Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 1104983
PHOENIX CONTACTDisponibile

PSR-M-EF6-SDOR4-PI - Extension module

Safe extension module with 4safe relay outputs, 4reset inputs, TBUS interface, up to SIL3, Cat.4/PLe, pluggable Push-in terminal block, TBUS connector included
Cod. Articolo: 1104983
Cod. Fornitore: 1104983
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
Product propertiesProduct type: Safety device
Application: Safe shutdown
Insulation characteristics
Protection class: III
Times
Response time: see user manual
Restart time: min. 5 s (Boot time)
max. 10 s (Boot time)
Electrical propertiesMaximum power dissipation for nominal condition: 7.07 W
Nominal operating mode: 100% operating factor
Interfaces: DIN rail TBUS for connection to the master module, supplied as standard
Air clearances and creepage distances
Rated insulation voltage: 250 VAC
Rated surge voltage/insulation: Basic insulation 4 kV between all current paths and housing
Supply
Designation: A1/A2
Rated control circuit supply voltage US: 19.2 VDC ... 28.8 VDC
24 VDC -20%/+20% (external fuse, typically 4A)
Rated control supply current IS: typ. 120 mA
Power consumption at US: typ. 2.88 W
Inrush current: 2 A (Δt=1ms at Us)
Filter time: typ. 5 ms (at A1 in the event of voltage dips at Us)
Protective circuit: Serial protection against polarity reversal
Input dataDigital: Reset inputs (FBK1, FBK2, FBK3, FBK4)
Description of the input: IEC 61131-2 type 3
Number of inputs: 4
Input voltage range "0" signal: 0 VDC ... 5 VDC
Input voltage range "1" signal: 11 VDC ... 28.8 VDC
Input current range "0" signal: < 1 mA
Filter time: 250 ms ±2ms (Test pulse rate>500ms)
Cable length: max. 100 m (per input)
Max. permissible overall conductor resistance: 1.2 kΩ (Input and reset circuit at US)
Current consumption: typ. 10 mA (typically with US)
max. 13 mA (at a control voltage of 28.8VDC)
Output dataRelay: Enabling current paths (13_NO1/14_NO1,23_NO2/24_NO2,33_NO3/34_NO3,43_NO4/44_NO4)
Output description: safety-related N/O contacts
Number of outputs: 4 (1 NO per output)
Contact switching type: 4 safe outputs
Switching voltage: min. 10 V AC/DC
max. 250 V AC/DC (Observe the load curve)
Switching capacity: min. 200 mW
Inrush current: min. 20 mA
max. 6 A
Switching capacity in accordance with IEC 60947-5-1: 3 A (250V (AC15))
2 A (24V (DC13))
Limiting continuous current: 4 A (observe derating)
Sq. Total current: 64 A2 (for 4xsingle-channel,observe derating)
32 A2 (for 2xtwo-channel,observe derating)
Switching frequency: 0.5 Hz
Mechanical service life: 40x 106 switching cycles
Output fuse: 4 A gL/gG
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG: 24 ... 16
Stripping length: 10 mm
SignalingStatus display: 4xLED (yellow)
4 x LED (green, yellow, red)
1 x LED (green), 2 x LED (orange)
Operating voltage display: 1 x green LED
Error indication: 2xLED (red)
DimensionsWidth: 22.61 mm
Height: 107.74 mm
Depth: 113.6 mm
Material specificationsColor: yellow
Housing material: Polyamide PA non-reinforced
CharacteristicsSafety data
Stop category: 0
Safety data: ENISO13849
Performance level (PL): e (2-channel wiring)
c (1-channel wiring)
Safety data: IEC 61508 - High-demand for 2-channel wiring
Safety Integrity Level (SIL): 3
Safety data: IEC 61508 - High-demand for 1-channel wiring
Safety Integrity Level (SIL): 1
Safety data: ENIEC 62061
Safety Integrity Level (SIL): 3 (2-channel wiring)
1 (1-channel wiring)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -10°C ... 55°C (observe derating)
Ambient temperature (storage/transport): -20°C ... 85°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 95 % (non-condensing)
Max. permissible relative humidity (operation): 95 % (non-condensing)
Shock: 10g for Δt=16ms (continuous shock, 1000 shocks in each space direction)
Vibration (operation): 10Hz...150Hz, amplitude 0.15mm, 2g
ApprovalsCE
Identification: CE-compliant
MountingMounting type: DIN rail mounting
Assembly instructions: Observe derating
Mounting position: vertical or horizontal
Connection method: Push-in connection
Specifiche
ECLASSECLASS-11.0: 27371819
ECLASS-13.0: 27371819
ECLASS-12.0: 27371819
ETIMETIM 9.0: EC001449
UNSPSCUNSPSC 21.0: 39122200
Descrizione
Safe extension module with 4 safe relay outputs, 4 reset inputs, TBUS interface, up to SILCL 3, cat. 4/PL e, SIL 3, pluggable Push-in terminal block, TBUS connector included
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00901.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Certification_00224.pdf

Certification_00318.pdf

Data_sheet_00644.pdf

Manual_00057.pdf

Manual_00058.pdf

Manufacturer_declaration_01347.pdf

Manufacturer_declaration_02191.pdf

Manufacturer_declaration_05475.pdf

Technical_drawing_08535.pdf