AXL E PB IOL8 DI4 M12 6P - Communication module

AxiolineE, PROFIBUS DP, M12 fast connection technology, IO-Link ports Class A: 4, connection method: M12 fast connection technology, connection technology: 3-conductor, IO-Link ports Class B: 4, connection method: M12 fast connection technology, connection technology: 3-conductor, Digital inputs at pin 2 for class A ports: 4, 24 VDC, connection technology: 3-conductor, Plastic housing, degree of protection: IP65/IP67
Cod. Articolo: 2701503
Cod. Fornitore: 2701503
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/5b337e318ca1ed41a970b074b0b1c553/-S204x204-FJPG
Width: 60 mm
Height: 185 mm
Depth: 30.5 mm
Drill hole spacing: 198.5 mm
Note on dimensions: The height is 212 mm including fixing clips.
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Material specificationsHousing material: Pocan®
Color: anthracite
InterfacesPROFIBUS DP
Number of interfaces: 2
No. of channels: 2
Connection method: M12 fast connection technology
Note on the connection method: B-coded
Number of positions: 5
Transmission speed: 9.6 kbps ... 12 Mbps (Automatic baud rate detection)
Transmission physics: PROFIBUS-DP-compliant copper cable
Address area assignment: 1 ... 126, adjustable
PROFIBUS DPâۉ€¹
Equipment type: PROFIBUS slave
System-specific protocols: PROFIBUS protocols DP V1
System propertiesModule
ID code (hex): 0E57
Input address area: min. 2 Byte
max. 162 Byte (Dependent on configuration)
Output address area: min. 2 Byte
max. 162 Byte (Dependent on configuration)
Input dataDigital
Input name: Digital inputs at pin 2 for class A ports
Description of the input: IEC 61131-2 type 1
Number of inputs: 4
Connection method: M12 connector, X01 ... X04 have double occupancy
Connection technology: 3-conductor
Input voltage range "0" signal: -0.3 VÂDC ... 5 VÂDC
Input voltage range "1" signal: 15 VÂDC ... 30 VÂDC
Nominal input voltage UIN: 24 VÂDC
Nominal input current at UIN: typ. 3 mA
Sensor current per channel: max. 200 mA (from L+/L-)
Total sensor current: max. 1.6 A (from L+/L-)
Input frequency: 0.5 kHz
Input filter time: < 1000 µs
Protective circuit: Overload protection, short-circuit protection of sensor supply
Digitalâۉ€¹
Description of the input: IO-Link ports in digital input (DI) mode
Number of inputs: max. 8 (EN 61131-2 type 1)
Connection method: M12 connector, X01 ... X04 have double occupancy
Connection technology: 3-conductor
Nominal input voltage UIN: 24 VÂDC
Input voltage range "0" signal: -0.3 VÂDC ... 5 VÂDC
Input voltage range "1" signal: 15 VÂDC ... 30 VÂDC
Nominal input current: typ. 3 mA
Sensor current per channel: max. 200 mA (from L+/L-)
Total sensor current: max. 1.6 A (from L+/L-)
Input filter time: < 1000 µs
Input frequency: 0.5 kHz
Protective circuit: Overload protection; yes
Short-circuit protection for the sensor supply; yes
IO-Link
Number of ports: 4
Connection method: M12 fast connection technology
Connection technology: 3-conductor
Port type: Class A
Cycle Time: min. 2 ms (MasterCycleTime: PDInput* + PDOutput* + OnReqData* < = 17 Bytes, COM3; * see "IO-Link Interface and System Specification V1.1.2")
IO-Linkâۉ€¹
Number of ports: 4
Connection method: M12 fast connection technology
Connection technology: 3-conductor
Port type: Class B
Cycle Time: min. 2 ms (MasterCycleTime: PDInput* + PDOutput* + OnReqData* < = 17 Bytes, COM3; * see "IO-Link Interface and System Specification V1.1.2")
Output dataDigital
Output description: IO-Link ports in digital output (DO) mode
Connection method: M12 connector, X01 ... X04 have double occupancy
Connection technology: 3-conductor
Number of outputs: max. 8
