PHOENIX CONTACT 2910517
PHOENIX CONTACT 2910517
PHOENIX CONTACTNon disponibile

PLC-RSC-120UC/21HC/MS - Relay Module

PLC-INTERFACE, consisting of a relay base and pluggable power contact relay with manual operation, integrated status LED, Screw connection, 1changeover contact, Bridge rectifier, Input voltage: 120 VAC / 110 VDC
Cod. Articolo: 2910517
Cod. Fornitore: 2910517
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
Product propertiesProduct type: Relay Module
Product family: PLC-INTERFACE
Application: Palm switch
High continuous currents
Operating mode: 100% operating factor
Mechanical service life: 5x 106 cycles
Insulation characteristics
Insulation: Safe isolation, reinforced insulation
Insulation characteristics​
Insulation: Safe isolation, reinforced insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.6 W
Test voltage (Winding/contact): 4 kVrms (50Hz, 1min., winding/contact)
Test voltage (Changeover contact/changeover contact): 2.5 kVrms (50Hz, 1min., changeover contact/changeover contact)
Rated insulation voltage: 250 VAC
Rated surge voltage: 6 kV
Input dataCoil side
Nominal input voltage UN: 120 VAC
110 VDC
Input voltage range: 96 VAC ... 168 VAC (20°C)
93.5 VDC ... 154 VDC (20°C)
Drive and function: monostable
Drive (polarity): polarized
Typical input current at UN: 5 mA
Typical response time: 6 ms (110VDC)
3 ms ... 15 ms (120VAC)
Typical release time: 8 ms (110VDC)
Typical release time range: 3 ms ... 15 ms (120VAC)
Protective circuit: Bridge rectifier; Bridge rectifier
Operating voltage display: Yellow LED
Output dataSwitching
Contact switching type: 1changeover contact
Type of switch contact: Single contact
Contact material: AgNi
Maximum switching voltage: 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage: 12 V (10mA)
Limiting continuous current: 10 A
Maximum inrush current: 24 A (20ms)
Min. switching current: 10 mA (12V)
Interrupting rating (ohmic load) max.: 264 W (24VDC)
62 W (48VDC)
48 W (60VDC)
52 W (110VDC)
66 W (220VDC)
2750 VA (250VAC)
Switching capacity: 2 A (24V, DC13)
3 A (230 V, AC15)
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
Tightening torque: 0.6 Nm ... 0.8 Nm
DimensionsWidth: 14 mm
Height: 80 mm
Depth: 104 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Degree of protection (Relay): RT II (Relay)
Degree of protection (Relay base): IP20 (Relay base)
Degree of protection (Installation location): ≥ IP54 (Installation location)
Ambient temperature (operation): -40°C ... 55°C
Ambient temperature (storage/transport): -20°C ... 85°C
Altitude: ≤ 2000 m
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
Shipbuilding approval
Certificate: TAE0000196
UL, USA
Identification: UL508
UL508 Recognized
UL, USA/Canada
Identification: UL508
UL508 Recognized
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
EN60068-2-60
DNV GL data
Temperature: D
Humidity: A
Vibration: B/C
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Electromagnetic compatibility: Conformance with EMC directive
Standards and regulationsStandards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Specifiche
ECLASSECLASS-11.0: 27371601
ECLASS-12.0: 27371601
ECLASS-13.0: 27371601
ETIMETIM 9.0: EC001437
UNSPSCUNSPSC 21.0: 39122300
Descrizione
PLC-INTERFACE, consisting of a relay base and pluggable power contact relay with manual operation, integrated status LED, Screw connection, 1 PDT, Input voltage: 120 V AC / 110 V DC
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_00240.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Approvals_01883.pdf

Manufacturer_declaration_03396.pdf

Manufacturer_declaration_03397.pdf

Manufacturer_declaration_16527.pdf

Package_slip_01759.pdf

Product_information_00033.pdf

Product_information_00756.pdf

Technical_drawing_40988.pdf