Automazione Industriale

Meccatronica

Sicurezza Industriale

Componenti Quadri

Sensori e Sistemi di Visione

Pneumatica

Network e Comunicazione

Cavi Speciali

Software di progettazione

Accedi ai servizi

Entra nella tua area riservata

Accedi ai servizi

Entra nella tua area riservata

PHOENIX CONTACT 2981677
PHOENIX CONTACTNon disponibile

PSR-SCP- 24DC/URM4/4X1/2X2/B - Extension module

1-channel contact extension with TBUS interface, 4N/O contacts, 1N/C contact, 1confirmation current path, undelayed, Cat.4, PLe in accordance with ENISO13849, plug-in screw terminal blocks, width: 22.5mm
Cod. Articolo: 2981677
Cod. Fornitore: 2981677
PHOENIX CONTACT


Diminuisci la quantità
Aumenta la quantità
Caratteristiche Tecniche
Specifiche
Download
Caratteristiche Tecniche
Product propertiesProduct type: Safety relays
Product family: PSRclassic
Application: Extension module
Mechanical service life: approx. 107 cycles
Relay type: Electromechanical relay with force-guided contacts in accordance with IEC/EN61810-3
Electrical propertiesMaximum power dissipation for nominal condition: 1.01 W
Nominal operating mode: 100% operating factor
Air clearances and creepage distances between the power circuits
Rated insulation voltage: 250 V
Rated surge voltage/insulation: 4 kV / basic isolation (safe isolation, reinforced insulation and 6 kV between input circuit/N/C contacts and enabling current paths).
Input dataGeneral
Rated control circuit supply voltage US: 24 VDC
Voltage range with reference to US: 0.9 ... 1.1
Rated control supply current IS: 42 mA
Typical response time: 10 ms
Typical release time: 10 ms
Recovery time: 1 s
Protective circuit: Surge protection; Suppressor diode
Status display: Green LED
Output dataContact switching type: 4 enabling current paths
1 signaling current path
1 confirmation current path
Contact material: AgSnO2
Maximum switching voltage: 250 V AC/DC
Minimum switching voltage: 15 V AC/DC
Limiting continuous current: 6 A (N/O contact, DC1/AC1)
3 A (N/C contact)
Maximum inrush current: 6 A (N/O contact, DC1/AC1)
3 A (N/C contact)
Inrush current, minimum: 25 mA
Sq. Total current: 72 A2 (ITH2 = I12 + I22 + I32 + I42)
Interrupting rating (ohmic load) max.: 144 W (24 V DC, τ = 0 ms, N/C contact 61/62: 72 W)
288 W (48 V DC, τ = 0 ms, N/C contact 61/62: 144 W)
77 W (110 V DC, τ = 0 ms)
88 W (220 V DC, τ = 0 ms)
1500 VA (250 V AC, τ = 0 ms, N/C contact 61/62: 750 VA)
Maximum interrupting rating (inductive load): 48 W (24VDC, τ=40ms)
40 W (48 V DC, τ = 40 ms)
35 W (110 V DC, τ = 40 ms)
33 W (220 V DC, τ = 40 ms)
Switching capacity min.: 0.4 W
Switching capacity in accordance with IEC 60947-5-1: 5 A (DC13)
5 A (AC15)
Switching capacity (360/h cycles): 6 A (24VDC)
5 A (230 V AC)
Switching capacity (3600/h cycles): 3 A (24V (DC13))
3 A (230 V (AC15))
Output fuse: 10 A gL/gG NEOZED (N/O contact)
4 A gL/gG NEOZED (N/C contact)
Connection dataConnection technology
pluggable: yes
Conductor connection
Connection method: Screw connection
Conductor cross section rigid: 0.2 mm² ... 2.5 mm²
Conductor cross section flexible: 0.2 mm² ... 2.5 mm²
Conductor cross-section AWG: 24 ... 12
Stripping length: 7 mm
Screw thread: M3
DimensionsWidth: 22.5 mm
Height: 99 mm
Depth: 114.5 mm
Material specificationsHousing material: Polyamide
CharacteristicsSafety data
Stop category: 0
Safety data: ENISO13849
Category: 4 (In conjunction with suitable evaluating device)
Performance level (PL): e (In conjunction with suitable evaluating device)
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL): 3 (In conjunction with suitable evaluating device)
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL): 3 (In conjunction with suitable evaluating device)
Safety data: ENIEC 62061
Safety Integrity Level (SIL): 3 (In conjunction with suitable evaluating device)
Environmental and real-life conditionsAmbient conditions
Degree of protection: IP20
Min. degree of protection of inst. location: IP54
Ambient temperature (operation): -20°C ... 55°C
Ambient temperature (storage/transport): -40°C ... 70°C
Maximum altitude: ≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport): 75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation): 75 % (on average, 85% infrequently, non-condensing)
Standards and regulationsAir clearances and creepage distances between the power circuits
Standards/regulations: IEC 60947-1
MountingMounting type: DIN rail mounting
Mounting position: any
Connection method: Screw connection
Specifiche
ECLASSECLASS-11.0: 27371819
ECLASS-12.0: 27371819
ECLASS-13.0: 27371819
ETIMETIM 9.0: EC001449
UNSPSCUNSPSC 21.0: 39122200
Download
PER SCARICARE I DOCUMENTI E' NECESSARIO EFFETTUARE L'ACCESSO AL SITO

Application_note_00183.pdf

Approvals_01216.pdf

Approvals_01217.pdf

Certification_00176.pdf

Certification_00342.pdf

Data_sheet_03982.pdf

Data_sheet_03983.pdf

Manufacturer_declaration_00792.pdf

Manufacturer_declaration_01403.pdf

Manufacturer_declaration_02131.pdf

Manufacturer_declaration_02204.pdf

Manufacturer_declaration_05474.pdf

Manufacturer_declaration_17033.pdf

Package_slip_01888.pdf

Package_slip_01889.pdf

Technical_drawing_41674.pdf