 360 mW (per channel (configurable))
typ. 600 mW (per channel (configurable))
typ. 960 mW (per channel (configurable))
typ. 1.1 W (per channel (configurable))
Inrush current: typ. 200 mA (Δt=10µs at Us, per channel (configurable))
typ. 300 mA (Δt=10µs at Us, per channel (configurable))
Filter time: 2 ms (in the event of voltage dips at Us)
Protective circuit: Serial protection against polarity reversal; 38.6 V suppressor diode
Output dataRelay: Enabling current paths (13/14, 33/34)
Output description: 2 N/O contacts parallel, without delay, safety-related, floating
Number of outputs: 2
Contact switching type: 2 enabling current paths
Contact material: AgSnO2
Switching voltage: min. 12 VDC
max. 250 V AC/DC (Observe the load curve)
Switching capacity: min. 60 mW
Inrush current: min. 3 mA
max. 6 A
Switching capacity in accordance with IEC 60947-5-1: 4 A (24V (DC13))
5 A (230 V (AC15))
Limiting continuous current: 6 A (High demand)
4 A (Low demand)
Sq. Total current: 72 A2 (High-demand, observe derating)
32 A2 (Low-demand, observe derating)
Switching frequency: 1 Hz
Mechanical service life: 10x 106 cycles
Output fuse: 6 A gL/gG
4 A gL/gG (for low-demand applications)
Relay: Confirmation current paths (21/22, 41/42)
Output description: 2 N/C contacts parallel, without delay, safety-related, floating
Number of outputs: 2
Contact switching type: 2 confirmation current paths
Contact material: AgCuNi, + Au
Switching voltage: min. 5 VDC
max. 30 VDC
Switching capacity: min. 20 mW
Inrush current: min. 1 mA
max. 100 mA
Limiting continuous current: 100 mA
Switching frequency: 1 Hz
Mechanical service life: 10x 106 cycles
Output fuse: 150 mA Fast-blow
Connection dataConductor connection
Connection method: Screw connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG: 24 ... 12
Stripping length: 7 mm
Screw thread: M3
Tightening torque: 0.6 Nm
SignalingStatus display: 2 x green LEDs
DimensionsWidth: 12.5 mm
Height: 112.2 mm
Depth: 114.5 mm
Material specificationsHousing material: Polyamide
CharacteristicsSafety data
Stop category: 0
Safety data: ENISO13849
Category: 4
Performance level (PL): e
Safety data: EN50156-2
Safety Integrity Level (SIL): 3 (Reference IEC 61508)
Safety data: IEC 61508 – High-demand for 2-channel wiring (1oo2 structure)
Safety Integrity Level (SIL): 3
Safety data: IEC 61508 – High-demand for 1-channel wiring (1oo1 structure)
Safety Integrity Level (SIL): 2
Safety data: IEC 61508 – Low-demand for 2-channel wiring (1oo2 structure)
Safety Integrity Level (SIL): 3
Safety data: IEC 61508 – Low-demand for 1-channel wiring (1oo1 structure)
Safety Integrity Level (SIL): 2
Safety data: ENIEC 62061
Safety Integrity Level (SIL): 3
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -40°C ... 70°C (observe derating)
Ambient temperature (storage/transport): -40°C ... 85°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
Shock: 15g
Vibration (operation): 10Hz...150Hz, 2g
ApprovalsATEX
Identification: II3GExecnCIICT4Gc
Certificate: DEMKO 19 ATEX 2240X
IECEx
Identification: ExecnCIICT4Gc
Certificate: IECEx ULD 19.0023X
UL, USA/Canada
Identification: cULus
Certificate: E140324
UL Ex, USA / Canada
Identification: Class I, Zone 2, AEx ec nC IIC T4 / Ex ec nC IIC Gc T4 X
Class I, Div. 2, Groups A, B, C, D, T4
Certificate: E360692
CE
Identification: CE-compliant
Environmental simulation test
Identification: G3
Certificate: ISA-S71.04
CCC/China-Ex
Identification: Ex ec nC IIC T4 Gc
Certificate: 2022122304115696
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: EN61010-1, EN60947-1, EN60079-7, EN60079-15
MountingMounting type: DIN rail mounting
Assembly instructions: See derating curve
Mounting position: vertical or horizontal
Connection method: Screw connection
Specifiche
ECLASSECLASS-11.0: 27371819
ECLASS-12.0: 27371819
ECLASS-13.0: 27371819
ETIMETIM 9.0: EC001449
UNSPSCUNSPSC 21.0: 39122200
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00694.pdf

Approvals_00695.pdf

Approvals_00731.pdf

Approvals_01204.pdf

Approvals_01205.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Certification_00180.pdf

Data_sheet_00542.pdf

Manufacturer_declaration_01273.pdf

Manufacturer_declaration_02277.pdf

Manufacturer_declaration_05474.pdf

Manufacturer_declaration_06277.pdf

Package_slip_01999.pdf

Technical_drawing_08009.pdf