Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 2963941
PHOENIX CONTACTNon disponibile

PSR-SPP- 24UC/ESA4/3X1/1X2/B - Safety relays

Safety relay for emergency stop and safety door monitoring up to SIL3 or Cat.4, PLe in accordance with ENISO13849, 2-channel operation, 3enabling current paths, nominal input voltage: 24VDC, pluggable Push-in terminal block
Cod. Articolo: 2963941
Cod. Fornitore: 2963941
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Safety relays
Product family: PSRclassic
Application: Emergency stop
Safety door
Mechanical service life: approx. 107 cycles
Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN61810-3
Electrical propertiesMaximum power dissipation for nominal condition: 16.44 W (US=26.4V, IL²=72A², PTotalmax=2.04W+14.4W)
Nominal operating mode: 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 V
Rated surge voltage/insulation: See section “Insulation coordination”
Input dataGeneral
Rated control circuit supply voltage US: 24 VDC -15% / +10%
Power consumption at US: typ. 1.68 W (DC)
Rated control supply current IS: typ. 70 mA
Input voltage range in reference to UN: 0.85 ... 1.1
Typical input current at UN: 70 mA DC (at US)
Inrush current: < 3.5 A (Δt=3ms at Us)
< 100 mA (Δt=500ms, with Us/Ix at S12)
> -100 mA (Δt=300ms, with Us/Ix at S22)
< 6 mA (with Us/Ix to S34)
Current consumption: typ. 38 mA (S12)
typ. -38 mA (S22)
typ. 1 mA (with Us/Ix to S34)
Voltage at input/start and feedback circuit: approx. 24 VDC
Filter time: 5 ms (at A1 in the event of voltage dips at Us)
No test pulses permitted
Typical response time: 150 ms (automatic start)
Typ. starting time with Us: 250 ms (with Us when controlled via A1)
Typical release time: 20 ms (on demand via the sensor circuit)
45 ms (on demand via A1)
Concurrence: ∞
Recovery time: 1 s (following demand of the safety function)
< 1 s (Boot time)
Protective circuit: Surge protection; Suppressor diode
Max. permissible overall conductor resistance: approx. 50 Ω (Input and start circuits at US)
Operating voltage display: Green LED
Status display: Green LED
Output dataContact switching type: 3 enabling current paths
1 signaling current path
Contact material: AgSnO2, + 0.2 µm Au
Maximum switching voltage: 250 VAC
Minimum switching voltage: 10 V AC/DC
Limiting continuous current: 6 A (N/O contact)
Maximum inrush current: 6 A
Inrush current, minimum: 10 mA
Sq. Total current: 72 A2 (Enabling current paths)
36 A2 (Signaling current path31/32)
Switching capacity min.: 100 mW
Switching capacity in accordance with IEC 60947-5-1: DC13, enabling current paths
AC15, enabling current paths
2 A (DC13, signaling current paths)
1.5 A (AC15, signaling current paths)
Output fuse: 10 A gL/gG (Enabling current paths)
4 A gL/gG (Low-demand enabling current paths)
6 A gL/gG (Signaling current path)
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross-section AWG: 24 ... 16
Stripping length: 8 mm
DimensionsWidth: 22.5 mm
Height: 112 mm
Depth: 114.5 mm
Material specificationsHousing material: Polyamide
CharacteristicsSafety data
Stop category: 0
Safety data: ENISO13849
Category: 4
Performance level (PL): e (5ADC13; 5AAC15; 8760switching cycles/year)
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL): 3
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL): 3
Safety data: ENIEC 62061
Safety Integrity Level (SIL): 3
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -20°C ... 55°C (observe derating)
Ambient temperature (storage/transport): -40°C ... 70°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
Shock: 15g
Vibration (operation): 10Hz...150Hz, 2g
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: DINEN60947-1
MountingMounting type: DIN rail mounting
Assembly instructions: See derating curve
Mounting position: vertical or horizontal
Connection method: Push-in connection
Specifiche
ECLASSECLASS-11.0: 27371819
ECLASS-13.0: 27371819
ECLASS-12.0: 27371819
ETIMETIM 9.0: EC001449
UNSPSCUNSPSC 21.0: 39122205
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_00175.pdf

Approvals_01217.pdf

Certification_00213.pdf

Certification_00328.pdf

Data_sheet_03959.pdf

Data_sheet_03960.pdf

Manufacturer_declaration_00507.pdf

Manufacturer_declaration_02169.pdf

Manufacturer_declaration_05474.pdf

Manufacturer_declaration_16846.pdf

Package_slip_01895.pdf

Package_slip_01896.pdf

Technical_drawing_41440.pdf