Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 1344363
PHOENIX CONTACTNon disponibile

CAPAROC PM S-R EX - Power module

Power module with status output and reset input for supplying the CAPAROC circuit breaker system with 12VDC or 24VDC. EXe approval for zone2. For DIN rail installation via the CAPAROC current rails.
Cod. Articolo: 1344363
Cod. Fornitore: 1344363
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
NotesGeneral
Note: LABS release – in accordance with test specification VWPV3.10.7:2005-0
When connecting the conductor, make sure that the CAPAROC modules are not pulled apart due to tensile force. Gaps must not be created between the modules.
Observe the specified conditions for use in potentially explosive areas. Install the device in a suitable approved housing with at least IP54 degree of protection that meets the requirements of IEC/EN60079-0. Also observe the requirements of IEC/EN60079-14.
Product propertiesType: Plug-in module
Product type: Device circuit breakers
Product family: CAPAROC
Number of slots: 2
Insulation characteristics
Protection class: III
Pollution degree: 2
Electrical propertiesGeneral
Operating voltage: 10 VDC ... 30 VDC
Rated voltage: 12 VDC
24 VDC
Rated current IN: 45 ADC (Total current input)
Rated surge voltage: 0.5 kV
Tripping method: E (electronic)
Dielectric strength: 35 VDC (Load circuit)
Efficiency: > 99 %
Closed circuit current I0: typ. 9 mA (no load at 24V)
Power dissipation: typ. 0.22 W (no load at 24V)
< 1.5 W (in nominal operation at 24V and 45A)
Temperature derating: 45 A (Total current at40°C)
30 A (Total current at 65°C)
MTBF (IEC 61709, SN 29500): 18886912.65 h (at 25°C with 21% load)
5907048.64 h (at40°C with 34.25%load)
933563.97 h (at40°C with 100%load)
Voltage drop: 0.03 V (at 45A)
Reset
Input voltage range: 7 VDC ... 30 VDC (Reset with falling edge)
Current consumption: typ. 0.5 mA (at 24 V DC)
Pulse length: ≥ 50 ms
Stripping length: 8 mm
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.2 mm² ... 0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.2 mm² ... 1.5 mm²
Status output
Output voltage: max. 30 VDC (Input voltage±5% in the event of no error)
0 VDC (Error)
Output current: max. 20 mA
Stripping length: 8 mm
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.2 mm² ... 0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.2 mm² ... 1.5 mm²
Status output​
Output voltage: max. 30 VDC (Input voltage±5% when I>80%at at least one channel)
Output current: max. 20 mA
Stripping length: 8 mm
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.2 mm² ... 0.75 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.2 mm² ... 1.5 mm²
Connection dataMain circuit IN+
Connection method: Push-in connection
Stripping length: 18 mm
Conductor cross section rigid: 0.5 mm² ... 16 mm²
Conductor cross section AWG: 20 ... 8
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.5 mm² ... 16 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.5 mm² ... 16 mm²
Main circuit IN-
Connection method: Push-in connection
Stripping length: 18 mm
Conductor cross section rigid: 0.5 mm² ... 16 mm²
Conductor cross section AWG: 20 ... 8
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.5 mm² ... 16 mm²
Conductor cross section flexible, with ferrule without plastic sleeve: 0.5 mm² ... 16 mm²
SignalingPower (PWR) LED green: lit (with no channel errors)
lit (Supply voltage in the nominal range)
flashing (3x on deactivation of programming lock)
Power (PWR) LED red: lit (Supply voltage outside the nominal range)
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3ced5a3a44f3524a884d85a64ccfc6c8/-S204x204-FJPG
Width: 12.4 mm
Height: 132.4 mm
Depth: 111.3 mm (incl. DIN rail 7.5mm)
Material specificationsMaterial: PA 6
PC
Flammability rating according to UL 94: V-0
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -30°C ... 65°C
Ambient temperature (storage/transport): -40°C ... 70°C
Altitude: ≤ 4000 m (amsl)
Humidity test: 96h, 95%RH, 40°C
Shock (operation): 30g (11 ms period, half-sine shock pulse, according to IEC 60068-2-27)
25g (6ms duration, half-sine shock pulse in accordance with IEC 60068-2-27, continuous shock)
Vibration (operation): 5g (10 ... 150Hz / 10cycles / axis / X,Y,Z)
ApprovalsUL approval
Identification: UL/C-UL Listed UL 508
UL 121201 Class I, Division 2, Groups A, B, C, D, T4A
ATEX
Identification: TÜV22 ATEX8874 X
II 3G Ex ec IIC T4 Gc
IECEx
Identification: IECExTUR22.0049X
II 3G Ex ec IIC T4 Gc
UKCAEx(UKEX)
Identification: TÜV22UKEX7109X
II 3G Ex ec IIC T4 Gc
Standards and regulationsStandards/specifications: EN61000-6-2
EN61000-6-3
EN60068-2-78
EN50178
EN60068-2-27
IEC 60079-7
IEC 60079-0
Note: EMC – Immunity for industrial areas
EMC – Emission for residential, business and commercial properties and small operations
Environmental influences – Moisture and heat, constant
Equipping power installations with electronic equipment
Environmental influences – Shocks
Explosive atmospheres – Part7: Equipment protection by increased safety “e”
Explosive atmospheres – Part0: Equipment – General requirements
MountingMounting type: pluggable onto CAPAROC CR… current rail
Specifiche
ECLASSECLASS-11.0: 27140401
ECLASS-12.0: 27140401
ECLASS-13.0: 27140401
ETIMETIM 9.0: EC003538
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00054.pdf

Approvals_00055.pdf

Approvals_00466.pdf

Approvals_00467.pdf

Approvals_00989.pdf

Approvals_00990.pdf

Approvals_00991.pdf

Flyer_00005.pdf

Flyer_00004.pdf

Manufacturer_declaration_04241.pdf

Manufacturer_declaration_04242.pdf

Package_slip_00225.pdf

Product_information_00033.pdf

Product_information_00122.pdf

Technical_drawing_11615.pdf

Various_00001.pdf