PHOENIX CONTACT 2819574
PHOENIX CONTACTNon disponibile

IB IL SSI-IN-PAC - Special function module

Inline measurement terminal block for absolute encoders, complete with accessories (connector and labeling field), 1 input for absolute rotation or position measurement systems, with SSI interface
Cod. Articolo: 2819574
Cod. Fornitore: 2819574
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/20a984302842e949b5ce7beb58df3766/-S204x204-FJPG
Width: 12.2 mm
Height: 135 mm
Depth: 71.5 mm
NotesUtilization restriction
CCCex note: Use in potentially explosive areas is not permitted in China.
InterfacesInline local bus
Connection method: Inline data jumper
Transmission speed: 500 kbps
Transmission physics: Copper
System propertiesModule
ID code (dec.): 95
ID code (hex): 5F
Length code (hex): 02
Length code (dec): 02
Process data channel: 32 bit
Input address area: 4 Byte
Output address area: 4 Byte
Register length: 4 Byte
Required parameter data: 6 Byte
Required configuration data: 5 Byte
Input dataAbsolute encoder
Number of inputs: 1
Adjustable resolution: 25 bit (maximum)
Transmission frequency: 100 kHz
200 kHz
400 kHz
800 kHz
1 MHz
Digital
Connection technology: Spring-cage connection
Output dataDigital
Number of outputs: 1
Product propertiesType: modular
Product type: I/O component
Product family: Inline
Electrical propertiesSupply
Drawing encoder supply voltage: Main circuit UM
Encoder supply voltage: 5 VDC
Encoder supply current: max. 250 mA
I/O voltage: 24 VAC
Max. current consumption: 35 mA (typical)
Potentials: Communications power (U
Supply voltage: 7.5 VDC (via voltage jumper)
Current draw: max. 28 mA
Potentials: Main circuit supply (U
Supply voltage: 24 VDC (via voltage jumper)
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 66 mA
Connection dataConnection technology
Connection name: Inline connector
Conductor connection
Connection method: Spring-cage connection
Conductor cross section rigid: 0.08 mm² ... 1.5 mm²
Conductor cross section flexible: 0.08 mm² ... 1.5 mm²
Conductor cross section AWG: 28 ... 16
Stripping length: 8 mm
Inline connector
Connection method: Spring-cage connection
Conductor cross section, rigid: 0.08 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.08 mm² ... 1.5 mm²
Conductor cross section AWG: 28 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Ambient temperature (operation): -25°C ... 55°C
Ambient temperature (storage/transport): -25°C ... 85°C
Permissible humidity (operation): 75 % ... 85 %
Permissible humidity (storage/transport): 75 % ... 85 %
MountingMounting type: DIN rail mounting
Specifiche
ECLASSECLASS-11.0: 27242605
ECLASS-12.0: 27242605
ECLASS-13.0: 27242605
ETIMETIM 9.0: EC001601
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00104.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Data_sheet_03469.pdf

Manual_00085.pdf

Manufacturer_declaration_00895.pdf

Manufacturer_declaration_01756.pdf

Manufacturer_declaration_15119.pdf

Package_slip_01397.pdf

Technical_drawing_38642.pdf

Various_00038.pdf