TRIO-PS-2G/1500DC/24DC/1.5 - Power supply unit

Primary-switched TRIO POWER DC/DC converter with Push-in connection for DIN rail mounting, input: 1,500VDC, output: 24VDC / 1.5A
Cod. Articolo: 1107892
Cod. Fornitore: 1107892
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
Input dataDC operation
Nominal input voltage range: 500 VDC ... 1500 VDC
Input voltage range: 450 VDC ... 1650 VDC
Wide-range input: no
Electric strength, max.: ≤ 1800 VDC 1 s
Typical national grid voltage: 500 VDC
1500 VDC
Voltage type of supply voltage: DC
Inrush current integral (I2t): typ. 0.15 A2s
Current consumption: typ. 85 mA (450 V DC)
typ. 30 mA (1500VDC)
Recommended breaker for input protection: 2 A (1500VDC)
Output dataEfficiency: typ. 88 % (500 V DC)
typ. 87 % (900VDC)
typ. 83 % (1500VDC)
Nominal output voltage: 24 VDC ±3%
Nominal output current (IN): 1.5 A
Derating: > 60°C ... 70°C (2.5%/K)
Feedback voltage resistance: ≤ 35 VDC
Protection against overvoltage at the output (OVP): ≤ 30 VDC
Control deviation: < 1 % (change in load, static 10 % ... 90 %)
< 3 % (Dynamic load change 10 % ... 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple: < 40 mVPP (Ripple)
< 50 mVPP (Noise)
Short-circuit-proof: yes
No-load proof: yes
Output power: 36 W
Maximum no-load power dissipation: < 1.1 W (500VDC)
< 1.4 W (900VDC)
< 2.4 W (1500VDC)
Power loss nominal load max.: < 4.2 W (500VDC)
< 5.5 W (900VDC)
< 7.5 W (1500VDC)
Rise time: ≤ 30 ms (UOUT (10 % ... 90 %))
Connection in parallel: yes, for redundancy and increased capacity
Connection in series: No
Connection dataInput
Connection method: Push-in connection
Conductor cross section, rigid min.: 1 mm²
Conductor cross section, rigid max.: 4 mm²
Conductor cross section flexible min.: 1 mm²
Conductor cross section flexible max.: 2.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.: 1 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.: 2.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.: 1 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.: 2.5 mm²
Conductor cross section AWG min.: 18
Conductor cross section AWG max.: 12
Stripping length: 10 mm
Output
Connection method: Push-in connection
Conductor cross section, rigid min.: 1 mm²
Conductor cross section, rigid max.: 4 mm²
Conductor cross section flexible min.: 1 mm²
Conductor cross section flexible max.: 2.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.: 1 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.: 2.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.: 1 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.: 2.5 mm²
Conductor cross section AWG min.: 18
Conductor cross section AWG max.: 12
Stripping length: 10 mm
SignalingTypes of signaling: LED
Signal output: LED status indicator
Signalization designation: DC OK
Status display: "DC OK" LED green
Note on status display: UOUT > 21.5 V: LED lights up
Color: green
DC OK: UOUT > 0.9 x UN (UN = 24VDC)
Electrical propertiesNumber of phases: 1.00
Insulation voltage input/output: 4.2 kV DC (type test)
2.6 kV DC (routine test)
Product propertiesProduct type: DC/DC converters
Product family: TRIO POWER
MTBF (IEC 61709, SN 29500): > 3300000 h (25°C)
> 1760000 h (40°C)
> 740000 h (60°C)
Insulation characteristics
Protection class: II
Degree of pollution: 2
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3fd681ea4335214b842689c454daf9d0/-S204x204-FJPG
Width: 48 mm
Height: 130 mm
Depth Device depth (DIN rail mounting): 115 mm (Device depth (DIN rail mounting))
Installation dimensions
Installation distance right/left: 0 mm / 0 mm
Installation distance top/bottom: 50 mm / 50 mm
MountingMounting type: DIN rail mounting
Assembly instructions: alignable: horizontally 0 mm (≤ 40°C) 10 mm (≤ 70°C), vertically 50 mm
Mounting position: horizontal DIN rail NS 35, EN 60715
With protective coating: No
Material specificationsFlammability rating according to UL94 (housing / terminal blocks): V0
Housing material: Plastic
Type of housing: Polycarbonate
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C (>60°C Derating: 2,5%/K)
Ambient temperature (storage/transport): -40°C ... 85°C
Maximum altitude: ≤ 4000 m (>2000m, Derating: 10%/1000m)
Max. permissible relative humidity (operation): ≤ 95 % (at 25°C, non-condensing)
Shock: 11ms, 15g, in each space direction (according to IEC 60068-2-27)
Vibration (operation): < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Standards and regulationsStandard - Electrical safety: EN62109-1:2011
Standard – Safety extra-low voltage: IEC 62109-1:2011 (SELV)
Standard - Safe isolation: DINVDE0100-410
Overvoltage category
IEC 62109-1: II
ApprovalsUL approvals: UL62109-1:2014
UL1741
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
Noise immunity: EN 61000-6-2:2005
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
Conducted noise emission: EN55016
EN61000-6-4 (Class A)
Noise emission: EN55016
EN61000-6-4 (Class A)
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: 4 kV (Test Level 2)
Discharge in air: 8 kV (Test Level 3)
Comments: Criterion A
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 1 GHz
1 GHz ... 2.7 GHz
2.7 GHz ... 6 GHz
Test field strength: 10 V/m (> Test intensity 3)
10 V/m (Test Level 2)
3 V/m (Test Level 1)
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: 4 kV (Test Level 4 - asymmetrical)
Output: 4 kV (Test Level 4 - asymmetrical)
Comments: Criterion A
Surge voltage load (surge)
Standards/regulations: EN61000-4-5
Input: 3 kV (Test intensity >4 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Output: 0.5 kV (Test Level 2 - symmetrical)
1 kV (Test Level 2 - asymmetrical)
Comments: Criterion A
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
Input/Output: asymmetrical
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V (Test Level 3)
Voltage dips
Standards/regulations: EN61000-4-11
Emitted interference
Standards/regulations: EN61000-6-4
Radio interference voltage in acc. with EN 55011: EN55011 (EN55022) ClassA industrial area of application
Emitted radio interference in acc. with EN 55011: EN55011 (EN55022) ClassA industrial area of application
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Specifiche
ECLASSECLASS-11.0: 27040701
ECLASS-12.0: 27040701
ECLASS-13.0: 27040701
ETIMETIM 9.0: EC002540
UNSPSCUNSPSC 21.0: 39121000