AXL F AO8 1F - Analog module

AxiolineF, Analog output module, Analog outputs: 8, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection technology: 2-conductor, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and AxiolineF connectors
Cod. Articolo: 2688080
Cod. Fornitore: 2688080
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3f783436b27c3846a361ee861b282789/-S204x204-FJPG
Width: 53.6 mm
Height: 126.1 mm
Depth: 54 mm
Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
InterfacesAxiolineFlocal bus
Number of interfaces: 2
Connection method: Bus base module
Transmission speed: 100 Mbps
System propertiesModule
Input address area: 16 Byte
Output address area: 16 Byte
Required parameter data: 27 Byte
Required configuration data: 7 Byte
Output dataAnalog
Output name: Analog outputs
Connection method: Push-in connection
Connection technology: 2-conductor
Note regarding the connection technology: shielded, twisted pair
Number of outputs: 8
D/A conversion time: 5 µs
D/A converter resolution: 16 bit
Protective circuit: Short-circuit and overload protection; electronic
Transient protection; Suppressor diode
Data formats: IB IL, S7-compatible
Representation of output values: 16 bits (15 bits + sign)
Process data update: 300 µs
Current output signal: 0 mA ... 20 mA
4 mA ... 20 mA
-20 mA ... 20 mA
Load/output load current output: to 500 Ω
Voltage output signal: 0 V ... 5 V
-5 V ... 5 V
0 V ... 10 V
-10 V ... 10 V
Load/output load voltage output: > 2 kΩ
Permissible cable length: max. 250 m (Reference cable type LiYCY (TP) n*2*0.5mm²)
Product propertiesType: block modular
Product type: I/O component
Product family: AxiolineF
Mounting position: any (observe temperature derating)
Scope of delivery: including bus base module and AxiolineF connectors
Insulation characteristics
Overvoltage category: II (IEC 60664-1, EN60664-1)
Pollution degree: 2 (IEC 60664-1, EN60664-1)
Electrical propertiesPotentials
Power consumption: typ. 1.725 W (To UBus and UA, intrinsic power input, no load, output 0V, up to HW04)
typ. 1.4 W (To UBus and UA, intrinsic power input, no load, output 0V, as of HW05)
max. 6.29 W (To UBus and UA, 8 current channels, output 20mA, up to HW04)
max. 5.88 W (To UBus and UA, 8 current channels, output 20mA, as of HW05)
Potentials: AxiolineF local bus supply (U
Supply voltage: 5 VDC (via bus base module)
Current draw: max. 130 mA (up to HW 04)
max. 50 mA (from HW 05)
typ. 105 mA (up to HW 04)
typ. 40 mA (from HW 05)
Power consumption: max. 0.65 W (up to HW 04)
max. 0.25 W (from HW 05)
typ. 0.525 W (up to HW 04)
typ. 0.2 W (from HW 05)
Potentials: Supply for analog modules (U
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 235 mA (8 current channels, 20 mA output)
typ. 110 mA (8 voltage channels, 10V output)
Power consumption: max. 5.64 W (8 current channels, 20 mA output)
Protective circuit: Surge protection; electronic (35 V, 0.5 s)
Reverse polarity protection; up to HW03: polarity protection diodefrom HW04: parallel diode; with external 5A fuse (for startup only)
Transient protection; Suppressor diode
Electrical isolation/isolation of the voltage ranges
Test voltage: 5V supply of the local bus (UBus) / 24V supply (I/Os): 500 VAC, 50 Hz, 1 min.
Test voltage: 5V supply of the local bus (UBus)/analog outputs: 500 VAC, 50 Hz, 1 min.
Test voltage: 5V supply of the local bus (UBus) / functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: 24 V supply (I/O)/analog outputs: 500 VAC, 50 Hz, 1 min.
Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: Analog outputs/functional ground: 500 VAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: AxiolineF connector
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
AxiolineF connector
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: DIN rail mounting
Mounting position: any (observe temperature derating)
Specifiche
ECLASSECLASS-11.0: 27242601
ECLASS-12.0: 27242601
ECLASS-13.0: 27242601
ETIMETIM 9.0: EC001596
UNSPSCUNSPSC 21.0: 32151600
Descrizione
Axioline F, Analog output module, Analog outputs: 8, 0 V ... 5 V, -5 V ... 5 V, 0 V ... 10 V, -10 V ... 10 V, 0 mA ... 20 mA, 4 mA ... 20 mA, -20 mA ... 20 mA, connection method: 2-wire, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connectors
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00182.pdf

Approvals_01195.pdf

Approvals_01203.pdf

Approvals_01303.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Approvals_01758.pdf

Approvals_01777.pdf

Approvals_01816.pdf

Approvals_01836.pdf

Approvals_01893.pdf

Approvals_01954.pdf

Data_sheet_03155.pdf

Manual_00006.pdf

Manual_00007.pdf

Manufacturer_declaration_00597.pdf

Manufacturer_declaration_01667.pdf

Manufacturer_declaration_05480.pdf

Manufacturer_declaration_05562.pdf

Manufacturer_declaration_05563.pdf

Manufacturer_declaration_14402.pdf

Package_slip_00636.pdf

Package_slip_00687.pdf

Product_information_00033.pdf

Product_information_00237.pdf

Technical_drawing_37501.pdf

Various_00004.pdf