Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 1151047
PHOENIX CONTACT 1151047
PHOENIX CONTACTNon disponibile

QUINT4-PS/3AC/24DC/40/IOL - Power supply unit

Primary-switched power supply unit QUINT POWER, Screw connection, DIN rail mounting, input:3-phase, output: 24 VDC / 40 A
Cod. Articolo: 1151047
Cod. Fornitore: 1151047
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
Input dataAC operation
Network type: Star network
Nominal input voltage range: 3x 400 VAC ... 500 VAC
2x 400 VAC ... 500 VAC
Input voltage range: 3x 400 VAC ... 500 VAC -20%...+10%
2x 400 VAC ... 500 VAC -10%...+10%
Typical national grid voltage: 400 VAC
480 VAC
Voltage type of supply voltage: AC/DC
Inrush current: typ. 1.5 A (at 25°C)
Inrush current integral (I2t): < 0.06 A2s
Inrush current limitation: 1.5 A (after 1ms)
AC frequency range: 50 Hz ... 60 Hz -10%...+10%
Frequency range (fN): 50 Hz ... 60 Hz -10%...+10%
Mains buffering time: typ. 26 ms (3x 400 V AC)
typ. 26 ms (3x 480 V AC)
Current consumption: 3x 1.8 A (400VAC)
3x 1.5 A (480VAC)
2x 3 A (400VAC)
2x 2.5 A (480VAC)
3x 1.5 A (500 V AC)
2x 2.4 A (500 V AC)
Reverse polarity protection: yes
Nominal power consumption: 1217 VA
Protective circuit: Transient surge protection; Varistor, gas-filled surge arrester
Power factor (cos phi): 0.95
Switch-on time: < 1 s
Typical response time: 300 ms (from SLEEP MODE)
Recommended breaker for input protection: 3x 4 A ... 20 A (Characteristic B, C, D, K or comparable)
Recommended fuse for input protection: ≥ 300 VAC
Discharge current to PE: < 3.5 mA
1 mA (550 V AC, 60 Hz)
DC operation
Nominal input voltage range: ± 260 VDC ... 300 VDC
Input voltage range: ± 260 VDC ... 300 VDC -13%...+30%
Current consumption: 2.2 A (±260VDC)
1.9 A (±300VDC)
Nominal power consumption: 1217 VA
Recommended breaker for input protection: 1x 6 A (10 x 38 mm, 30 kA L/R = 2 ms)
Recommended fuse for input protection: ≥ 1000 VDC
Output dataEfficiency: typ. 95.4 % (400VAC)
typ. 95.4 % (480VAC)
Nominal output voltage: 24 VDC
Setting range of the output voltage (USet): 24 VDC ... 29.5 VDC (constant capacity)
Nominal output current (IN): 40 A
Static Boost (IStat.Boost): 45 A
Dynamic Boost (IDyn.Boost): 60 A (5 s)
Selective Fuse Breaking (ISFB): 215 A (15 ms)
Magnetic circuit breaker tripping: A1...A40 / B2...B25 / C1...C13 / Z1...Z16
Derating: > 60°C ... 70°C (2.5%/K)
Feedback voltage resistance: ≤ 35 VDC
Protection against overvoltage at the output (OVP): ≤ 32 VDC
Control deviation: < 0.5 % (Static load change 10% ... 90%)
< 3 % (Dynamic load change 10% ... 90%, (10 Hz))
< 0.25 % (change in input voltage ±10 %)
Residual ripple: < 50 mVPP (with nominal values)
Short-circuit-proof: yes
No-load proof: yes
Output power: 960 W
1080 W
1440 W
Maximum no-load power dissipation: < 5 W (400VAC)
< 5 W (480VAC)
Power loss nominal load max.: < 45 W (400VAC)
< 45 W (480VAC)
Power dissipation SLEEP MODE: < 2 W (400VAC)
< 2 W (480VAC)
Crest factor: typ. 1.6 (400VAC)
typ. 1.9 (480VAC)
Rise time: < 1 s (UOut=10%...90%)
Connection in parallel: yes, for redundancy and increased capacity
Connection in series: yes
Signal relay 13/14 (configurable)
Default: closed (Uout > 0.9 USet)
Digital: 24 VDC 1 A
30 V AC/DC 0.5 A
Connection dataInput
