PHOENIX CONTACT 2909513
PHOENIX CONTACT 2909513
PHOENIX CONTACT 2909513
PHOENIX CONTACTNon disponibile

PLC-RPT-12DC/21-21/EX - Relay Module

PLC-INTERFACE, consisting of DIN-rail-mountable basic terminal block in 14 mm with Push-in connection and plug-in relay with power contact, 2 changeover contacts, 12 V DC input voltage. Approved according to ATEX/IECEx (Zone 2) and Ex Zone Class I, Div. 2.
Cod. Articolo: 2909513
Cod. Fornitore: 2909513
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Relay Module
Product family: PLC-INTERFACE
Application: Class I, Division 2
potentially explosive areas
Operating mode: 100% operating factor
Mechanical service life: 3x 107 cycles
Insulation characteristics
Insulation: Safe isolation, reinforced insulation
Insulation characteristics: Standards/regulations
Insulation: Safe isolation, reinforced insulation
Overvoltage category: III
Pollution degree: 3
Electrical propertiesMaximum power dissipation for nominal condition: 0.4 W
Test voltage (Winding/contact): 4 kV AC (50Hz, 1min., winding/contact)
Test voltage (Changeover contact/changeover contact): 2.5 kV AC (50Hz, 1min., changeover contact/changeover contact)
Standards/regulations
Rated insulation voltage: 250 VAC
Rated surge voltage: 6 kV
Input dataCoil side
Nominal input voltage UN: 12 VDC
Input voltage range: 10.3 VDC ... 16.8 VDC (20°C)
Drive and function: monostable
Drive (polarity): polarized
Typical input current at UN: 33 mA
Typical response time: 8 ms
Typical release time: 10 ms
Protective circuit: Reverse polarity protection; Polarity protection diode
Surge protection; Freewheeling diode
Operating voltage display: Yellow LED
Output dataSwitching
Contact switching type: 2 changeover contacts
Type of switch contact: Single contact
Contact material: AgNi
Maximum switching voltage: 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage: 5 V AC/DC (10mA)
Limiting continuous current: 6 A
Maximum inrush current: 15 A (300ms)
Min. switching current: 10 mA (5V)
Interrupting rating (ohmic load) max.: 140 W (at 24 V DC)
85 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
60 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity: 2 A (at 24 V, DC13)
0.2 A (at 250 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 250 V, AC15)
Connection dataConnection method: Push-in connection
Stripping length: 10 mm
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
DimensionsWidth: 14 mm
Height: 80 mm
Depth: 94 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Degree of protection (Relay): RT III (Relay)
Degree of protection (Relay base): IP20 (Relay base)
Ambient temperature (operation): -20°C ... 60°C (UL)
-40°C ... 60°C (ATEX / IECEx)
Ambient temperature (storage/transport): -40°C ... 85°C
ApprovalsCE
Certificate: CE-compliant
ATEX
Identification:  II 3G Ex ec nC IIC T4 Gc
Certificate: IBExU16ATEXB015 X
IECEx
Identification: Ex ec nC IIC T4 Gc
Certificate: IECEx IBE 16.0029X
UKCAEx(UKEX)
Identification:  II 3 G Ex ec nC IIC T4 Gc
Certificate: PxCIF21UKEX2909514X
UL, USA
Identification: Class I, Zone 2, AEx nA nC IIC T6
UL, USA/Canada
Identification: Class I, Div. 2, Groups A, B, C, D
UL, Canada
Identification: Class I, Zone 2, Ex nA nC IIC Gc T6 X
Shipbuilding approval
Certificate: TAE0000196
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
EN60068-2-60
DNV GL data
Temperature: D
Humidity: A
Vibration: B/C
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Electromagnetic compatibility: Conformance with EMC directive
Standards and regulationsStandards/regulations
Standards/regulations: IEC 60947-5-1
EN60079-0
EN60079-7
EN60079-15
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Specifiche
ECLASSECLASS-11.0: 27371601
ECLASS-12.0: 27371601
ECLASS-13.0: 27371601
ETIMETIM 9.0: EC001437
UNSPSCUNSPSC 21.0: 39122300
Descrizione
PLC-INTERFACE, consisting of DIN-rail-mountable basic terminal block in 14 mm with Push-in connection and plug-in relay with power contact, 2 changeover contacts, 12 V DC input voltage. Approved according to ATEX/IECEx (Zone 2) and Ex Zone Class I, Div. 2.
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_00056.pdf

Approvals_00057.pdf

Approvals_00240.pdf

Approvals_01309.pdf

Approvals_01310.pdf

Approvals_01883.pdf

Approvals_01884.pdf

Approvals_01925.pdf

Certification_00261.pdf

Manufacturer_declaration_03362.pdf

Manufacturer_declaration_03364.pdf

Manufacturer_declaration_16395.pdf

Package_slip_01754.pdf

Product_information_00033.pdf

Product_information_00738.pdf

Technical_drawing_40756.pdf