Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 1088850
PHOENIX CONTACT 1088850
PHOENIX CONTACTNon disponibile

UNO-PS/1AC/12DC/ 55W/H - Power supply unit

Primary-switched UNO POWER power supply for DIN rail mounting, input: 1-phase, output: 12 V DC/55 W
Cod. Articolo: 1088850
Cod. Fornitore: 1088850
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
Input dataAC operation
Nominal input voltage range: 100 VAC ... 240 VAC
Input voltage range: 85 VAC ... 264 VAC
Input voltage range AC: 85 VAC ... 264 VAC
Voltage type of supply voltage: AC
Inrush current: < 30 A (typical)
Inrush current integral (I2t): < 0.5 A2s
Frequency range (fN): 50 Hz ... 60 Hz ±10%
Mains buffering time: > 20 ms (120VAC)
> 90 ms (230 V AC)
Current consumption: 1.3 A (100VAC)
0.6 A (240VAC)
Nominal power consumption: 127 VA
Protective circuit: Transient surge protection; Varistor
Power factor (cos phi): 0.49
Typical response time: < 1 s
Input fuse: 2 A (slow-blow, internal)
Recommended breaker for input protection: 6 A ... 16 A (Characteristics B, C, D, K)
Output dataEfficiency: typ. 87 % (120VAC)
typ. 88 % (230 V AC)
Nominal output voltage: 12 VDC ±1%
Nominal output current (IN): 4.6 A (-25°C...55°C)
Derating: 55°C ... 70°C (2.5%/K)
Feedback voltage resistance: < 25 VDC
Protection against overvoltage at the output (OVP): ≤ 25 VDC
Control deviation: < 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple: < 30 mVPP (with nominal values)
Output power: 55 W
Maximum no-load power dissipation: < 0.3 W
Power loss nominal load max.: < 8 W
Rise time: < 0.5 s (UOUT (10 % ... 90 %))
Response time: < 2 ms
Connection in parallel: yes, for redundancy and increased capacity
Connection in series: yes
Connection dataInput
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 14
Stripping length: 8 mm
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Output
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 2.5 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 2.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 14
Stripping length: 8 mm
Screw thread: M3
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
SignalingTypes of signaling: LED
Electrical propertiesNumber of phases: 1.00
Product propertiesProduct type: Power supply
Product family: UNO POWER
MTBF (IEC 61709, SN 29500): > 865000 h (40°C)
Insulation characteristics
Protection class: II (in closed control cabinet)
Degree of pollution: 2
DimensionsWidth: 35 mm
Height: 90 mm
Depth: 84 mm
Installation dimensions
Installation distance right/left: 0 mm / 0 mm
Installation distance top/bottom: 30 mm / 30 mm
MountingMounting type: DIN rail mounting
Assembly instructions: alignable: 0mm horizontally, 30mm vertically
Mounting position: horizontal DIN rail NS 35, EN 60715
With protective coating: No
Material specificationsFlammability rating according to UL94 (housing / terminal blocks): V0
Housing material: Plastic
Polycarbonate
Foot latch material: POM (Polyoxymethylene)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C (> 55°C Derating: 2.5 %/K)
Ambient temperature (storage/transport): -40°C ... 85°C
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): ≤ 95 % (at 25°C, non-condensing)
Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Standards and regulationsStandard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations: EN50178/VDE0160 (PELV)
Standard – Limitation of mains harmonic currents: EN61000-3-2
Standard - Electrical safety: IEC 62368-1(SELV)
Standard – Safety extra-low voltage: IEC 62368-1 (SELV) und EN60204-1 (PELV)
Standard - Safe isolation: DINVDE0100-410
Standard - Safety of transformers: EN61558-2-16
Approval - requirement of the semiconductor industry with regard to mains voltage dips: EN61000-4-11
ApprovalsCSA: CAN/CSA-C22.2 No.60950-1-07
CSA-C22.2 No.107.1-01
CAN/CSA-C22.2 No. 213 Class I, Division 2, Groups A, B, C, D T4A (Hazardous Location)
UL approvals: UL/C-UL listed UL508
UL/C-UL Listed ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D T4A (Hazardous Location)
UL/C-UL Recognized UL60950-1
Conformity/Approvals
SIL in accordance with IEC 61508: 0
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise immunity: EN61000-6-2
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: 6 kV (Test Level 3)
Discharge in air: 8 kV (Test Level 3)
Comments: Criterion A
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 1 GHz
Test field strength: 10 V/m (Test Level 3)
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: 4 kV (Test Level 4 - asymmetrical)
Output: 2 kV (Test Level 3 - asymmetrical)
Comments: Criterion A
Surge voltage load (surge)
Standards/regulations: EN61000-4-5
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Input/Output: asymmetrical
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V (Test Level 3)
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Specifiche
ECLASSECLASS-11.0: 27040701
ECLASS-13.0: 27040701
ECLASS-12.0: 27040701
ETIMETIM 9.0: EC002540
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00722.pdf

Approvals_01431.pdf

Approvals_01432.pdf

Manufacturer_declaration_03183.pdf

Manufacturer_declaration_04490.pdf

Manufacturer_declaration_06313.pdf

Manufacturer_declaration_18207.pdf

Package_slip_02517.pdf

Product_information_00057.pdf

Technical_drawing_08123.pdf

Various_00030.pdf

Various_00006.pdf