Input data | AC operation Input voltage range: 100 VAC ... 240 VAC -15%...+10% Electric strength, max.: 300 VAC 60 s Typical national grid voltage: 120 VAC 230 VAC Voltage type of supply voltage: AC/DC Inrush current: typ. 11.4 A (at 25°C) Inrush current integral (I2t): < 0.2 A2s Inrush current limitation: < 11.4 A Frequency range (fN): 50 Hz ... 60 Hz -10%...+10% Mains buffering time: typ. 48 ms (120VAC) typ. 48 ms (230 V AC) Current consumption: 1 A (100VAC) 0.85 A (120VAC) 0.46 A (230 V AC) 0.44 A (240VAC) Nominal power consumption: 96.3 VA Protective circuit: Transient surge protection; Varistor Typical response time: 300 ms Input fuse: 3.15 A (slow-blow, internal) Recommended breaker for input protection: 6 A ... 16 A (Characteristic B, C or comparable) Discharge current to PE: < 0.25 mA (264VAC, 60Hz) < 0.17 mA DC operation Input voltage range: 110 VDC ... 250 VDC -20%...+40% Voltage type of supply voltage: AC/DC Current consumption: 0.92 A (110VDC) 0.4 A (250VDC)
|
Output data | Efficiency: typ. 91.5 % (120VAC) typ. 92.5 % (230 V AC) Nominal output voltage: 12 VDC Setting range of the output voltage (USet): 12 VDC ... 15 VDC (constant capacity) Nominal output current (IN): 7.5 A Dynamic Boost (IDyn.Boost): 12.75 A (â¤60°C (5s)) Feedback voltage resistance: ⤠25 VDC Protection against overvoltage at the output (OVP): ⤠18 VDC Control deviation: < 0.3 % (Static load change 10% ... 90%) < 3 % (Dynamic load change 10% ... 90%, (10 Hz)) < 0.1 % (change in input voltage ±10 %) Residual ripple: < 35 mVPP (with nominal values) Short-circuit-proof: yes No-load proof: yes Output power: 90 W 150 W Maximum no-load power dissipation: < 0.6 W (230 V AC) < 0.6 W (120VAC) Power loss nominal load max.: < 8.1 W (120VAC) < 7.1 W (230 V AC) Crest factor: typ. 1.57 (120VAC) typ. 1.67 (230 V AC) Rise time: 50 ms (UOut=10%...90%) Connection in parallel: yes, for redundancy and increased capacity Connection in series: yes Signal (configurable) Digital: 0 VDC 12 VDC 24 mA Default: 12 VDC 24 mA 12VDC for UOut >0.9xUSet
|
Connection data | Input Connection method: Push-in connection Conductor cross section, rigid min.: 0.2 mm² Conductor cross section, rigid max.: 2.5 mm² Conductor cross section flexible min.: 0.2 mm² Conductor cross section flexible max.: 2.5 mm² Single conductor/terminal point, stranded, with ferrule, min.: 0.25 mm² Single conductor/terminal point, stranded, with ferrule, max.: 2.5 mm² Conductor cross section AWG min.: 24 Conductor cross section AWG max.: 14 Stripping length: 10 mm Output Connection method: Push-in connection Conductor cross section, rigid min.: 0.2 mm² Conductor cross section, rigid max.: 2.5 mm² Conductor cross section flexible min.: 0.2 mm² Conductor cross section flexible max.: 2.5 mm² Single conductor/terminal point, stranded, with ferrule, min.: 0.25 mm² Single conductor/terminal point, stranded, with ferrule, max.: 2.5 mm² Conductor cross section AWG min.: 24 Conductor cross section AWG max.: 14 Stripping length: 10 mm Signal Connection method: Push-in connection Conductor cross section, rigid min.: 0.2 mm² Conductor cross section, rigid max.: 2.5 mm² Conductor cross section flexible min.: 0.2 mm² Conductor cross section flexible max.: 2.5 mm² Single conductor/terminal point, stranded, with ferrule, min.: 0.25 mm² Single conductor/terminal point, stranded, with ferrule, max.: 2.5 mm² Conductor cross section AWG min.: 24 Conductor cross section AWG max.: 14 Stripping length: 10 mm
