AXL SE RTD4 PT100 - Temperature module

Axioline SmartElements, Temperature recording module, Analog RTD inputs: 4 (Pt100), connection technology: 3-conductor, degree of protection: IP20
Cod. Articolo: 1088106
Cod. Fornitore: 1088106
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://caas.production.phoenixcontact.coremedia.cloud/caas/v1/stable/media/22530/full/b250?format=jpg
Width: 14.9 mm
Height: 62.2 mm
Depth: 62 mm
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
InterfacesSmartElement interface
Number of interfaces: 1
Connection method: Card edge connector
Transmission speed: See system in which you use the SmartElement.
Start time until ready to operate: < 1000 ms
System propertiesModule
ID code (hex): none
Process data channel: 64 bit
Input address area: 8 Byte
Output address area: 8 Byte
Required parameter data: 24 Byte
Required configuration data: 6 Byte
Input dataAnalog
Input name: Analog RTD inputs
Description of the input: Inputs for resistive temperature sensors
Number of inputs: 4 (Pt100)
Connection method: Push-in connection
Connection technology: 3-conductor
Note regarding the connection technology: shielded, 2-, 3-, and 4-conductor sensors can be connected
A/D converter resolution: 16 bit
Sensor types (RTD) that can be used: Pt 100 (IEC 60751/EN 60751)
Data formats: Standardized representation
Measured value representation: 16 bits (15 bits + sign bit)
Nominal value of the current sources: 1 mA (pulsed current, the data is valid during the sampling phase)
Process data update: typ. 1 ms
Protective circuit: Overload protection; max. ±40VDC, 1 min.
Transient protection
Product propertiesType: modular
Product type: I/O component
Product family: Axioline SmartElements
Mounting position: See the system in which the SmartElement is used.
Insulation characteristics
Overvoltage category: II (IEC 60664-1)
Pollution degree: 2 (EN60664-1)
Electrical propertiesPotentials: Communications power supply of the Smart Elements (U
Supply voltage: using card edge connectors
Potentials: I/O supply (U
Supply voltage: 24 VDC (using card edge connectors)
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 12 mA
typ. 8 mA
Current consumption: min. 5 mA (without connected peripherals)
Power consumption: max. 290 mW
min. 120 mW
Protective circuit: Surge protection; See the system in which the SmartElement is used.
Reverse polarity protection; Polarity protection diode
Electrical isolation/isolation of the voltage ranges
Test voltage: Communications supply / 24 V supply (I/O): 500 VAC, 50 Hz, 1 min.
Test voltage: Communications supply / functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: I/O
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineSmartElements” user manual.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm²
Stripping length: 8 mm
I/O
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineSmartElements” user manual.
Conductor cross section, rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm²
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: Smart Element slot
Mounting position: See the system in which the SmartElement is used.
Specifiche
ECLASSECLASS-11.0: 27242601
ECLASS-12.0: 27242601
ECLASS-13.0: 27242601
ETIMETIM 9.0: EC001596
UNSPSCUNSPSC 21.0: 32151600
Descrizione
Axioline Smart Elements, Temperature recording module, Analog RTD inputs: 4 (Pt 100), connection method: 3-wire, degree of protection: IP20
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00139.pdf

Approvals_01798.pdf

Approvals_01799.pdf

Approvals_01938.pdf

Approvals_01945.pdf

Approvals_01952.pdf

Approvals_01953.pdf

Data_sheet_00553.pdf

Manual_00006.pdf

Manual_00045.pdf

Manual_00007.pdf

Manufacturer_declaration_01400.pdf

Manufacturer_declaration_02364.pdf

Manufacturer_declaration_04371.pdf

Manufacturer_declaration_06292.pdf

Product_information_00033.pdf

Product_information_01034.pdf

Technical_drawing_08037.pdf