Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 2909847
PHOENIX CONTACT 2909847
PHOENIX CONTACTNon disponibile

RIF-2-RSC-LV-230AC/4X21/EX - Relay Module

Pre-assembled relay module consisting of: relay base, function plug-in module, power contact relay, and retaining bracket, approval in accordance with ATEX/IECEx (Zone 2) and Ex Zone Class I, Div. 2, Screw connection, 4 changeover contacts, Varistor, Input voltage: 230 VAC
Cod. Articolo: 2909847
Cod. Fornitore: 2909847
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Relay Module
Product family: RIFLINEcomplete
Application: Class I, Division 2
potentially explosive areas
Operating mode: 100% operating factor
Mechanical service life: approx. 2x 107 cycles
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics​
Insulation: Basic insulation
Overvoltage category: III
II (Zone 2)
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 1.9 W
Test voltage (Winding/contact): 2.5 kVrms (50Hz, 1min., winding/contact)
Test voltage (Contact/contact): 2 kVrms (50Hz, 1min., contact/contact)
Rated insulation voltage: 250 VAC
Rated surge voltage: 2.5 kV
Input dataCoil side
Nominal input voltage UN: 230 VAC
Input voltage range: 184 VAC ... 276 VAC (20°C)
Input voltage range in reference to UN: see diagram
Mains frequency: 50/60 Hz
Drive and function: monostable
Drive (polarity): polarized
Typical input current at UN: 6.5 mA
Typical response time: 5 ms ... 15 ms
Typical release time range: 5 ms ... 20 ms
Coil voltage: 230 VAC
Protective circuit: Varistor
Operating voltage display: Yellow LED
Output dataSwitching
Contact switching type: 4 changeover contacts
Type of switch contact: Single contact
Contact material: AgNi
Maximum switching voltage: 250 V AC/DC
Minimum switching voltage: 5 V (24mA)
Limiting continuous current: 5 A (see diagram)
Maximum inrush current: 16 A (20 ms, N/O contacts)
Min. switching current: 5 mA (24V)
Interrupting rating (ohmic load) max.: 120 W (24VDC)
124 W (48VDC)
108 W (60VDC)
52 W (110VDC)
48 W (220VDC)
1250 VA (250VAC)
Utilization category CB Scheme (IEC 60947-5-1): AC15, 1 A/240 V (N/O contact)
DC13, 2 A/24 V (N/O contact)
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Conductor cross section rigid: 0.5 mm² ... 4 mm²
Conductor cross-section rigid (2 conductors with same cross section): 0.5 mm² ... 2.5 mm²
Conductor cross section flexible: 0.5 mm² ... 4 mm²
0.5 mm² ... 4 mm² (Ferrule with plastic sleeve)
Conductor cross section flexible (2 conductors with same cross section): 0.5 mm² ... 2.5 mm²
0.5 mm² ... 1.5 mm² (TWIN ferrule with plastic sleeve)
Conductor cross section AWG: 20 ... 10 (solid)
20 ... 12 (flexible)
Tightening torque: 0.5 Nm ... 0.6 Nm
DimensionsWidth: 27 mm
Height: 89 mm
Depth: 75 mm
Material specificationsFlammability rating according to UL 94: V2 (Housing)
Environmental and real-life conditionsAmbient conditions
Degree of protection (Relay base): IP20 (Relay base)
Degree of protection (Relay): RT III (Relay)
Ambient temperature (operation): -40°C ... 50°C
Ambient temperature (storage/transport): -40°C ... 85°C
ApprovalsATEX
Identification:  II 3G Ex ec nC IIC T4 Gc
Certificate: IBExU17ATEXB014X
UKCAEx(UKEX)
Identification:  II 3G Ex ec nC IIC T4 Gc
Certificate: PxcIF21UKEX2909741X
IECEx
Identification: Ex ec nC IIC T4 Gc
Certificate: IECEx IBE 17.0032X
UL, USA/Canada
Identification: Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
EN60068-2-60
Standards and regulationsStandards/regulations: IEC 60947-5-1
Ex zone
Standards/regulations: EN/IEC 60079-0
EN/IEC 60079-7
EN/IEC 60079-15
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Specifiche
ECLASSECLASS-11.0: 27371601
ECLASS-12.0: 27371601
ECLASS-13.0: 27371601
ETIMETIM 9.0: EC001437
UNSPSCUNSPSC 21.0: 39122300
Descrizione
Pre-assembled relay module consisting of: relay base, function plug-in module, power contact relay, and retaining bracket, approval in accordance with ATEX/IECEx (Zone 2) and Ex Zone Class I, Div. 2, Screw connection, 4 PDTs, Input voltage: 230 V AC
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_01328.pdf

Approvals_01329.pdf

Approvals_01331.pdf

Approvals_01332.pdf

Manufacturer_declaration_01083.pdf

Manufacturer_declaration_03135.pdf

Manufacturer_declaration_16476.pdf

Package_slip_02195.pdf

Technical_drawing_40865.pdf