Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 2981431
PHOENIX CONTACT 2981431
PHOENIX CONTACTNon disponibile

PSR-SPP-24DC/ESD/5X1/1X2/300 - Safety relays

Safety relay for emergency stop and safety door monitoring up to SIL3 or Cat.4, PLe (ENISO13849), one- or two-channel operation, automatic or manual activation, 3N/O contacts, 1N/C contact, 2N/O contacts with dropout delay of 0.2s ... 300s, pluggable Push-in terminal block
Cod. Articolo: 2981431
Cod. Fornitore: 2981431
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Descrizione
Download
Caratteristiche Tecniche
Product propertiesProduct type: Safety relays
Product family: PSRclassic
Application: Emergency stop
Safety door
Light grid
Mechanical service life: 10x 106 cycles
Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN61810-3
Electrical propertiesMaximum power dissipation for nominal condition: 3.72 W
Nominal operating mode: 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 VAC
Rated surge voltage/insulation: Basic insulation 4kV:
between all current paths and housing
Safe isolation, reinforced insulation 6kV:
between 13/14, 23/24, 33/34, and the remaining current paths
between 13/14, 23/24, 33/34 among one another
Input dataGeneral
Rated control circuit supply voltage US: 24 VDC -15% / +10%
Power consumption at US: typ. 3.72 W
Rated control supply current IS: typ. 155 mA
Inrush current: 200 mA (at US)
< 40 mA (with Us/Ix to S10)
< 150 mA (with Us/Ix to S12)
> -60 mA (with Us/Ix to S22)
< 40 mA (with Us/Ix to S34)
< 40 mA (with Us/Ix to S35)
Current consumption: < 40 mA (with Us/Ix to S10)
< 50 mA (with Us/Ix to S12)
> -40 mA (with Us/Ix to S22)
0 mA (with Us/Ix to S34)
< 5 mA (with Us/Ix to S35)
Voltage at input/start and feedback circuit: 24 VDC -15% / +10%
Filter time: 1 ms (at A1 in the event of voltage dips at Us)
max. 1.5 ms (at S10, S12; test pulse width)
7.5 ms (at S10, S12; test pulse rate)
Test pulse rate=5xTest pulse width
Typical response time: < 600 ms (automatic start)
< 70 ms (manual start)
Typ. starting time with Us: < 600 ms (when controlled via A1)
Typical release time: < 20 ms (when controlled via S11/S12 and S21/S22)
< 20 ms (when controlled via A1)
Concurrence: ∞
Recovery time: < 1 s
Maximum switching frequency: 0.5 Hz
Protective circuit: Surge protection; Suppressor diode
Max. permissible overall conductor resistance: approx. 22 Ω (Input and start circuits at US)
Operating voltage display: 1 x green LED
Status display: 4 x green LEDs
Output dataContact switching type: 5 enabling current paths
1 signaling current path
Contact material: AgSnO2
Maximum switching voltage: 250 V AC/DC (Observe the load curve)
Minimum switching voltage: 5 V AC/DC
Limiting continuous current: 6 A (N/O contact, pay attention to the derating)
6 A (N/C contact)
Maximum inrush current: 20 A (Δt100ms, undelayed contacts)
8 A (delayed contacts)
Inrush current, minimum: 10 mA
Sq. Total current: 55 A2 (observe derating)
Interrupting rating (ohmic load) max.: 144 W (24 V DC, τ = 0 ms)
288 W (48 V DC, τ = 0 ms)
110 W (110 V DC, τ = 0 ms, delayed contacts: 77W)
88 W (220 V DC, τ = 0 ms)
1500 VA (250 V AC, τ = 0 ms, delayed contacts: 2000VA)
Maximum interrupting rating (inductive load): 42 W (24 V DC, τ = 40 ms, delayed contacts: 48W)
42 W (48 V DC, τ = 40 ms, delayed contacts: 40W)
42 W (110 V DC, τ = 40 ms, delayed contacts: 35W)
42 W (220 V DC, τ = 40 ms, delayed contacts: 33W)
Switching capacity min.: 50 mW
Switching capacity (360/h cycles): 4 A (24VDC)
4 A (230 V AC)
Switching capacity (3600/h cycles): 2.5 A (24V (DC13))
3 A (230 V (AC15))
Output fuse: 10 A gL/gG (N/O contact)
6 A gL/gG (N/C contact)
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Push-in connection
Conductor cross section rigid: 0.2 mm² ... 1.5 mm²
Conductor cross section flexible: 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible, with ferrule, with plastic sleeve: 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross section flexible, with ferrule without plastic sleeve: 0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section AWG: 24 ... 16
Stripping length: 8 mm
DimensionsWidth: 45 mm
Height: 112 mm
Depth: 114.5 mm
Material specificationsHousing material: PBT
CharacteristicsSafety data
Stop category: 0
1
Safety data: ENISO13849
Category: 4 (Undelayed contacts)
3 (delayed contacts)
Performance level (PL): e (for delayed contacts PLd)
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL): 3 (for delayed contacts SIL2)
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL): 3 (for delayed contacts SIL2)
Safety data: ENIEC 62061
Safety Integrity Level (SIL): 3 (for delayed contacts SIL2)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -20°C ... 55°C (observe derating)
Ambient temperature (storage/transport): -40°C ... 70°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
Shock: 15g
Vibration (operation): 10Hz...150Hz, 2g
ApprovalsCE
Certificate: CE-compliant
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: IEC 60664-1
MountingMounting type: DIN rail mounting
Mounting position: any
Connection method: Push-in connection
Specifiche
ECLASSECLASS-11.0: 27371819
ECLASS-13.0: 27371819
ECLASS-12.0: 27371819
ETIMETIM 9.0: EC001449
UNSPSCUNSPSC 21.0: 39122200
Descrizione
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat. 4, PL e (EN ISO 13849), one- or two-channel operation, automatic or manual activation, 3 N/O contacts, 1 N/C contact, 2 N/O contacts with dropout delay of 0.2 s ... 300 s, pluggable Push-in terminal block
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Approvals_01810.pdf

Approvals_01811.pdf

Certification_00218.pdf

Certification_00336.pdf

Data_sheet_03978.pdf

Manufacturer_declaration_00586.pdf

Manufacturer_declaration_02370.pdf

Manufacturer_declaration_05474.pdf

Manufacturer_declaration_17024.pdf

Package_slip_01871.pdf

Technical_drawing_41665.pdf