Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 2964678
PHOENIX CONTACTNon disponibile

DEK-OE-230AC/ 48DC/100/SO 46 - Solid-state relay terminal block

Solid-state relay interface designed to prevent interference on the control side, input: 230 V AC, output: 48 V DC/100 mA
Cod. Articolo: 2964678
Cod. Fornitore: 2964678
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
NotesGeneral: The housing is open on one side. The appropriate cover is D-DEK 1,5 GN (2716949).
Use of EB 80-DIK... bridges in the DEK terminal blocks: Absorption of humidity from the ambient air as well as an unfavorable tolerance between a larger number of DEK terminal blocks and the EB 80-DIK... bridge may cause (minor) expansion of the DEK housing. When the EB 80-DIK... bridges are used, therefore, it is recommended that these be disconnected after about 10 to 12 DEK terminal blocks and a wire bridge to the next DEK terminal block be inserted in their place.
Product propertiesProduct type: Solid-state relay module
Product family: DEK
Application: Filter to prevent interference
Operating mode: 100% operating factor
Insulation characteristics
Insulation: Basic insulation
Insulation characteristics​
Insulation: Basic insulation
Overvoltage category: III
Pollution degree: 2
Electrical propertiesTest voltage (Input/output): 2.5 kV AC (Input/output)
Input dataNominal input voltage UN: 230 VAC
Input voltage range in reference to UN: 0.9 ... 1.1
Input voltage range: 207 VAC ... 253 VAC
Switching threshold "0" signal, voltage: ≤ 92 VAC
Switching threshold "1" signal voltage: > 207 VAC
Typical input current at UN: 2.5 mA
Typical response time: 4.4 ms
Typical turn-off time: 14 ms
Operating voltage display: Yellow LED
Protective circuit: Surge protection; Varistor
RC element; RC element
Transmission frequency: 5 Hz
Output dataContact switching type: 1 N/O contact
Design of digital output: electronic
Output voltage range: 3 VDC ... 48 VDC
Limiting continuous current: 100 mA
Voltage drop at max. limiting continuous current: ≤ 0.9 V
Output circuit: 3-conductor, ground-referenced
Protective circuit: Reverse polarity protection; Polarity protection diode
Free running; Freewheeling diode
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross section AWG: 24 ... 14
Tightening torque: 0.5 Nm
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 56 mm
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): 0°C ... 50°C
Ambient temperature (storage/transport): 0°C ... 70°C
Standards and regulationsStandards/regulations: IEC 60947-5-1
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Specifiche
ECLASSECLASS-11.0: 27371604
ECLASS-12.0: 27371604
ECLASS-13.0: 27371604
ETIMETIM 9.0: EC001504
UNSPSCUNSPSC 21.0: 39122300
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Manufacturer_declaration_03578.pdf

Manufacturer_declaration_03579.pdf

Manufacturer_declaration_16877.pdf

Product_information_00033.pdf

Product_information_00768.pdf

Technical_drawing_41471.pdf