|
Signaling | Types of signaling: LED Signal output POut: > PThr (LED lights up yellow, output power > PThr, depending on the rotary selector switch setting) UOut: > 0.9xUSet (LED lights up green) < 0.9xUSet (LED flashes green)
|
Electrical properties | Number of phases: 1.00 Insulation voltage input/output: 4 kV AC (type test) 3 kV AC (routine test) Switching frequency: 4 kHz ... 70 kHz (Auxiliary converter stage) 80 kHz ... 190 kHz (Main converter stage) 30 kHz ... 150 kHz (PFC stage)
|
Product properties | Product type: Power supply Product family: QUINT POWER MTBF (IEC 61709, SN 29500): > 1221000 h (25°C) > 671000 h (40°C) > 248000 h (60°C) Insulation characteristics Protection class: II Degree of pollution: 2 Life expectancy (electrolytic capacitors) Current: 7.5 A Temperature: 40°C Time: 96000 h Additional text: 120VAC Life expectancy (electrolytic capacitors)â Current: 7.5 A Temperature: 40°C Time: 145000 h Additional text: 230VAC Life expectancy (electrolytic capacitors)ââ Current: 7.5 A Temperature: 25°C Time: 280000 h Additional text: 120VAC Life expectancy (electrolytic capacitors)âââ Current: 7.5 A Temperature: 25°C Time: 430000 h Additional text: 230VAC
|
Dimensions | Width: 45 mm Height: 106 mm Depth: 90 mm Installation dimensions Installation distance right/left (active): 15 mm / 15 mm (POutâ¥50%) Installation distance right/left (passive): 5 mm / 5 mm (POutâ¥50%) Installation distance right/left (active, passive): 0 mm / 0 mm (POutâ¤50%) Installation distance top/bottom (active): 30 mm / 30 mm (POutâ¥50%) Installation distance top/bottom (passive): 30 mm / 30 mm (POutâ¥50%) Installation distance top/bottom (active, passive): 30 mm / 30 mm (POutâ¤50%)
|
Mounting | Mounting type: DIN rail mounting With protective coating: No
|
Material specifications | Flammability rating according to UL94 (housing / terminal blocks): V0 Housing material: Plastic Type of housing: Polycarbonate Hood version: Polycarbonate
|
Environmental and real-life conditions | Ambient conditions Degree of protection: IP20 Ambient temperature (operation): -25°C ... 70°C (>60°C Derating: 2,5%/K) Ambient temperature (storage/transport): -40°C ... 85°C Ambient temperature (start-up type tested): -40°C Maximum altitude: ⤠5000 m (> 2000 m, observe derating) Climatic class: 3K3 (in acc. with EN 60721) Max. permissible relative humidity (operation): ⤠95 % (at 25°C, non-condensing) Shock: 18 ms, 30g, in each space direction (according to IEC 60068-2-27) Vibration (operation): < 15Hz, ±2.5mm amplitude; 15Hz ... 100Hz: 2.3g 90Min. (in accordance with IEC 60068-2-6)
|
Standards and regulations | Standard â Limitation of mains harmonic currents: EN61000-3-2 Standard â Safety extra-low voltage: IEC 61010-1 (SELV) IEC 61010-2-201 (PELV) Standard - Safe isolation: IEC 61558-2-16 IEC 61010-2-201 Standard - safety for equipment for measurement, control, and laboratory use: IEC 61010-1 IEC 61010-2-201(SELV) Standard - Safety of transformers: EN61558-2-16 Overvoltage category EN 61010-1: II(â¤5000m) EN 62477-1: III(â¤2000m)
|
Approvals | SIQ: CB-Scheme (IEC 61010-1, IEC 61010-2-201) UL approvals: UL Listed UL61010-1 UL Listed UL61010-2-201 ANSI/UL121201 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
