PHOENIX CONTACT 1525911
PHOENIX CONTACTNon disponibile

SACCEC-M12FSB-2CON-M16/10-910 - Device connector front mounting

Device connector front mounting, 2-position halogen-free, red lilac RAL 4001, shielded, Socket, straight, M12, coding: B, on free cable end, Front mounting, M16 x 1.5, cable length: 10 m, PROFIBUS, Alternative product in accordance with RoHS II without Exemption6c (Pb<0.1%) item no.: 1239898
Cod. Articolo: 1525911
Cod. Fornitore: 1525911
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
NotesGeneral: The electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Lock nut is included in the scope of delivery
Safety note
Safety note: WARNING: The connectors may not be plugged in or disconnected under load. Ignoring the warning or improper use may damage persons and/or property.
• WARNING: Commission properly functioning products only. The products must be regularly inspected for damage. Decommission defective products immediately. Replace damaged products. Repairs are not possible.
• WARNING: Only electrically qualified personnel may install and operate the product. They must observe the following safety notes. The qualified personnel must be familiar with the basics of electrical engineering. They must be able to recognize and prevent danger. The relevant symbol on the packaging indicates that only personnel familiar with electrical engineering are allowed to install and operate the product.
• The products are suitable for applications in plant, controller, and electrical device engineering.
• When operating the connectors in outdoor applications, they must be separately protected against environmental influences.
• Assembled products may not be manipulated or improperly opened.
• Only use mating connectors that are specified in the technical data of the standards listed (e.g. the ones listed in the product accessories online at phoenixcontact.com/products).
• When using the product in direct connection with third-party manufacturers, the user is responsible.
• For operating voltages > 50V AC, conductive connector housings must be grounded
• Ensure that when laying the cable, the tensile load on the connectors does not exceed the upper limit specified in the standards.
• Observe the corresponding technical data. You will find information:
o On the product
o On the packing label
o In the supplied documentation
o Online at phoenixcontact.com/products under the product
• Only use tools recommended by PhoenixContact
• Use a protective cap to protect connectors that are not in use. The suitable accessories are available online in the accessory section of the product at phoenixcontact.com/products
• Ensure that the protective or functional ground has been properly connected.
• VDE 0100/1.97 § 411.1.3.2 and DIN EN 60 204/11.98 § 14.1.3 are applicable when combining several circuits in a cable and/or connector
• The connector warms up in normal operation. Depending on the ambient conditions, the surface of the connector can continue to warm up. In this case, the user is responsible for posting warnings (e.g. DIN EN ISO 13732-1:2008-12).
MountingMounting type: Front mounting M16 x 1.5
Product propertiesProduct type: Circular connectors (device side)
Number of positions: 2
Shielded: yes
Coding: B
Thread type: M12
Insulation characteristics
Overvoltage category: II
Degree of pollution: 3
Material specificationsFlammability rating according to UL 94: V0
Insulating material: PA66
Contact material: CuZn
Contact surface material: Ni/Au
Material for screw connection: Metal
Electrical propertiesRated surge voltage: 1.5 kV
Contact resistance: ≤ 3 mΩ
Insulation resistance: ≥ 100 MΩ
Nominal voltage UN: 48 VAC
60 VDC
Nominal current IN: 4 A (Plug/socket in accordance with IEC 61076-2-101, cable technical data is to be observed)
Test voltage: 2500 V
Transmission medium: Copper
ConnectorConnection 1
Head design: Socket
Head cable outlet: straight
Head thread type: M12
Coding: B
Connection 2
Head design: free cable end
Cable/lineCable length: 10 m
PROFIBUS[910]
Dimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/f1dae8d6dde46a43ab41312f30ec04e8/-S204x204-FJPG
Cable weight: 90 kg/km
UL AWM Style: 21198 (80°C/300 V)
Number of positions: 2
Shielded: yes
Cable type: PROFIBUS[910]
Conductor structure: 1x2xAWG24/19
Conductor structure signal line: 19x 0.13 mm
AWG signal line: 24
Conductor cross section: 2x 0.25 mm² (Signal line)
Wire diameter incl. insulation: 2.55 mm ±0.07mm
External cable diameter: 7.8 mm ±0.2mm
Outer sheath, material: PUR
External sheath, color: red lilac RAL 4001
Conductor material: Tin-plated Cu litz wires
Material, filler: PP
Material wire insulation: Foam-Skin PP
Single wire, color: red, green
Overall twist: 2 cores with 2 fillers to the core
Optical shield covering: 85 %
Max. conductor resistance: ≤ 78.6 Ω/km
Insulation resistance: ≥ 5 GΩ*km
Wave impedance: 150 Ω ±10% (3 MHz ... 20 MHz)
Cable capacity: nom. 30 pF/m
Nominal voltage, cable: 300 V
Test voltage Core/Core: 1500 V (50Hz, 1min.)
Test voltage Core/Shield: 1500 V (50Hz, 1min.)
Smallest bending radius, fixed installation: 40 mm
Smallest bending radius, movable installation: 65 mm
Max. bending cycles: 4000000
5000000
Shield attenuation: ≤ 0.049 dB/m (at 16 MHz)
Halogen-free: in accordance with DINVDE0472 part815
according to IEC 60754-1
Flame resistance: UL1581, Section 1060 and UL2556, Section 9.3 (FT1)
UL1581, Section 1100 and UL2556, Section 9.1 (HFT/FT2)
IEC 60332-1-2
Other resistance: Low adhesion
Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation)
-30°C ... 70°C (Cable, flexible installation)
-20°C ... 60°C (for installation)
-20°C ... 60°C (cable, drag chain applications)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP67
IP65/IP67
Ambient temperature (operation): -25°C ... 85°C (Plug / socket)
-40°C ... 85°C (without mechanical actuation)
Standards and regulationsM12
Standard designation: M12 connector
Standards/specifications: IEC 61076-2-101
Specifiche
ECLASSECLASS-11.0: 27440103
ECLASS-12.0: 27440103
ECLASS-13.0: 27440103
ETIMETIM 9.0: EC003570
UNSPSCUNSPSC 21.0: 39121400
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00962.pdf

Design-In_00003.pdf

Manufacturer_declaration_05485.pdf

Manufacturer_declaration_09160.pdf

Technical_drawing_16101.pdf