PLC-RSC- 24UC/2X21/FG - Relay Module

PLC-INTERFACE, consisting of a relay base and plug-in safety relay with force-guided contacts in accordance with DINEN61810-3, Screw connection, 2 changeover contacts, forcibly actuated, Bridge rectifier, Input voltage: 24 V AC/DC
Cod. Articolo: 2910536
Cod. Fornitore: 2910536
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Relay Module
Product family: PLC-INTERFACE
Application: Forcibly guided contacts
Operating mode: 100% operating factor
Mechanical service life: approx. 107 cycles
B10d: 600000 Cycles (AC1; 250V/6A; 1 NO)
900000 Cycles (AC1; 250V/3A; 1NO)
1800000 Cycles (AC1; 250V/1,5A; 1NO)
180000 Cycles (AC15; 250V/3A; 1NO)
560000 Cycles (AC15; 250V/2A; 1NO)
4600000 Cycles (AC15; 250V/0,75A; 1NO)
360000 Cycles (DC13; 24V/3A; 1NO)
740000 Cycles (DC13; 24V/1,5A; 1NO)
4200000 Cycles (DC13; 24V/0,75A; 1NO)
Insulation characteristics
Insulation: Safe isolation, reinforced insulation
Insulation characteristics: Standards/regulations
Insulation: Safe isolation, reinforced insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.72 W
Test voltage (Winding/contact): 4 kVrms (50Hz, 1min., winding/contact)
Test voltage (Changeover contact/changeover contact): 2.5 kVrms (50Hz, 1min., changeover contact/changeover contact)
Standards/regulations
Rated insulation voltage: 250 VAC
Rated surge voltage: 6 kV
Input dataCoil side
Nominal input voltage UN: 24 V AC/DC
Input voltage range: 20.9 V AC/DC ... 32.4 V AC/DC (20°C)
Input voltage range in reference to UN: see diagram
Drive and function: monostable
Drive (polarity): polarized
Typical input current at UN: 30 mA
Typical response time: 3 ms ... 15 ms
Typical release time range: 3 ms ... 15 ms
Coil voltage: 24 VDC
Protective circuit: Bridge rectifier
Operating voltage display: Yellow LED
Output dataSwitching
Contact switching type: 2 changeover contacts, forcibly actuated
Type of switch contact: Single contact
Contact material: AgNi
Maximum switching voltage: 250 V AC/DC
Minimum switching voltage: 5 V (10mA)
Limiting continuous current: 6 A
Maximum inrush current: 6 A
Min. switching current: 10 mA (5 V)
Interrupting rating (ohmic load) max.: 144 W (24VDC)
288 W (48VDC)
88 W (110VDC)
110 W (220VDC)
1500 VA (250VAC)
Switching capacity min.: 150 mW
Switching capacity: 3 A (24V, DC13)
3 A (230 V, AC15)
Force-guided contacts in accordance with EN61810-3: Type B
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
Tightening torque: 0.6 Nm ... 0.8 Nm
DimensionsWidth: 14 mm
Height: 80 mm
Depth: 104 mm
Environmental and real-life conditionsAmbient conditions
Degree of protection (Relay): RT II (Relay)
Degree of protection (Relay base): IP20 (Relay base)
Degree of protection (Installation location): ≥ IP54 (Installation location)
Ambient temperature (operation): -20°C ... 60°C
Ambient temperature (storage/transport): -20°C ... 85°C
Altitude: ≤ 2000 m
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
UL, USA
Identification: UL508
UL508 Recognized
UL, USA/Canada
Identification: UL508
UL508 Recognized
Shipbuilding approval
Certificate: TAE0000196
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
EN60068-2-60
DNV GL data
Temperature: D
Humidity: A
Vibration: B/C
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Electromagnetic compatibility: Conformance with EMC directive
Standards and regulationsStandards/regulations
Standards/regulations: IEC 60947-5-1
DINEN61810-3
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Specifiche
ECLASSECLASS-11.0: 27371601
ECLASS-12.0: 27371601
ECLASS-13.0: 27371601
ETIMETIM 9.0: EC001437
UNSPSCUNSPSC 21.0: 39122300
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Approvals_00240.pdf

Approvals_01883.pdf

Manufacturer_declaration_03436.pdf

Manufacturer_declaration_03437.pdf

Manufacturer_declaration_03602.pdf

Manufacturer_declaration_16543.pdf

Package_slip_01758.pdf

Product_information_00033.pdf

Product_information_00756.pdf

Technical_drawing_41004.pdf