Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 2688051
PHOENIX CONTACTNon disponibile

AXL F DO32/1 1F - Digital module

AxiolineF, Digital output module, Digital outputs:32, 24 VDC, 500 mA, connection technology:1-conductor, transmission speed in the local bus:100 Mbps, degree of protection: IP20, including bus base module and AxiolineF connectors
Cod. Articolo: 2688051
Cod. Fornitore: 2688051
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3f783436b27c3846a361ee861b282789/-S204x204-FJPG
Width: 53.6 mm
Height: 126.1 mm
Depth: 54 mm
Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
InterfacesAxiolineFlocal bus
Number of interfaces: 2
Connection method: Bus base module
Transmission speed: 100 Mbps
System propertiesModule
Input address area: 0 Byte
Output address area: 4 Byte
Required parameter data: 1 Byte
Required configuration data: 6 Byte
Output dataDigital
Output name: Digital outputs
Connection method: Push-in connection
Connection technology: 1-conductor
Number of outputs: 32
Protective circuit: Short-circuit protection, overload protection of the outputs; electronic
Output voltage: 24 VDC
Limitation of the voltage induced on circuit interruption: -32.8 V ... -15 V
Maximum output current per module: 8 A (up to HW04, provide external protection)
16 A (from HW05, provide external protection)
Nominal output voltage: 24 VDC
Load min.: 10 kΩ
Output voltage when switched off: max. 1 V
Output current when switched off: max. 300 µA
Nominal load, inductive: max. 12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, lamp: max. 12 W (at nominal voltage)
Nominal load, ohmic: max. 12 W (48 Ω, with nominal voltage)
Switching frequency: max. 5500 per second (with ohmic load)
max. 1 per second (with inductive load)
max. 16 per second (with nominal lamp load)
Reverse voltage resistance to short pulses: limited protection up to 0.5 A for 1 s
Behavior with overload: Shutdown with automatic restart
Behavior with inductive overload: Output can be destroyed
Signal delay: max. 150 µs (when switched on)
max. 200 µs (during switching off with ohmic nominal load)
Overcurrent shut-down: as of 0.7 A
Output current with ground connection interrupt when switched off: < 1 mA
Product propertiesType: block modular
Product type: I/O component
Product family: AxiolineF
Mounting position: any (no temperature derating)
Scope of delivery: including bus base module and AxiolineF connectors
Insulation characteristics
Overvoltage category: II (IEC 60664-1, EN60664-1)
Pollution degree: 2 (IEC 60664-1, EN60664-1)
Electrical propertiesMaximum power dissipation for nominal condition: 2.7 W
Potentials: AxiolineF local bus supply (U
Supply voltage: 5 VDC (via bus base module)
Current draw: max. 120 mA (up to HW 04)
max. 60 mA (from HW 05)
Power consumption: max. 600 mW (up to HW 04)
max. 300 mW (from HW 05)
Potentials: Supply for digital output modules (U
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 8 A (up to HW04, provide external protection)
max. 16 A (from HW05, provide external protection; if the total current of 8A is exceeded, connect the supply at the power connector parallel via both terminal points.)
Power consumption: max. 240 W (up to HW04, of which 1.5W constitute internal losses)
max. 480 W (from HW05, of which max. 2.4W constitute internal losses)
Protective circuit: Surge protection; electronic (35 V, 0.5 s)
Reverse polarity protection; parallel diode; with external 5A fuse (only for commissioning)
Electrical isolation/isolation of the voltage ranges
Test voltage: 5V supply of the local bus (UBus) / 24V supply (I/Os): 500 VAC, 50 Hz, 1 min.
Test voltage: 5V supply of the local bus (UBus) / functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: AxiolineF connector
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
AxiolineF connector
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: DIN rail mounting
Mounting position: any (no temperature derating)
Specifiche
ECLASSECLASS-11.0: 27242604
ECLASS-12.0: 27242604
ECLASS-13.0: 27242604
ETIMETIM 9.0: EC001599
UNSPSCUNSPSC 21.0: 32151600
Descrizione
Axioline F, Digital output module, Digital outputs: 32, 24 V DC, 500 mA, connection method: 1-wire, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00785.pdf

Approvals_01195.pdf

Approvals_01203.pdf

Approvals_01303.pdf

Approvals_01758.pdf

Approvals_01816.pdf

Approvals_01836.pdf

Approvals_01893.pdf

Approvals_01935.pdf

Data_sheet_03152.pdf

Manual_00006.pdf

Manual_00007.pdf

Manufacturer_declaration_00696.pdf

Manufacturer_declaration_01606.pdf

Manufacturer_declaration_05480.pdf

Manufacturer_declaration_05562.pdf

Manufacturer_declaration_05563.pdf

Manufacturer_declaration_14399.pdf

Package_slip_00641.pdf

Package_slip_00736.pdf

Product_information_00033.pdf

Product_information_00234.pdf

Technical_drawing_37498.pdf

Various_00004.pdf