Connection method: Screw connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 6 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 4 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.: 0.25 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.: 4 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.: 0.25 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.: 4 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 10
Stripping length: 8 mm
Tightening torque, min: 0.5 Nm
Tightening torque max: 0.6 Nm
Output
Connection method: Screw connection
Conductor cross section, rigid min.: 0.5 mm²
Conductor cross section, rigid max.: 16 mm²
Conductor cross section flexible min.: 0.5 mm²
Conductor cross section flexible max.: 16 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.: 0.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.: 16 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.: 0.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.: 16 mm²
Conductor cross section AWG min.: 20
Conductor cross section AWG max.: 6
Stripping length: 10 mm
Tightening torque, min: 1.2 Nm
Tightening torque max: 1.5 Nm
Signal
Connection method: Push-in connection
Conductor cross section, rigid min.: 0.2 mm²
Conductor cross section, rigid max.: 1 mm²
Conductor cross section flexible min.: 0.2 mm²
Conductor cross section flexible max.: 1.5 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, min.: 0.2 mm²
Single conductor/flexible terminal point with ferrule with plastic sleeve, max.: 1.5 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, min.: 0.2 mm²
Single conductor/flexible terminal point with ferrule without plastic sleeve, max.: 1.5 mm²
Conductor cross section AWG min.: 24
Conductor cross section AWG max.: 16
Stripping length: 8 mm
InterfacesIO-Link
Reverse polarity protection: yes
IO-Link​
Specification: V1.1
Interface: IO-Link
Connection method: 3-conductor port classA
Connection marking: 3.3 (L+)
3.4 ()
3.5 (L-)
Transmission speed: 230 kbps (COM3)
Cycle time: 2 ms
Electrical isolation: yes
Amount of process data: 6 Byte (Input data)
Device ID: 262657dec/ 0x040201hex
Vendor ID: 00B0hex / 176dez
System communication
Interface: System communication
Connection method: 2-conductor
Connection marking: 3.6 ()
3.5 (L-/Sgnd)
Electrical isolation: yes
SignalingSignal output
POut: > 100% (LED lights up yellow, output power > 960W)
> 75% (LED lights up green, output power > 720W)
> 50% (LED lights up green, output power > 480W)
UOut: > 0.9xUSet (LED lights up green)
< 0.9xUSet (LED flashes green)
Electrical propertiesNumber of phases: 3.00
Insulation voltage input/output: 4 kV AC (type test)
2.4 kV AC (routine test)
Insulation voltage output / PE: 0.5 kV DC (type test)
0.5 kV DC (routine test)
Insulation voltage input / PE: 3.5 kV AC (type test)
2.4 kV AC (routine test)
Switching frequency: 32 kHz ... 100 kHz (Auxiliary converter stage)
55 kHz ... 300 kHz (Main converter stage)
25 kHz ... 500 kHz (PFC stage)
Product propertiesProduct type: Power supply
Product family: QUINT POWER
MTBF (IEC 61709, SN 29500): > 849000 h (25°C)
> 517000 h (40°C)
> 236000 h (60°C)
Environmental protection directive: RoHS Directive 2011/65/EU
WEEE
Reach
Insulation characteristics
Protection class: I
Degree of pollution: 2
Life expectancy (electrolytic capacitors)
Current: 20 A
Temperature: 40°C
Time: 394000 h
Additional text: 400VAC
Life expectancy (electrolytic capacitors)​
Current: 20 A
Temperature: 40°C
Time: 367000 h
