Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 2759870
PHOENIX CONTACTNon disponibile

IBS INBC METER/S - Installation remote bus cable

By the meter, Installation remote bus cable, INTERBUS, shielded, PUR, may green RAL 6017, 9-wire (3 x 2 x 0.25 mm2 + 3 x 1 mm2), color single wire: green-yellow, white-brown, gray-pink, red, blue, green/yellow, highly flexible, welding sputter-resistant
Cod. Articolo: 2759870
Cod. Fornitore: 2759870
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Remote bus cable
Number of positions: 9
Electrical propertiesTransmission medium: Copper
Cable/lineNumber of positions: 9
Shielded: yes
Conductor structure: 3 x 2 x 0.25 mm² + 3 x 1 mm²
Signal speed: 0.66 c
Conductor structure signal line: 32x 0.10 mm
Conductor cross section: 3x 2x 0.25 mm² (Data)
3x 1 mm² (Supply)
Wire diameter incl. insulation: 1 mm (Data)
1.7 mm (Supply)
External cable diameter: 7.7 mm +0.2mm
Outer sheath, material: PUR
External sheath, color: may green RAL 6017
Conductor material: Bare Cu litz wires
Material wire insulation: PE
Single wire, color: green-yellow, white-brown, gray-pink, red, blue, green/yellow
Twisted pairs: 2 cores to the pair
Overall twist: 3 pairs and 3 wires to form the core
Insulation resistance: ≥ 5 GΩ*km (Data)
≥ 5 GΩ*km (Supply)
Coupling resistance: < 250.00 mΩ/m (at 30 MHz)
Loop resistance: ≤ 159.80 Ω/km (Data)
≤ 19.50 Ω/km (Supply)
Wave impedance: 110 Ω ±20Ω (at 64kHz)
95 Ω ±15Ω (at >1MHz)
Cable capacity: ≤ 60 nF/km (At 800 Hz)
Nominal voltage, cable: 250 V (Peak value, not for high-power applications)
450 V (Supply)
Test voltage Core/Core: 1500 Vrms
Test voltage Core/Shield: 1000 Vrms
Minimum bending radius, fixed installation: 7.5 x D
Minimum bending radius, flexible installation: 15 x D
Near end crosstalk attenuation (NEXT): ≥ 61 dB (at 772kHz)
≥ 59 dB (with 1 MHz)
≥ 55 dB (at 2МHz)
≥ 50 dB (at 4 МHz)
≥ 46 dB (at 8МHz)
≥ 44 dB (at 10 MHz)
≥ 41 dB (at 16 MHz)
≥ 40 dB (at 20МHz)
Shield attenuation: ≤ 10 dB/km (at 256kHz)
≤ 25 dB/km (at 772kHz)
≤ 28 dB/km (with 1 MHz)
≤ 69 dB/km (at 4 МHz)
≤ 12 dB/km (at 10 MHz)
≤ 15.5 dB/km (at 16 MHz)
≤ 17.2 dB/km (at 20МHz)
Flame resistance: according to VDE0472, Part 804, test type B
according to IEC 60332-1
Ambient temperature (operation): -40°C ... 80°C (cable, fixed installation)
-30°C ... 70°C (Cable, flexible installation)
Specifiche
ECLASSECLASS-11.0: 27061801
ECLASS-12.0: 27061801
ECLASS-13.0: 27061801
ETIMETIM 9.0: EC003249
UNSPSCUNSPSC 21.0: 26121600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00016.pdf

Data_sheet_03442.pdf

Manufacturer_declaration_01381.pdf

Manufacturer_declaration_02425.pdf