NBC-MS/ 2,0-94B/R4RC SCO - Network cable

Network cable, Ethernet CAT5 (1 Gbps), 8-position, shielded, Plug straight M12, coding: A SPEEDCON / IP67, on Plug straight RJ45 Push Pull / IP67, cable length: 2 m
Cod. Articolo: 1407427
Cod. Fornitore: 1407427
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
NotesGeneral: Further products with variable cable type and variable cable length can be found in the accessories section
Product propertiesProduct type: Data cable preassembled
Sensor type: Ethernet
Number of positions: 8
Application: Standard
Shielded: yes
Coding: A
InterfacesBus system: Ethernet
Signal type/category: Ethernet CAT5 (based on IEC 11801), 1 Gbps
SignalingStatus display: No
Status display present: No
Electrical propertiesNominal voltage UN: 30 VAC
30 VDC
Nominal current IN: 1 A
Transmission medium: Copper
Transmission characteristics (category): CAT5 (IEC 11801:2002)
ConnectorConnection 1
Type: Plug straight M12 SPEEDCON / IP67
Number of positions: 8
Coding type: A (Standard)
Handle color: black
Material: CuZn (Contact)
Ni/Au (Contact surface)
TPU GF (Contact carriers)
TPU, hardly inflammable, self-extinguishing (Grip)
Zinc die-cast, nickel-plated (Screw connection)
Insertion/withdrawal cycles: ≥ 100
100
Contact resistance: ≤ 5 mΩ
Insulation resistance: ≥ 100 MΩ
Tightening torque: 0.4 Nm
Degree of protection: IP67
Ambient temperature (operation): -25°C ... 90°C
Locking type: SPEEDCON
Connection 2
Type: Plug straight RJ45 Push Pull / IP67
Number of positions: 8 (8)
8
Handle color: silver
Material: CuSn (Contact)
Ni/Au (Contact surface)
PC (Contact carriers)
Zinc die-cast, nickel-plated (Housing)
Insertion/withdrawal cycles: ≥ 750
Ambient temperature (operation): -40°C ... 70°C
Degree of protection: IP67
Locking type: Push Pull
Cable/lineCable length: 2 m
Ethernet flexible CAT5, 4-pair[94B]
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/4c3fd6859f812544824572f75cfdd10c/-S204x204-FJPG
Cable weight: 47 kg/km
UL AWM Style: 20963 (80°C/30 V)
Number of positions: 8
Shielded: yes
Cable type: Ethernet flexible CAT5, 4-pair[94B]
Conductor structure: 4x2xAWG26/7, SF/UTP
Signal runtime: 5.3 ns/m
Conductor structure signal line: 7x 0.16 mm
AWG signal line: 26
Conductor cross section: 4x 2x 0.14 mm²
Wire diameter incl. insulation: 0.96 mm
External cable diameter: 6.4 mm ±0.2mm
Outer sheath, material: PUR
External sheath, color: water blue RAL5021
Conductor material: Bare Cu litz wires
Material wire insulation: Foamed PE
Single wire, color: white/blue-blue, white/orange-orange, white/green-green, white/brown-brown
Thickness, outer sheath: 1.05 mm
Twisted pairs: 2 cores to the pair
Overall twist: 4 pairs for core
Optical shield covering: 70 %
Insulation resistance: ≥ 5 GΩ*km
Coupling resistance: ≤ 100.00 mΩ/m (at 10 MHz)
Loop resistance: ≤ 290.00 Ω/km
Wave impedance: 100 Ω ±5Ω (at 100 MHz)
Cable capacity: 48 nF/km (at 1 kHz)
Nominal voltage, cable: ≤ 100 V
Test voltage Core/Core: 700 V (50Hz, 1min.)
Test voltage Core/Shield: 700 V (50Hz, 1min.)
Minimum bending radius, fixed installation: 4 x D
Minimum bending radius, flexible installation: 8 x D
Smallest bending radius, fixed installation: 26 mm
Smallest bending radius, movable installation: 52 mm
Tensile strength: ≤ 100 N
Near end crosstalk attenuation (NEXT): 71.3 dB (with 1 MHz)
62.3 dB (at 4 МHz)
56.3 dB (at 10 MHz)
53.2 dB (at 16 MHz)
51.8 dB (at 20МHz)
48.9 dB (at 31.25МHz)
44.4 dB (at 62.5МHz)
41.3 dB (at 100 MHz)
Power-summated near end crosstalk attenuation (PSNEXT): 62.3 dB (with 1 MHz)
53.3 dB (at 4 МHz)
47.3 dB (at 10 MHz)
44.2 dB (at 16 MHz)
42.8 dB (at 20МHz)
39.9 dB (at 31.25МHz)
35.4 dB (at 62.5МHz)
32.3 dB (at 100 MHz)
Return attenuation (RL): 23 dB (at 4 МHz)
24.1 dB (at 8МHz)
25 dB (at 10 MHz)
25 dB (at 16 MHz)
25 dB (at 20МHz)
23.6 dB (at 31.25МHz)
21.5 dB (at 62.5МHz)
20.1 dB (at 100 MHz)
Shield attenuation: 3.2 dB (with 1 MHz)
6 dB (at 4 МHz)
9.5 dB (at 10 MHz)
12.1 dB (at 16 MHz)
13.6 dB (at 20МHz)
17.1 dB (at 31.25МHz)
24.8 dB (at 62.5МHz)
32 dB (at 100 MHz)
Halogen-free: according to IEC 60754-1
Flame resistance: according to IEC 60332-1-2
Resistance to oil: in accordance with EN 60811-2-1
Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation)
-20°C ... 80°C (Cable, flexible installation)
Ambient temperature (installation): -20°C ... 80°C
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP65 (M12 connector)
IP67 (M12 connector)
IP67 (RJ45 connector)
Ambient temperature (operation): -25°C ... 90°C (M12 connector)
-40°C ... 70°C (RJ45 connector)
Standards and regulationsM12
Standard designation: M12 connector
Standards/specifications: IEC 61076-2-101
Specifiche
ECLASSECLASS-11.0: 27060307
ECLASS-12.0: 27060307
ECLASS-13.0: 27060307
ETIMETIM 9.0: EC001855
UNSPSCUNSPSC 21.0: 26121600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Manufacturer_declaration_00216.pdf

Manufacturer_declaration_02419.pdf

Manufacturer_declaration_05519.pdf