Additional text: 480VAC
Life expectancy (electrolytic capacitors)​​
Current: 40 A
Temperature: 25°C
Time: 394000 h
Additional text: 400VAC
Life expectancy (electrolytic capacitors)​​​
Current: 40 A
Temperature: 25°C
Time: 367000 h
Additional text: 480VAC
Life expectancy (electrolytic capacitors)​​​​
Current: 40 A
Temperature: 40°C
Time: 139000 h
Additional text: 400VAC
Life expectancy (electrolytic capacitors)​​​​​
Current: 40 A
Temperature: 40°C
Time: 130000 h
Additional text: 480VAC
DimensionsWidth: 120 mm
Height: 130 mm
Depth: 125 mm
Installation dimensions
Installation distance right/left: 5 mm / 5 mm
Installation distance top/bottom: 50 mm / 50 mm
MountingMounting type: DIN rail mounting
Mounting position: horizontal DIN rail NS 35, EN 60715
With protective coating: No
Material specificationsFlammability rating according to UL94 (housing / terminal blocks): V0
Housing material: Metal
Hood version: Stainless steel X6Cr17
Side element version: Aluminum
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 70°C (>60°C Derating: 2,5%/K)
Ambient temperature (storage/transport): -40°C ... 85°C
Ambient temperature (start-up type tested): -40°C
Maximum altitude: ≤ 5000 m (> 2000 m, observe derating)
Climatic class: 3K3 (in acc. with EN 60721)
Max. permissible relative humidity (operation): ≤ 95 % (at 25°C, non-condensing)
Shock: 11ms, 15g, in each space direction (according to IEC 60068-2-27)
Vibration (operation): 5Hz ... 100Hz resonance search 0.7g, 90min., resonance frequency 0.7g, 90min. (in accordance with DNV GL Class A)
5Hz ... 100Hz resonance search 2.3g, 90min., resonance frequency 2.3g, 90min. (according to DNV GL Class C) mounted with UWA 130 - 2901664
Standards and regulationsRail applications: EN50121-3-2
EN50121-5
IEC 62236-3-2
IEC 62236-5
HART FSK Physical Layer Test Specification Compliance: Output voltage UOut compliant
Standard – Limitation of mains harmonic currents: EN61000-3-2
Standard – Safety extra-low voltage: IEC 61010-1 (SELV)
IEC 61010-2-201 (PELV)
Standard - Safe isolation: IEC 61558-2-16
IEC 61010-2-201
Standard - safety for equipment for measurement, control, and laboratory use: IEC 61010-1
Standard - Safety of transformers: EN61558-2-16
Battery charging: DIN41773-1
Approval - requirement of the semiconductor industry with regard to mains voltage dips: SEMIF47-0706, EN61000-4-11
Overvoltage category
EN 61010-1: II(≤5000m)
EN 62477-1: III(≤2000m)
EN61558-2-16: II(≤4000m)
ApprovalsCSA: CAN/CSA-C22.2 No.61010-1-12
CAN/CSA-C22.2 No.61010-2-201
SIQ: CB-Scheme (IEC 61010-1, IEC 61010-2-201)
UL approvals: UL Listed UL61010-1
UL Listed UL61010-2-201
UL121201 & CSAC22.2No.213-17 ClassI, Division2, Groups A, B, C, D T4 (Hazardous Location)
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive 2014/35/EC
EMC requirements for noise emission: EN61000-6-3
EN61000-6-4
EMC requirements for noise immunity: EN61000-6-1
EN61000-6-2
Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU
EMC requirements, power plant: EN61000-6-5
Conducted noise emission: EN55016
EN61000-6-3 (Class B)
Noise emission: Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply)
EN55016
EN61000-6-3 (Class B)
Harmonic currents
Standards/regulations: EN61000-3-2
EN61000-3-2 (Class A)
Frequency range: 0 kHz ... 2 kHz
Flicker
Standards/regulations: EN61000-3-3
Frequency range: 0 kHz ... 2 kHz
