PHOENIX CONTACT 2702671
PHOENIX CONTACTNon disponibile

AXL F PM EF 1F - Special function module

AxiolineF, power measurement module, input voltage: up to 400VAC (phase/neutral) or 690VAC (phase/phase), input current: up to 5AAC, transmission speed in local bus: 100Mbps, degree of protection: IP20 , including bus base module and AxiolineF connectors
Cod. Articolo: 2702671
Cod. Fornitore: 2702671
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/80d302c6dd37e74dab200fad48709c28/-S204x204-FJPG
Width: 53.6 mm
Height: 126.1 mm
Depth: 65.5 mm
Note on dimensions: The depth applies when a TH35-7.5 DIN rail is used (in accordance with EN60715).
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
InterfacesAxiolineFlocal bus
Number of interfaces: 2
Connection method: Bus base module
Transmission speed: 100 Mbps
System propertiesModule
Input address area: 64 Byte
Output address area: 0 Byte
Required parameter data: 52 Byte
Required configuration data: 7 Byte
Product propertiesType: block modular
Product type: I/O component
Product family: AxiolineF
Mounting position: any (no temperature derating)
Operating mode: Process data mode with 32 words
Insulation characteristics
Pollution degree: 2
Electrical propertiesPotentials: AxiolineF local bus supply (U
Supply voltage: 5 VDC (via bus base module)
Current draw: max. 80 mA
typ. 73 mA
Power consumption: max. 400 mW
typ. 365 mW
Electrical isolation/isolation of the voltage ranges
Test voltage: 5V supply for local bus (UBus) / peripheral range AC: 4 kV, 50 Hz, 1 min.
Test voltage: 5V supply of the local bus (UBus) / functional ground: 500 VAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: AxiolineF connector
Note on the connection method: Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Only use reinforced or double-insulated conductors with a conductor cross section of 1.5mm².
AxiolineF connector
Connection method: Push-in connection
Note on the connection method: Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Only use reinforced or double-insulated conductors with a conductor cross section of 1.5mm².
Conductor cross section, rigid: 1.5 mm²
Conductor cross section, flexible: 1.5 mm²
Conductor cross section AWG: 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 60°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (Up to 3000m above sea level, from HW01)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -40°C ... 85°C
Permissible humidity (operation): 5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 5 % ... 95 % (non-condensing)
Standards and regulationsProtection class: II
MountingMounting type: DIN rail mounting
Mounting position: any (no temperature derating)
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_01227.pdf

Approvals_01228.pdf

Approvals_01759.pdf

Data_sheet_03369.pdf

Manual_00006.pdf

Manual_00007.pdf

Manual_00188.pdf

Manufacturer_declaration_01058.pdf

Manufacturer_declaration_01833.pdf

Manufacturer_declaration_05480.pdf

Manufacturer_declaration_05562.pdf

Manufacturer_declaration_05563.pdf

Package_slip_00751.pdf

Product_information_00033.pdf

Product_information_00327.pdf

Technical_drawing_37863.pdf

Various_00004.pdf