Dimensions | Width: 45 mm Height: 130 mm Depth: 115 mm
|
Notes | General: Support by phone or on-site (fee is charged)
|
Material specifications | Housing material: Polycarbonate fiber reinforced
|
Mounting | Mounting type: DIN rail mounting
|
Interfaces | Ethernet (RJ45) Connection method: RJ45 Note on the connection method: Auto negotiation and autocrossing Transmission speed: 10/100 Mbps Transmission physics: Copper Transmission length: 100 m (per segment) Signal LEDs: Data receive, link status No. of channels: 8 (RJ45 ports)
|
Product properties | Type: Book type Product type: Switch Product family: Managed NAT Switch 2000 MTTF: 507.8 Years (SN29500 standard, temperature25°C, operating cycle21%) 246.55 Years (SN29500 standard, temperature40°C, operating cycle34.25%) 56.66 Years (SN29500 standard, temperature55°C, operating cycle100%) Special properties: 1:1-NAT, Virtual NAT, IP-Masquerading Signal delay: ⥠6.5 µs (Store and Forward mode, 10/100 Mbps, depending on the frame size) Insulation characteristics Protection class: III (VDE0106) Switch functions Diagnostic functions: RMON History LLDP (Link Layer Discovery Protocol) SNMP-Traps N:1-Portmirroring ACD (Address Conflict Detection) SysLog CRC-Surveillance Basic functions: Router for standard routing, NAT, 1:1-NAT and port forwarding NAT functions: 1:1-NAT Virtual-NAT IP-Masquerading Port forwarding PROFINET conformance class: Conformance-Class A Filter functions: Quality of Service (8 priority classes) Class of Service DiffServ/DSCP Port-Priorisierung VLAN (up to 8 VLANs) IGMP Snooping/Querier (v1/v2) Auto-Query-Port Extended Multicast Filtering IP parameterization: DHCP-Client DHCP server (port based) BootP MAC address table: 8k Management: Web-based management (HTTP/HTTPS) Role-based user management (LDAP, RADIUS) SNMPv1/v2/v3 Command Line Interface (Telnet, SSH) Redundancy: MRP (Media Redundancy Protocol) RSTP (Rapid Spanning Tree Protocol) Status and diagnostic indicators: LEDs: US (power supply), 2 LEDs per Ethernet port (Link/Activity and Speed) Time synchronization: SNTP (Simple Network Time Protocol) Security functions Basic functions: Router for standard routing, NAT, 1:1-NAT and port forwarding
|
Electrical properties | Local diagnostics: US Supply voltage Green LED LNK/ACT Link status Green LED SPD Data transmission speed Green LED Maximum power dissipation for nominal condition: 4.86 W (At US = 18 V DC and 60°C ambient temperature) Test voltage: 500 VDC Test section: for one minute 500 VDC Transmission medium: Copper Supply Supply voltage (DC): 24 VDC (single) Supply voltage range: 18 VDC ... 32 VDC Power supply connection: via COMBICON, max. conductor cross section 1.5 mm² Residual ripple: 3.6 VPP (within the permitted voltage range) Max. current consumption: 0.35 A (At US = 18 V DC and 60°C ambient temperature) Typical current consumption: 180 mA (at US = 24VDC and 25°C ambient temperature) Current consumption: 180 mA
|
Connection data | Connection method: Screw connection Note on the connection method: Use only copper connecting cables providing the permitted temperature range (-40°C ... 75°C). Conductor cross section, rigid: 0.08 mm² ... 1.5 mm² Conductor cross section, flexible: 0.08 mm² ... 1.5 mm² Conductor cross section AWG: 28 ... 16 Stripping length: 7 mm
|
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): 0°C ... 60°C Ambient temperature (storage/transport): -40°C ... 85°C Permissible humidity (operation): 10 % ... 95 % (non-condensing) Permissible humidity (storage/transport): 10 % ... 95 % (non-condensing) Shock (operation): 30g (EN60068-2-27) Vibration (operation): 2g, according to IEC 60068-2-6 Air pressure (operation): 86 kPa ... 108 kPa (1500m above sea level) Air pressure (storage/transport): 86 kPa ... 108 kPa
|
Standards and regulations | Free from substances that could impair the application of coating: Yes
|
Approvals | Conformity/Approvals UL, USA: UL 61010-1, Ed.3 / UL 61010-2-201, Ed.1 UL, Canada: CSA C22.2 NO.61010-2-201:14, Ed.1 / CSA C22.2 NO.61010-1-12, Ed.3
|
EMC data | Conformance with EMC directives: EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A EN 61000-6-2 EN 61000-4-5 (surge) Criterion B EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A EN 61000-6-2 EN 61000-6-4 (interference) ClassA EN 61000-6-2 EN 61000-6-4 (conducted interference) ClassA Noise immunity: EN 61000-6-2 Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU Noise emission: EN 61000-6-4
|
System properties | Functionality Basic functions: Router for standard routing, NAT, 1:1-NAT and port forwarding
|
Signaling | Status display: LEDs: US (power supply), 2 LEDs per Ethernet port (Link/Activity and Speed)
|