Electrostatic discharge
Standards/regulations: EN61000-4-2
Electrostatic discharge​
Contact discharge: 8 kV (Test Level 4)
Discharge in air: 15 kV (Test Level 4)
Comments: Criterion B
Electromagnetic HF field
Standards/regulations: EN61000-4-3
Electromagnetic HF field​
Frequency range: 80 MHz ... 1 GHz
1 GHz ... 6 GHz
Test field strength: 20 V/m (Test Level 3)
10 V/m (Test Level 3)
Comments: Criterion A
Fast transients (burst)
Standards/regulations: EN61000-4-4
Fast transients (burst)​
Input: 4 kV (Test Level 4 - asymmetrical)
Output: 2 kV (Test Level 4 - asymmetrical)
Signal: 2 kV (Test Level 4 - asymmetrical)
Comments: Criterion B
Surge voltage load (surge)
Standards/regulations: EN61000-4-5
Input: 2 kV (Test Level 3 - symmetrical)
6 kV (Test Level 4 - asymmetrical)
Output: 1 kV (Test Level 3 - symmetrical)
2 kV (Test Level 3 - asymmetrical)
Signal: 1 kV (Test Level 2 - asymmetrical)
Comments: Criterion B
Conducted interference
Standards/regulations: EN61000-4-6
Conducted interference​
I/O/S: asymmetrical
Frequency range: 0.15 MHz ... 80 MHz
Comments: Criterion A
Voltage: 10 V (Test Level 3)
Power frequency magnetic field
Standards/regulations: EN61000-4-8
Frequency: 16.7 Hz
50 Hz
60 Hz
50 Hz
60 Hz
0 Hz
Test field strength: 100 A/m
1 kA/m
300 A/m
Additional text: 60 s
3 s
DC, 60s
Comments: Criterion A
Frequency range: 50 Hz ... 60 Hz
Voltage dips
Standards/regulations: EN61000-4-11
Voltage: 400 VAC
Frequency: 50 Hz
Voltage dip: 70 %
40 %
0 %
Number of periods: 0.5 / 1 / 25 periods
5 / 10 / 50 periods
0,5 / 1 / 5 / 50 / 250 periods
Additional text: Test Level 2
Comments: Criterion A: 0.5 / 1 period
Criterion B: 25 periods
Criterion B
Criterion A: 0.5 / 1 period
Criterion B: 5 / 50 / 250 periods
Pulse-shape magnetic field
Standards/regulations: EN61000-4-9
Test field strength: 1000 A/m
Comments: Criterion A
Attenuated sinusoidal oscillations (ring wave)
Standards/regulations: EN61000-4-12
Input: 2 kV (Test Level 4 - symmetrical)
4 kV (Test Level 4 - asymmetrical)
Comments: Criterion A
Asymmetrical conducted disturbance variables
Standards/regulations: EN61000-4-16
Test level 1: 15 Hz 150 Hz (Test Level 3)
Voltage: 10 V 1 V
1 V
1 V 10 V
10 V
10 V (Permanent)
100 V (1 s)
Test level 2: 150 Hz 1.5 kHz (Test Level 3)
Test level 3: 1.5 kHz 15 kHz (Test Level 3)
Test level 4: 15 kHz 150 kHz (Test Level 3)
Test level 5: 50 Hz 60 Hz (Test Level 3)
Test level 6: 50 Hz 60 Hz (Test Level 3)
Comments: Criterion A
Attenuated oscillating magnetic field
Standards/regulations: EN61000-4-10
Test field strength: 100 A/m
Test level 1: 100 kHz
Test level 2: 1 MHz
Comments: Criterion A
Criteria
Criterion A: Normal operating behavior within the specified limits.
Criterion B: Temporary impairment to operational behavior that is corrected by the device itself.
Criterion C: Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
Specifiche
ECLASSECLASS-11.0: 27040701
ECLASS-12.0: 27040701
ECLASS-13.0: 27040701
ETIMETIM 9.0: EC002540
UNSPSCUNSPSC 21.0: 39121000
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01297.pdf

Approvals_01335.pdf

Approvals_01389.pdf

Approvals_01782.pdf

Approvals_01791.pdf

Data_sheet_00854.pdf

Manufacturer_declaration_02869.pdf

Manufacturer_declaration_03232.pdf

Manufacturer_declaration_06597.pdf

Package_slip_02150.pdf

Technical_drawing_09427.pdf

Various_00006.pdf