Nominal output voltage: 24 VÂDC
Maximum output current per channel: 150 mA
Maximum output current per module: 1.2 A
Nominal load, ohmic: 3.6 W (160 Ω, at nominal load)
Nominal load, inductive: 3.6 VA (0.8ÂH, 160ÂΩ, at nominal load)
Signal delay: max. 150 µs (when switched on)
max. 200 µs (when switched off)
Switching rate: 1 per second, maximum (at nominal inductive load)
5500 per second, maximum (at nominal ohmic load)
Limitation of the voltage induced on circuit interruption: -15 VÂDC
Output voltage when switched off: max. 1 V
Output current when switched off: max. 300 µA
Protective circuit: Overload protection; yes
Short-circuit protection; yes
Behavior with overload: Shutdown with automatic restart
Product propertiesType: Stand-Alone
Product type: I/O component
Product family: AxiolineÂE
Electrical propertiesPotentials
Voltage supply US: 24 VÂDC
Power supply at US: max. 4 A
Current consumption from US: typ. 8 mA
max. 1.2 A
Supply: IO-Link
Nominal voltage for I/O supply: 24 VÂDC
Nominal current for every IO-Link port: max. 150 mA (at C/Q (pin 4), maximum of 1.6 A over all 8 IO-Link C/Q and L+ cables)
max. 200 mA (at L+/L- (pin 1 and pin 3), during startup, up to 1.6 A for short periods)
max. 2 A (at UA (IO-Link B ports, pin 2 and pin 5))
Permissible cable length: < 20 m
Protective circuit: Overload protection; yes
Supply: Module electronics and sensors
Designation: Supply of module electronics and sensors (US)
Connection method: M12 connector (T-coded)
Number of positions: 4
Supply voltage: 24 VÂDC
Supply voltage range: 19.5 VÂDC ... 31.2 VÂDC (including all tolerances, including ripple)
Current consumption: typ. 170 mA ±15Â% (at 24 V DC)
max. 12 A
Supply: Actuators
Designation: Supply of actuators (UA)
Connection method: M12 connector (T-coded)
Number of positions: 4
Supply voltage: 24 VÂDC
Supply voltage range: 18 VÂDC ... 31.2 VÂDC (including all tolerances, including ripple)
Current consumption: typ. 30 mA ±15Â% (at 24 V DC)
max. 12 A
Electrical isolation/isolation of the voltage ranges
Test voltage: 24 V supply (communications power and sensor supply, IO-Link ports)/bus connection: 500 VÂAC, 50 Hz, 1 min.
Test voltage: 24 V supply (communications power and sensor supply, IO-Link ports)/FE: 500 VÂAC, 50 Hz, 1 min.
Test voltage: Bus connection / FE: 500 VÂAC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/24 V supply (communications power and sensor supply, IO-Link ports): 500 VÂAC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/bus connection: 500 VÂAC, 50 Hz, 1 min.
Test voltage: 24 V supply (actuator supply)/FE: 500 VÂAC, 50 Hz, 1 min.
Connection dataConnection method: M12 connector
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP65/IP67
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000Âm above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000Âm above sea level)
Ambient temperature (storage/transport): -25°C ... 85°C
Permissible humidity (operation): 5 % ... 95 %
Permissible humidity (storage/transport): 5 % ... 95 %
Standards and regulationsProtection class: III (IEC 61140, ENÂ61140, VDEÂ0140-1)
MountingMounting type: Wall mounting
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00039.pdf

Application_note_00040.pdf

Application_note_00180.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Approvals_01239.pdf

Data_sheet_03275.pdf

Manual_00152.pdf

Manual_00167.pdf

Manufacturer_declaration_00730.pdf

Manufacturer_declaration_02237.pdf

Manufacturer_declaration_05478.pdf

Manufacturer_declaration_14576.pdf

Package_slip_00659.pdf

Package_slip_00670.pdf

Technical_drawing_37708.pdf

Various_00004.pdf