Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 1423514
PHOENIX CONTACTNon disponibile

NBC-100,0-94S - Data cable

Data cable, Ethernet CAT7 (10 Gbps), 8-position, cable length: 100 m
Cod. Articolo: 1423514
Cod. Fornitore: 1423514
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
Product propertiesProduct type: Data cable by the meter
Sensor type: Ethernet
Number of positions: 8
Application: Railway applications
Electrical propertiesNominal voltage UN: 30 VAC
30 VDC
Transmission medium: Copper
InterfacesSignal type/category: Ethernet CAT7, 10 Gbps
Cable/lineCable length: 100 m
Ethernet BETAtrans
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/1f08ac23481cba498cd37c88ad48a160/-S204x204-FJPG
Cable weight: 59 kg/km
Copper weight: 28 kg/km
Number of positions: 8
Shielded: yes
Cable type: Ethernet BETAtrans® railway application CAT7[94S]
Conductor structure: 4x2xAWG26/7; S/FTP
Signal runtime: 4.4 ns/m
Signal speed: 0.78 c
Conductor structure signal line: 7x 0.16 mm
AWG signal line: 26
Conductor cross section: 4x 2x 0.14 mm²
Wire diameter incl. insulation: 1.05 mm ±0.1mm
External cable diameter: 6.6 mm ±0.2mm
Outer sheath, material: PE-X
External sheath, color: black
Conductor material: Tin-plated Cu litz wires
Material wire insulation: Cell PE
Single wire, color: white-blue, white-orange, white-green, white-brown
Twisted pairs: 2 cores to the pair
Type of pair shielding: Aluminum-lined polyester foil
Overall twist: 4 pairs, twisted
Max. conductor resistance: ≤ 145 Ω/km
Insulation resistance: ≥ 5 GΩ*km
Coupling resistance: 5.00 mΩ/m (at 10 MHz)
Wave impedance: 100 Ω ±5Ω (at 100 MHz)
Working capacitance: 44 nF (per kilometer)
Nominal voltage, cable: 125 VAC (Uo)
Test voltage Core/Core: 1000 VAC (50Hz, 1min.)
Test voltage Core/Shield: 1000 VAC (50Hz, 1min.)
Minimum bending radius, fixed installation: 6 x D
Tensile strength: ≤ 60 N (temporary)
≤ 15 N (Permanent)
Near end crosstalk attenuation (NEXT): 100 dB (with 1 MHz)
99 dB (at 10 MHz)
95 dB (at 100 MHz)
92 dB (at 200 MHz)
90 dB (at 250MHz)
83 dB (at 500MHz)
81 dB (at 600MHz)
80 dB (at 700MHz)
77 dB (at 800MHz)
75 dB (at 900MHz)
74 dB (at 1000 MHz)
72 dB (at 1100MHz)
70 dB (at 1200MHz)
Power-summated near end crosstalk attenuation (PSNEXT): 97 dB (with 1 MHz)
96 dB (at 10 MHz)
92 dB (at 100 MHz)
89 dB (at 200 MHz)
87 dB (at 250MHz)
80 dB (at 500MHz)
78 dB (at 600MHz)
77 dB (at 700MHz)
74 dB (at 800MHz)
72 dB (at 900MHz)
71 dB (at 1000 MHz)
69 dB (at 1100MHz)
67 dB (at 1200MHz)
Return attenuation (RL): 24 dB (with 1 MHz)
33.9 dB (at 10 MHz)
38.3 dB (at 100 MHz)
35.3 dB (at 200 MHz)
32.9 dB (at 250MHz)
29.7 dB (at 500MHz)
30.6 dB (at 600MHz)
31 dB (at 700MHz)
26.7 dB (at 800MHz)
28.6 dB (at 900MHz)
27.5 dB (at 1000 MHz)
26.9 dB (at 1100MHz)
26.3 dB (at 1200MHz)
Crosstalk attenuation (ACR): 100 dB (with 1 MHz)
99 dB (at 10 MHz)
93 dB (at 100 MHz)
88 dB (at 200 MHz)
86 dB (at 250MHz)
78 dB (at 500MHz)
74 dB (at 600MHz)
72 dB (at 700MHz)
69 dB (at 800MHz)
67 dB (at 900MHz)
65 dB (at 1000 MHz)
63 dB (at 1100MHz)
61 dB (at 1200MHz)
Power-summated crosstalk attenuation (PS-ACR): 97 dB (with 1 MHz)
96 dB (at 10 MHz)
90 dB (at 100 MHz)
85 dB (at 200 MHz)
83 dB (at 250MHz)
75 dB (at 500MHz)
71 dB (at 600MHz)
69 dB (at 700MHz)
66 dB (at 800MHz)
64 dB (at 900MHz)
62 dB (at 1000 MHz)
60 dB (at 1100MHz)
58 dB (at 1200MHz)
Shield attenuation: 0.25 dB (with 1 MHz)
0.76 dB (at 10 MHz)
2.49 dB (at 100 MHz)
3.69 dB (at 200 MHz)
4.18 dB (at 250MHz)
5.6 dB (at 500MHz)
6.74 dB (at 600MHz)
7.32 dB (at 700MHz)
7.89 dB (at 800MHz)
8.5 dB (at 900MHz)
9.11 dB (at 1000 MHz)
9.5 dB (at 1100MHz)
9.9 dB (at 1200MHz)
60 dB (up to 1000 MHz)
Halogen-free: in accordance with EN 50267-2-1
in accordance with EN 60684-2
Flame resistance: in accordance with EN60332-1-2
EN60332-3-25
in accordance with ISO 14572 5.21 (UN ECE-R 118.01)
Concentration of fumes: EN 61034-2
Resistance to oil: in accordance with EN 50306-4, 72 hours at 100°C, IRM 902
Fire protection in rail vehicles: BS6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II)
DIN5510-2 (Fire protection level 1, 2, 3, 4)
EN45545-2
EN50306-4
NFF16-101 (Classification C/F1)
NFF16-101 (Internal cable A1, A2, B/external cable A1, A2, B)
NFPA130
PN-K-02511 (ClassA)
UIC564-2 (ClassA)
Other resistance: Resistant to fuel in accordance with EN50306-4, 168 hours at 70°C, IRM 903
Resistant to ozone in accordance with EN50306-4, 72 hours at 40°C, method B, volumetric concentration of 200 x 10-6
Special properties: HL1-HL3
Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation)
Specifiche
ECLASSECLASS-11.0: 27061801
ECLASS-13.0: 27061801
ETIMETIM 9.0: EC003249
UNSPSCUNSPSC 21.0: 26121600
Descrizione
By the meter, Network cable, Ethernet CAT7 (10 Gbps), shielded, PE-X halogen-free, black, 8-wire (4x2xAWG26/7; S/FTP), color single wire: White-blue, white-orange, white-green, white-brown, cable length: 100 m, For railway applications
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Manufacturer_declaration_00216.pdf

Manufacturer_declaration_02419.pdf

Manufacturer_declaration_05519.pdf