AXL SE INC1 SYM - Special function module

Axioline SmartElements, Position detection module, Incremental encoder input:1, symmetrical encoders, in accordance with EIA-422, Digital inputs:2, 24 VDC, degree of protection:IP20
Cod. Articolo: 1088130
Cod. Fornitore: 1088130
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://caas.production.phoenixcontact.coremedia.cloud/caas/v1/stable/media/22530/full/b250?format=jpg
Width: 14.9 mm
Height: 62.2 mm
Depth: 62 mm
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
InterfacesSmartElement interface
Number of interfaces: 1
Connection method: Card edge connector
Transmission speed: See system in which you use the SmartElement.
Start time until ready to operate: < 500 ms
System propertiesModule
ID code (hex): none
Process data channel: 80 bit
Input address area: 10 Byte
Output address area: 10 Byte
Required parameter data: 19 Byte
Required configuration data: 7 Byte
Input dataDigital
Input name: Digital inputs
Description of the input: EN 61131-2, type 3
Number of inputs: 2 (DI Ref, DI L)
Connection method: Push-in connection
Connection technology: 1-conductor
Input voltage range "0" signal: -3 VDC ... 5 VDC
Input voltage range "1" signal: 11 VDC ... 30 VDC
Nominal input voltage UIN: 24 VDC
Nominal input current at UIN: 3 mA
Protective circuit: Transient protection; Suppressor diode
Encoder
Number of inputs: 1 (A, /A, B, /B, Z, /Z)
Input name: Incremental encoder input
Encoder signals: symmetrical encoders, in accordance with EIA-422
Cable length: max. 30 m (Shielded cable)
Product propertiesType: modular
Product type: I/O component
Product family: Axioline SmartElements
Mounting position: See the system in which the SmartElement is used.
Insulation characteristics
Overvoltage category: II (IEC 60664-1, EN60664-1)
Pollution degree: 2 (IEC 60664-1, EN60664-1)
Electrical propertiesEncoder
Number: 1 (+5V)
1 (+24V)
1 (A, /A, B, /B, Z, /Z)
Nominal output voltage: 5 VDC
24 VDC
Voltage range: 5 VDC ... 5.5 VDC
19.2 VDC ... 30 VDC
Current carrying capacity: max. 250 mA
max. 500 mA
Protective circuit: Short-circuit protection; Electrical and thermal
Overload protection
Transient protection; Suppressor diode
Short-circuit protection; Electrical (from approx. 600mA)
Overload protection
Transient protection; Suppressor diode
Designation: Symmetrical incremental encoders
Signal voltage level: Differential signal (signal – inverted signal), in accordance with EIA-422
Common mode voltage range signal - ground: -20 VDC ... 20 VDC
Input frequency: max. 1 MHz
Potentials: Communications power supply of the Smart Elements (U
Supply voltage: using card edge connectors
Potentials: I/O supply (U
Supply voltage: 24 VDC (using card edge connectors)
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 700 mA
typ. 512 mA
Current consumption: min. 11 mA (without connected peripherals)
Power consumption: max. 21 W (of which 1.55W internal losses)
min. 264 mW
Protective circuit: Surge protection; See the system in which the SmartElement is used.
Reverse polarity protection; Polarity protection diode
Electrical isolation/isolation of the voltage ranges
Test voltage: Communications supply / 24 V supply (I/O): 500 VAC, 50 Hz, 1 min.
Test voltage: Communications supply / functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: I/O
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineSmartElements” user manual.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm²
Stripping length: 8 mm
I/O
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineSmartElements” user manual.
Conductor cross section, rigid: 0.25 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.25 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm²
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: Smart Element slot
Mounting position: See the system in which the SmartElement is used.
Specifiche
ECLASSECLASS-11.0: 27242605
ECLASS-12.0: 27242605
ECLASS-13.0: 27242605
ETIMETIM 9.0: EC001601
UNSPSCUNSPSC 21.0: 32151600
Descrizione
Axioline Smart Elements, Position detection module, Incremental encoder input: 1, symmetrical encoders, in accordance with EIA-422, Digital inputs: 2, 24 V DC, degree of protection: IP20
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00139.pdf

Approvals_01798.pdf

Approvals_01799.pdf

Data_sheet_00559.pdf

Manual_00006.pdf

Manual_00045.pdf

Manual_00007.pdf

Manufacturer_declaration_01401.pdf

Manufacturer_declaration_02464.pdf

Manufacturer_declaration_04371.pdf

Manufacturer_declaration_06298.pdf

Technical_drawing_08043.pdf