PHOENIX CONTACT 2980322
PHOENIX CONTACTNon disponibile

PLC-BSC-120UC/ 1/SEN/SO46 - Relay base

6.2 mm PLC basic terminal block with interference current and interference voltage protection on the control side, with screw connection, without relay or solid-state relay, with sensor supply voltage distribution (BB), 1 N/O contact, input voltage 120 V AC
Cod. Articolo: 2980322
Cod. Fornitore: 2980322
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
NotesUtilization restriction
EMC note: EMC: class A product, see manufacturer's declaration in the download area
Product propertiesProduct type: Relay socket
Product family: PLC-INTERFACE
Application: Filter to prevent interference
Operating mode: 100% operating factor
Compatible components: Miniature relay, REL-MR-60DC/21AU, REL-MR-60DC/21; miniature optocoupler, OPT-60DC/48DC/100, OPT-60DC/24DC/2, OPT-60DC/230AC/1
Insulation characteristics
Pollution degree: 3
Electrical propertiesProtective circuit: Bridge rectifier; Bridge rectifier
RCZ filter; RCZ filter
Input dataNominal input voltage UN: 120 VAC
110 VDC
Input voltage range in reference to UN: 0.85 ... 1.1
Relay assembly
Nominal input voltage UN: 120 VAC
110 VDC
Input voltage range in reference to UN: 0.8 ... 1.4
Typical input current at UN: 7 mA (50Hz)
8 mA (60Hz)
Typical response time: 7 ms
Typical release time: 20 ms
Typical release voltage: 50 VAC
Operating voltage display: Yellow LED
Protective circuit: Bridge rectifier; Bridge rectifier
Filter; Filter
Optocoupler assembly
Nominal input voltage UN: 120 VAC
110 VDC
Input voltage range in reference to UN: 0.85 ... 1.1
Typical input current at UN: 7 mA
8 mA
Switching threshold "0" signal in reference to UN: ≤ 0.4
Typical response time: 6 ms
Typical release time: 10 ms
Operating voltage display: Yellow LED
Protective circuit: Bridge rectifier; Bridge rectifier
Filter; Filter
Output dataCompatible components: Miniature relay, REL-MR-60DC/21AU, REL-MR-60DC/21; miniature optocoupler, OPT-60DC/48DC/100, OPT-60DC/24DC/2, OPT-60DC/230AC/1
Maximum switching voltage: 48 VDC
30 VDC
253 VAC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage: 3 VDC
24 VAC
Limiting continuous current: 100 mA
3 A
0.75 A
Voltage drop at max. limiting continuous current: < 1 V
< 200 mV
< 1 V
Output circuit: 2-conductor, floating
Protective circuit: Reverse polarity protection
Surge protection
Reverse polarity protection
Surge protection
RCV circuit
Maximum inrush current: 15 A (10 ms)
30 A (10 ms)
Leakage current: < 1 mA
Phase angle cos phi min: 0.5
Max. load value: 4.5 A2s
Connection dataConnection method: Screw connection
Stripping length: 8 mm
Screw thread: M3
Conductor cross section rigid: 0.14 mm² ... 2.5 mm²
Conductor cross section flexible: 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG: 26 ... 14
Tightening torque: 0.45 Nm ... 0.55 Nm (Usually these terminal blocks must be supported during conductor connection (held by one hand, supported on the housing))
SignalingStatus display: LED
DimensionsWidth: 6.2 mm
Height: 80 mm
Depth: 94 mm
Material specificationsFlammability rating according to UL 94: V0 (Housing)
Environmental and real-life conditionsAmbient conditions
Ambient temperature (operation): -40°C ... 55°C
Ambient temperature (storage/transport): -40°C ... 85°C
ApprovalsCE
Certificate: CE-compliant
UKCA
Certificate: UKCA-compliant
Shipbuilding approval
Certificate: TAE0000196
Corrosive gas test
Identification: ISA-S71.04. G3 Harsh Group
EN60068-2-60
DNV GL data
Temperature: D
Humidity: A
Vibration: B/C
EMC: B
Enclosure: Required protection according to the Rules shall be provided upon installation on board
EMC dataLow Voltage Directive: Conformance with Low Voltage Directive
Electromagnetic compatibility: Conformance with EMC directive
MountingMounting type: DIN rail mounting
Assembly instructions: in rows with zero spacing
Mounting position: any
Specifiche
ECLASSECLASS-11.0: 27371603
ECLASS-12.0: 27371603
ECLASS-13.0: 27371603
ETIMETIM 9.0: EC001456
UNSPSCUNSPSC 21.0: 39122300
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00006.pdf

Application_note_00148.pdf

Approvals_00240.pdf

Approvals_01560.pdf

Approvals_01561.pdf

Manufacturer_declaration_03373.pdf

Manufacturer_declaration_03374.pdf

Manufacturer_declaration_03684.pdf

Manufacturer_declaration_16993.pdf

Package_slip_01741.pdf

Product_information_00033.pdf

Product_information_00531.pdf

Technical_drawing_41634.pdf