PHOENIX CONTACT 2800885
PHOENIX CONTACTNon disponibile

CB TM2 6A M1 P - Thermomagnetic device circuit breaker

Thermomagnetic device circuit breaker, 2-pos., tripping characteristic M1 (medium-blow), 2 changeover contacts, plug for base element.
Cod. Articolo: 2800885
Cod. Fornitore: 2800885
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
NotesGeneral: When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly.
Product propertiesType: Male
Product type: Thermomagnetic device circuit breakers
Product family: CBTM
Number of positions: 2
No. of channels: 1
Insulation characteristics
Degree of pollution: 2
Electrical propertiesNo. of channels: 1
Fuse type: Automatic device
General
Rated voltage: 80 VDC (IEC 60934)
80 VDC (UL 1077)
80 VDC (UL 508 - with plug-in base)
240 VAC (Ue according to IEC 60934)
277 VAC (UL 1077)
277 VAC (UL 508 - with plug-in base)
Rated insulation voltage Ui: 277 VAC (UL 1077)
250 VAC (IEC 60934)
Rated current IN: 6 A (IEC 60934)
6 A AC (inductive load according to UL 1077)
6 ADC (low-induction load according to UL 1077)
6 A AC (inductive load according to UL 508 - with plug-in base)
6 ADC (low-induction load according to UL 508 - with plug-in base)
Rated surge voltage: 2.5 kV (Increased insulation in actuation area)
Insulation resistance Riso: > 100 MΩ (500 V DC)
Auxiliary circuit: 277 VAC/0.5 A(Low-induction)
277 VAC/1 A(Low-induction, maximum of 2000 cycles)
50 VDC/1 A(Low-induction)
Type of actuation: S type
Tripping method: TM (thermomagnetic)
Tripping level: Trip-free mechanism (positive)
Device resistance: 50 mΩ
Required backup fuse: ≥ 24 A (I > Icn)
Rated short-circuit switching capacity Icn: 400 A (240VAC)
600 A (80 V DC)
Short-circuit switching capacity: 1000 A AC (277VAC)
1000 ADC (50 V DC)
Dielectric strength: 3000 VAC (Actuation area)
1500 VAC (Main to auxiliary circuit)
1500 VAC (Open main circuit)
1000 VAC (Open auxiliary circuit)
1500 VAC (Position to position)
Switching cycles, max.: 6000 (240VAC / 1xIn)
3000 (80 V DC/1 x In)
Fuse: M1 (normal blow)
Power dissipation: 1.8 W (in nominal operation per channel)
Voltage drop: 0.29 V (at 1 x In)
Auxiliary contact
Minimum operating voltage Umin DC: 10 V
Maximum operating voltage Umax DC: 240 V
Maximum operating voltage Umax. AC: 240 V
Minimum operating current Imin: 10 mA
Max. operating current Imax: 1 A
Connection dataConnection method: pluggable
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/5a95d2793fda0c4fa8da47431604e676/-S204x204-FJPG
Width: 24.6 mm
Height: 45 mm
Depth: 52 mm
Material specificationsFlammability rating according to UL 94: V-0
Insulating material group: II
Mechanical propertiesMechanical data
Open side panel: No
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP30 (Actuation area)
Ambient temperature (operation): -30°C ... 60°C
Ambient temperature (storage/transport): -40°C ... 80°C
Humidity test: 240 h, 95 % RH, 40°C
Shock (operation): 30g (IEC 60068-2-27, Test Ea)
Vibration (operation): 8g (IEC 60068-2-6, Test Fc)
ApprovalsUL approval
Identification: UL Listed UL508
UL/C-UL Recognized UL 1077
CSA
Identification: CSA CAN/CSA-C22.2 No. 235-04
Shipbuilding approval
Identification: DNV GL
Standards and regulationsStandards/specifications: EN60934
MountingMounting type: on base element
Connection method: pluggable
Specifiche
ECLASSECLASS-11.0: 27140401
ECLASS-12.0: 27140401
ECLASS-13.0: 27140401
ETIMETIM 9.0: EC003538
UNSPSCUNSPSC 21.0: 39121400
Descrizione
Thermomagnetic device circuit breaker, 2-pos., tripping characteristic M1 (medium-blow), 2 PDT contacts, plug for base element.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Approvals_00005.pdf

Approvals_00053.pdf

Approvals_00970.pdf

Manufacturer_declaration_00682.pdf

Manufacturer_declaration_02070.pdf

Package_slip_00241.pdf

Technical_drawing_38442.pdf

Various_00100.pdf

Various_00001.pdf