|
EMC data | EMC requirements for noise emission: EN61000-6-3 EN61000-6-4 EMC requirements for noise immunity: EN61000-6-1 EN61000-6-2 Electromagnetic compatibility: Conformance with EMC Directive 2014/30/EU EMC requirements, power plant: IEC 61850-3 EN61000-6-5 Conducted noise emission: EN55016 EN61000-6-3 (Class B) Noise emission: Additional basic standard EN 61000-6-5 (immunity in power station), IEC/EN 61850-3 (energy supply) EN55016 EN61000-6-3 (Class B) Harmonic currents Standards/regulations: EN61000-3-2 EN61000-3-2 (Class A) Frequency range: 0 kHz ... 2 kHz Flicker Standards/regulations: EN61000-3-3 Frequency range: 0 kHz ... 2 kHz Electrostatic discharge Standards/regulations: EN61000-4-2 Electrostatic dischargeâ Contact discharge: 8 kV (Test Level 4) Discharge in air: 15 kV (Test Level 4) Comments: Criterion A Electromagnetic HF field Standards/regulations: EN61000-4-3 Electromagnetic HF fieldâ Frequency range: 80 MHz ... 1 GHz 1 GHz ... 6 GHz Test field strength: 20 V/m (Test Level 3) 10 V/m (Test Level 3) Comments: Criterion A Fast transients (burst) Standards/regulations: EN61000-4-4 Fast transients (burst)â Input: 4 kV (Test Level 4 - asymmetrical) Output: 4 kV (Test Level 4 - asymmetrical) Signal: 4 kV (Test Level 4 - asymmetrical) Comments: Criterion A Surge voltage load (surge) Standards/regulations: EN61000-4-5 Input: 2 kV (Test Level 4 - symmetrical) 4 kV (Test Level 4 - asymmetrical) Output: 1 kV (Test Level 3 - symmetrical) 2 kV (Test Level 3 - asymmetrical) Signal: 0.5 kV (Test Level 2 - symmetrical) 1 kV (Test Level 2 - asymmetrical) Comments: Criterion A Conducted interference Standards/regulations: EN61000-4-6 Conducted interferenceâ I/O/S: asymmetrical Frequency range: 0.15 MHz ... 80 MHz Comments: Criterion A Voltage: 10 V (Test Level 3) Power frequency magnetic field Standards/regulations: EN61000-4-8 Frequency: 16.67 Hz 50 Hz 60 Hz 50 Hz 60 Hz 0 Hz Test field strength: 100 A/m 1 kA/m 300 A/m Additional text: 60 s 3 s DC, 60s Comments: Criterion A Frequency range: 50 Hz ... 60 Hz Voltage dips Standards/regulations: EN61000-4-11 Voltage: 100 VAC Frequency: 60 Hz Voltage dip: 70 % 40 % 0 % Number of periods: 0.5 / 1 / 30 periods 5 / 10 / 50 periods 0.5 / 1 / 5 / 50 periods Additional text: Test Level 2 Comments: Criterion A Criterion B Criterion B Pulse-shape magnetic field Standards/regulations: EN61000-4-9 Test field strength: 1000 A/m Comments: Criterion A Attenuated sinusoidal oscillations (ring wave) Standards/regulations: EN61000-4-12 Input: 2 kV (symmetrical) 4 kV (asymmetrical) Comments: Criterion A Asymmetrical conducted disturbance variables Standards/regulations: EN61000-4-16 Test level 1: 16.67 Hz 50 Hz 60 Hz 150 Hz 180 Hz (Test Level 3) Voltage: 30 V (10s) 300 V (1 s) Test level 2: 16.67 Hz 50 Hz 60 Hz (Test Level 2) Comments: Criterion A Attenuated oscillating wave Standards/regulations: EN61000-4-18 Voltage: 1 kV (symmetrical) 2.5 kV (asymmetrical) 1 kV (symmetrical) Comments: Criterion A Criteria Criterion A: Normal operating behavior within the specified limits. Criterion B: Temporary impairment to operational behavior that is corrected by the device itself. Criterion C: Temporary adverse effects on the operating behavior, which the device corrects automatically or which can be restored by actuating the operating elements.
|