PHOENIX CONTACT 1159811
PHOENIX CONTACTDisponibile

AXC F XT SPLC 1000 - PLC extension module

The AXCFXTSPLC1000 is a left-alignable, safety-oriented controller for operating PROFIsafe devices. The SPLC1000 is connected to the AXCF2152 or AXCF3152 modular controllers from the PLCnext Control series.
Cod. Articolo: 1159811
Cod. Fornitore: 1159811
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
DimensionsWidth: 45 mm
Height: 126.93 mm
Depth: 75 mm
Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
External dimensions
Width / Height / Depth: 45 mm / 126.93 mm / 75 mm (The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).)
NotesGeneral: If the SPLC-1000 is operated with AXCF2152, the AXC BSL 2 bus base module must be used.
InterfacesWeb server: No
System propertiesProcessor: Arm® Cortex®-M4, 180 MHz (CPU1)
Arm® Cortex®-M4, 100 MHz (CPU2)
Function
Diagnostics display: No
Controller redundancy: No
Safety function: yes
System requirements
Engineering tool: PLCnext Engineer
Product propertiesType: modular
Product type: I/O component
Product family: PLCnext Control Extension
Insulation characteristics
Protection class: III (IEC 61140, EN61140, VDE0140-1)
Display
Diagnostics display: No
Electrical propertiesSupply
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Max. current consumption: 100 mA
Typical current consumption: 80 mA
Potentials: Supply of the logic voltage U
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 100 mA
typ. 80 mA
Protective circuit: Reverse polarity protection; Polarity protection diode
Transient protection; Suppressor diode
Connection dataConnection technology
Connection name: AxiolineF connector
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
AxiolineF connector
Connection method: Push-in connection
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 60°C up to 2000m above mean sea level
-25°C ... 55°C up to 3000m above mean sea level
-25°C ... 50°C up to 4000m above mean sea level
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (according to DINEN61131-2)
Permissible humidity (storage/transport): 5 % ... 95 % (according to DINEN61131-2)
Shock (operation): 30g (in accordance with EN60068-2-27/IEC 60068-2-27)
Shock (storage/transport): 30g (in accordance with EN60068-2-27/IEC 60068-2-27)
Vibration (operation): 5g (in accordance with EN60068-2-6/IEC 60068-2-6)
Vibration (storage/transport): 5g (in accordance with EN60068-2-6/IEC 60068-2-6)
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 58 kPa ... 106 kPa (up to 4500m above mean sea level)
Resistance to gases that may endanger the functions, in acc. with DIN 40046-36, DIN 40046-37: Use of the device in these ambient conditions is prohibited.
ApprovalsATEX
Identification:  II 3 G Ex ec IIC T4 Gc
Certificate: UL21ATEX2651X
IECEx
Identification: Ex ec IIC T4 Gc
Certificate: IECExULD21.0029X
UL Ex, USA / Canada
Identification: Class I, Zone 2, AEx ec IIC T4, Ex ec IIC T4 Gc X
Class I, Div. 2 Groups A, B, C, D T4
Certificate: E366272
UL, USA/Canada
Identification: cULus
Certificate: E238705
Industrial Cyber Security
Identification: IndustrialITSecurity, IACSComponent
Certificate: IITS20294290027
Note: Configuration: SecurityProfileactive
MountingMounting type: DIN rail mounting
Connection method: Push-in connection
Specifiche
ECLASSECLASS-11.0: 27242207
ECLASS-12.0: 27242207
ECLASS-13.0: 27242207
ETIMETIM 9.0: EC000236
UNSPSCUNSPSC 21.0: 32151700
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00038.pdf

Application_note_00183.pdf

Application_note_00037.pdf

Approvals_00865.pdf

Approvals_01199.pdf

Approvals_01523.pdf

Approvals_01803.pdf

Approvals_01817.pdf

Certification_00100.pdf

Manual_00078.pdf

Manual_00007.pdf

Manufacturer_declaration_01467.pdf

Manufacturer_declaration_04142.pdf

Package_slip_00635.pdf

Product_information_00033.pdf

Product_information_00096.pdf

Technical_drawing_09673.pdf