IB IL TEMP 2 UTH-PAC - Temperature module

Inline, Temperature measurement terminal, Analog UTH inputs: 2 (Thermocouples or linear voltage), connection technology: 2-conductor, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field
Cod. Articolo: 2861386
Cod. Fornitore: 2861386
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
DimensionsDimensional drawing: https://dam-mdc.phoenixcontact.com/rendition/156443151564/8f49d2b498684640a945b59e148b2698/-S204x204-FJPG
Width: 12.2 mm
Height: 136.8 mm
Depth: 71.5 mm
Note on dimensions: Housing dimensions
NotesUtilization restriction
CCCex note: Use in potentially explosive areas is not permitted in China.
InterfacesInline local bus
Number of interfaces: 2
Connection method: Inline data jumper
Transmission speed: 500 kbps
System propertiesModule
ID code (dec.): 127
ID code (hex): 7F
Length code (hex): 02
Length code (dec): 02
Process data channel: 32 bit
Input address area: 4 Byte
Output address area: 4 Byte
Register length: 32 bit
Required parameter data: 6 Byte
Required configuration data: 4 Byte
Input dataAnalog
Input name: Analog UTH inputs
Description of the input: Inputs for thermocouples or linear voltage
Number of inputs: 2 (Thermocouples or linear voltage)
Connection method: Inline connector
Connection technology: 2-conductor
Note regarding the connection technology: Shielded compensating line for TC with encapsulated sensors
A/D conversion time: typ. 120 µs (per channel)
Sensor types that can be used (TC): U, T, L, J, E, K, N, S, R, B, C, W, HK
Measuring principle: Successive approximation
Measured value representation: 16 bits (15 bits + sign bit)
Process data update: max. 30 ms (For both channels)
Protective circuit: Surge protection (TC channels); up to ±40V
Product propertiesType: modular
Product type: I/O component
Product family: Inline
Scope of delivery: including Inline connector and labeling field
Operating mode: Process data operation with 2 words
Diagnostics messages: Failure of the internal I/O supply I/O error message sent to the bus coupler
Failure of or insufficient communications power UL I/O error message sent to the bus coupler
I/O error Error message in the process data
User error Error message in the process data
Electrical propertiesMaximum power dissipation for nominal condition: 0.59 W
Potentials
Power consumption: typ. 587 mW
max. 882 mW
Potentials: Communications power (U
Supply voltage: 7.5 VDC (via voltage jumper)
Current draw: max. 60 mA
typ. 43 mA
Potentials: Supply of analog modules (U
Supply voltage: 24 VDC (via voltage jumper)
Supply voltage range: 19.2 VDC ... 30 VDC (including all tolerances, including ripple)
Current draw: max. 18 mA
typ. 11 mA
Electrical isolation/isolation of the voltage ranges
Test voltage: 7.5 V supply (bus logics)/24 V analog supply (analog I/O): 500 VAC, 50 Hz, 1 min.
Test voltage: 7.5V supply (bus logic)/functional ground: 500 VAC, 50 Hz, 1 min.
Test voltage: 24V analog supply (analog I/O)/functional ground: 500 VAC, 50 Hz, 1 min.
Connection dataConnection technology
Connection name: Inline connector
Conductor connection
Connection method: Spring-cage connection
Conductor cross section rigid: 0.08 mm² ... 1.5 mm²
Conductor cross section flexible: 0.08 mm² ... 1.5 mm²
Conductor cross section AWG: 28 ... 16
Stripping length: 8 mm
Inline connector
Connection method: Spring-cage connection
Conductor cross section, rigid: 0.08 mm² ... 1.5 mm²
Conductor cross section, flexible: 0.08 mm² ... 1.5 mm²
Conductor cross section AWG: 28 ... 16
Stripping length: 8 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -25°C ... 55°C
Degree of protection: IP20
Air pressure (operation): 70 kPa ... 106 kPa (up to 3000m above sea level)
Air pressure (storage/transport): 70 kPa ... 106 kPa (up to 3000m above sea level)
Ambient temperature (storage/transport): -25°C ... 85°C
Permissible humidity (operation): 10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport): 10 % ... 95 % (non-condensing)
Standards and regulationsProtection class: III (IEC 61140, EN61140, VDE0140-1)
MountingMounting type: DIN rail mounting
Specifiche
ECLASSECLASS-11.0: 27242601
ECLASS-12.0: 27242601
ECLASS-13.0: 27242601
ETIMETIM 9.0: EC001596
UNSPSCUNSPSC 21.0: 32151600
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00104.pdf

Application_note_00102.pdf

Application_note_00101.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_00156.pdf

Approvals_01146.pdf

Approvals_01166.pdf

Approvals_01174.pdf

Approvals_01216.pdf

Approvals_01295.pdf

Approvals_01555.pdf

Data_sheet_03509.pdf

Manual_00085.pdf

Manufacturer_declaration_00929.pdf

Manufacturer_declaration_01903.pdf

Manufacturer_declaration_15217.pdf

Package_slip_01402.pdf

Product_information_00033.pdf

Product_information_00418.pdf

Technical_drawing_38899.pdf

Various_00038.pdf