PHOENIX CONTACT 2688093
PHOENIX CONTACTNon disponibile

AXL F CNT2 INC2 1F - Special function module

AxiolineF, Function module, Counter input for 24 V signals:2, Incremental encoder inputs:2, Symmetrical and asymmetrical encoders, Digital inputs:8, 24 VDC, Digital outputs:2, 24 VDC, transmission speed in the local bus:100 Mbps, degree of protection:IP20, including bus base module and AxiolineF connectors
Cod. Articolo: 2688093
Cod. Fornitore: 2688093
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/3f783436b27c3846a361ee861b282789/-S204x204-FJPG
Width: 53.6 mm
Height: 126.1 mm
Depth: 54 mm
Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
InterfacesAxiolineFlocal bus
Number of interfaces: 2
Connection method: Bus base module
Transmission speed: 100 Mbps
System propertiesModule
ID code (hex): none
Input address area: 28 Byte
Output address area: 28 Byte
Required parameter data: 115 Byte
Required configuration data: 7 Byte
Input dataDigital
Input name: Digital inputs
Description of the input: EN 61131-2, type 3
Number of inputs: 8 (CNT: G1, G2, Dir1, Dir2; INC: Ref1, Ref2, L1, L2)
Connection method: Push-in connection
Connection technology: 1-conductor (optional 2, 3-conductor)
Input voltage range "0" signal: -3 VDC ... 5 VDC
Input voltage range "1" signal: 11 VDC ... 30 VDC
Nominal input voltage UIN: 24 VDC
Nominal input current at UIN: 2.5 mA (per channel)
Encoder
Number of inputs: 2 (A1, /A1, B1, /B1, Z1, /Z1; A2, /A2, B2, /B2, Z2, /Z2)
Input name: Incremental encoder inputs
Encoder signals: Symmetrical and asymmetrical encoders
Cable length: max. 30 m
Counter
Input name: Counter input for 24 V signals
Description of the input: EN 61131-2, type 3
Connection method: Push-in connection
Number of inputs: 2 (S1, S2)
Input voltage: 24 VDC
Input voltage range "0" signal: -3 VDC ... 5 VDC
Input voltage range "1" signal: 11 VDC ... 30 VDC
Input frequency: max. 300 kHz (1 channel wired)
max. 100 kHz (more than one channel wired or Z signal monitoring via the firmware)
Input current: 2.5 mA (per channel)
Resolution: 32 bits
Permissible cable length: max. 30 m
Output dataDigital
Output name: Digital outputs
Connection method: Push-in connection
Connection technology: 1-conductor
Number of outputs: 2 (Out1, Out2)
Protective circuit: Short-circuit protection
Overload protection
Output voltage: 24 VDC
Maximum output current per channel: 500 mA
Nominal output voltage: 24 VDC
Nominal load, inductive: max. 12 VA (1.2 H, 48 Ω, with nominal voltage)
Nominal load, lamp: max. 12 W (at nominal voltage)
Nominal load, ohmic: max. 12 W (48 Ω, with nominal voltage)
Product propertiesType: block modular
Product type: I/O component
Product family: AxiolineF
Mounting position: any (no temperature derating)
Scope of delivery: including bus base module and AxiolineF connectors
Insulation characteristics
Overvoltage category: II (IEC 60664-1, EN60664-1)
Pollution degree: 2 (IEC 60664-1, EN60664-1)
Electrical propertiesMaximum power dissipation for nominal condition: 0.6 W
Encoder
Number: 2 (UE1, UE2)
2 (US1, US2)
max. 2 (A, /A, B, /B, (Z, /Z))
max. 2 (A, B, (Z))
Nominal output voltage: 5 VDC
24 VDC
Voltage range: 5 VDC ... 5.5 VDC
19.2 VDC ... 30 VDC
Current carrying capacity: max. 250 mA
typ. 500 mA
Protective circuit: Short-circuit protection; electronic
Designation: Symmetrical incremental encoders
Asymmetrical incremental encoder
Type of connection of signals: Push-in connection
Encoder supply voltage: 5 VDC
24 VDC
Signal voltage level: Differential signal (signal – inverted signal)±0.5V, minimum; ±6V, maximum
Low ≤ 2.5 V, high ≥ 3.5 V (up to 27 V, maximum)
Common mode voltage range signal - ground: -10 V ... 13.2 V
Input frequency: max. 300 kHz (1 channel wired)
max. 100 kHz (more than one channel wired or Z signal monitoring via the firmware)
max. 300 kHz (1 channel wired)
max. 100 kHz (more than one channel wired or Z signal monitoring via the firmware)
Potentials: AxiolineF local bus supply (U
Supply voltage: 5 VDC (via bus base module)
Current draw: max. 120 mA
typ. 100 mA
Power consumption: max. 0.6 W
typ. 0.5 W
Potentials: Feed-in of supply voltage (U
Supply voltage: 24 VDC
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 2.5 A (dependent on the encoder or sensor type used and the load on the digital output.)
Power consumption: max. 60 W (of which 1.6W internal losses)
Protective circuit: Surge protection; electronic (35 V, 0.5 s)
Reverse polarity protection; parallel diode; with external 5A fuse (only for commissioning)
Electrical isolation/isolation of the voltage ranges
Test voltage: 5V supply of the local bus (UBus) / 24V supply (I/Os): 500 VAC, 50 Hz, 1 min.
Test voltage: 5V supply of the local bus (UBus) / functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: 24V supply (I/O) / functional ground: 500 VAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: AxiolineF connector
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
AxiolineF connector
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the “AxiolineF: system and installation” user manual.
Conductor cross section, rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section AWG: 24 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: DIN rail mounting
Mounting position: any (no temperature derating)
Specifiche
ECLASSECLASS-11.0: 27242605
ECLASS-12.0: 27242605
ECLASS-13.0: 27242605
ETIMETIM 9.0: EC001601
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01195.pdf

Approvals_01203.pdf

Approvals_01303.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Approvals_01777.pdf

Approvals_01816.pdf

Approvals_01836.pdf

Approvals_01893.pdf

Data_sheet_03156.pdf

Manual_00007.pdf

Manual_00006.pdf

Manual_00141.pdf

Manufacturer_declaration_00616.pdf

Manufacturer_declaration_01562.pdf

Manufacturer_declaration_05480.pdf

Manufacturer_declaration_05562.pdf

Manufacturer_declaration_05563.pdf

Package_slip_00709.pdf

Product_information_00033.pdf

Product_information_00238.pdf

Technical_drawing_37502.pdf

Various_00004.pdf