Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 2941468
PHOENIX CONTACTNon disponibile

EMG 17-REL/KSR-W230/21-21-LCAU - Relay Module

Relay module, with soldered-in miniature switching relay, contact (AgNi+Au): small to large loads, 2 changeover contacts, input voltage 230 V AC
Cod. Articolo: 2941468
Cod. Fornitore: 2941468
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
NotesGeneral: Only available as AC voltage version.
Utilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Relay Module
Product family: EMG
Application: Universal
Operating mode: 100% operating factor
Mechanical service life: approx. 5x 107 cycles
Insulation characteristics
Insulation: Basic insulation
Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths
Insulation characteristics: Air clearances and creepage distances between the power circuits
Insulation: Basic insulation
Safe isolation, reinforced insulation, and 6 kV between input circuit and output contact current paths
Overvoltage category: II
Pollution degree: 2
Insulation characteristics: Air clearances and creepage distances between input and contact circuit (or output contact current path)
Insulation: Safe isolation, reinforced insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesMaximum power dissipation for nominal condition: 0.92 W
Test voltage (Winding/contact): 4 kV AC (50Hz, 1min., winding/contact)
Test voltage (Contact/contact): 1 kV AC (50Hz, 1min., changeover contact/changeover contact)
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 260 VAC
Rated surge voltage: 2.3 kV
Air clearances and creepage distances between input and contact circuit (or output contact current path)
Rated insulation voltage: 260 VAC
Rated surge voltage: 6 kV
Input dataCoil side
Nominal input voltage UN: 230 VAC
Input voltage range: 184 VAC ... 253 VAC (20°C)
Mains frequency: 50/60 Hz
Drive and function: monostable
Drive (polarity): polarized
Typical input current at UN: 4 mA
Typical response time: 7 ms
3 ms ... 12 ms
Typical release time: 3 ms
Typical release time range: 2 ms ... 9 ms
Operating voltage display: Glow lamp
Output dataSwitching
Contact switching type: 2 changeover contacts
Type of switch contact: Single contact
Contact material: AgNi, hard gold-plated
Maximum switching voltage: 30 VAC
36 VDC
Limiting continuous current: 50 mA
Maximum inrush current: 0.2 A
Interrupting rating (ohmic load) max.: 1.2 W (at 24 V DC)
Switching: when the gold layer is destroyed
Note: the following values are applicable if a gold layer is destroyed
Maximum switching voltage: 250 V AC/DC
Limiting continuous current: 5 A
Maximum inrush current: 6 A
Interrupting rating (ohmic load) max.: 120 W (at 24 V DC)
95 W (at 48 V DC)
60 W (at 60 V DC)
40 W (at 110 V DC)
55 W (at 220 V DC)
1250 VA (for 250 V AC)
Connection dataCoil side
Connection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 4 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12
Contact side
Connection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 4 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 12
DimensionsWidth: 17.5 mm
Height: 75 mm
Depth: 62.5 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -20°C ... 40°C
Ambient temperature (storage/transport): -20°C ... 70°C
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: IEC 60664-1
Air clearances and creepage distances between input and contact circuit (or output contact current path)
Standards/regulations: IEC 60664-1
Standards/regulations
Standards/regulations: EN61810-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Specifiche
ECLASSECLASS-11.0: 27371601
ECLASS-12.0: 27371601
ECLASS-13.0: 27371601
ETIMETIM 9.0: EC001437
UNSPSCUNSPSC 21.0: 39122300
Descrizione
Relay module, with soldered-in miniature switching relay, contact (AgNi+Au): Small to large loads, 2 PDT, 230 V AC input voltage
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00002.pdf

Application_note_00006.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Manufacturer_declaration_00975.pdf

Manufacturer_declaration_01706.pdf

Manufacturer_declaration_03515.pdf

Manufacturer_declaration_03516.pdf

Manufacturer_declaration_16701.pdf

Technical_drawing_41230.pdf